Mohsen Siami

Mohsen Siami

Auto-generated profile, based on publicly available information

Mohsen Siami

Iran Power Generation, Transmission & Distribution Management Company (TAVANIR), Tehran Iran (the Islamic Republic of) 6467-14155

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
MSMohsen Siami
Mohsen Siami
DKDavood Arab Khaburi
Davood Arab Khaburi
AAAlireza Abbaszadeh
Alireza Abbaszadeh
Jose RodriguezJose Rodriguez
Jose Rodriguez
The predictive control method deals with the prediction of the motor behavior based on a mathematical model of the motor. This model is dependent on the motor parameters. However, these parameters may not match with their actual values due to the measurement error or they may change during the operation of the motor. All these uncertainties and model inexactitude lead to inaccurate prediction of the motor behavior and deteriorate the performance of the predictive algorithm. This paper presents an extension of the predictive current control (PCC) method to improve the prediction accuracy for a permanent-magnet synchronous motor (PMSM). The proposed strategy not only reduces the current ripple but also improves the robustness of the system against parameter uncertainties. Simulation and experimental results that confirm the good performance of the proposed method are presented.

3 April 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SSSeyyed Mohammad Seyyedzadeh
Seyyed Mohammad Seyyedzadeh
SMSobhan Mohamadian
Sobhan Mohamadian
MSMohsen Siami
Mohsen Siami
ASAbbas Shoulaie
Abbas Shoulaie
In self-commissioning, motor parameters are estimated by analyzing the measured currents and voltages. At standstill, the obtained voltages are low because the motor back-EMF is zero. Therefore, the inverter nonlinearities are comparable with the estimated voltages and it is necessary to compensate for the nonlinearities. In order to model the inverters nonlinear characteristics, dc current test is conventionally used. However, this test results in a nonlinear equation that contains nonlinearities of two phases. Hence, a numerical solution must be carried out to achieve each inverter phase nonlinearity. Moreover, three-phase symmetry of the inverter is necessary in conventional methods making them inappropriate to characterize the nonlinearities of multilevel inverters with bypassed cells. This paper proposes a novel characterization algorithm with no numerical solutions applied for motor self-commissioning of VSI-fed drives. The proposed method, not only improves the fundamental and THD of calculated phase voltage by 42% and 6% at low currents, respectively, but also it is suitable for characterizing the nonlinearities of multilevel inverters with bypassed cells. A prototype of a five-level cascaded H-bridge inverter and a two-level inverter feeding a 2.2-kW three-phase induction motor is provided to verify the superiority of the proposed method specifically at very low currents.

16 May 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
MSMohsen Siami
Mohsen Siami
MAMohammad Amiri
Mohammad Amiri
HSHamed Kiani Savadkoohi
Hamed Kiani Savadkoohi
RRRamtin Rezavandi
Ramtin Rezavandi
SVSaeed Valipour
Saeed Valipour
Predictive control is emerging as an attractive technique for control of matrix converters. Compared with the classical linear controllers, predictive control needs a shorter control interval to reach the same performance. But, the implementation of predictive control for matrix converters involves a large amount of calculation which is an obstacle for their applications. This paper proposes a simplified predictive control of torque and input current of a permanent magnet synchronous motor (PMSM) fed by a matrix converter which effectively reduces the calculations in comparison with conventional approach without touching the quality of control performance. The experimental results are presented to verify the validity of the proposed method.

1 November 2013 in Journal of Electrical Engineering
Verified
Journal Article
Closed access
PDF file
MSMohsen Siami
Mohsen Siami
SGS. Asghar Gholamian
S. Asghar Gholamian
MYMosayeb Yousefi
Mosayeb Yousefi
This paper presents a comparative study between direct torque control (DTC) and predictive torque control (PTC) of Axial Flux Permanent magnet Machines (AFPM). In conventional DTC method for permanent magnet machines, only six actives voltage vectors of inverter are used to control torque and flux of machine. But in predictive torque control, in addition to six active voltage vectors, zero voltage vectors are used to control machine. So number of voltage vectors to control AFPM increases that leads to lower ripple of torque and flux. In predictive torque control, the response of torque and flux are computed for all possible switching states of inverter at every sample time according to discrete time model of machine, and then the switching state that optimizes ripple of torque and flux, will be applied in next discrete-time interval. Simulation results which compare the results of implementation of both methods and confirm the good performance of the proposed predictive torque control are presented.