Teresa Mendes de Almeida

Teresa Mendes de Almeida

Auto-generated profile, based on publicly available information

Teresa Mendes de Almeida

Inst. de Eng. de Sist. e Comput.-R&D (INESC-ID), Lisbon, Portugal

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2009 in Sensors
Verified
Journal Article
Open access
PDF file
JGJosé Germano
José Germano
VRVerónica C. Martins Romão
Verónica C. Martins Romão
Filipe Arroyo CardosoFilipe Arroyo Cardoso
Filipe Arroyo Cardoso
TATeresa M. Almeida
Teresa M. Almeida
LSLeonel Sousa
Leonel Sousa
MPMoisés S. Piedade
Moisés S. Piedade
This paper presents a prototype of a platform for biomolecular recognition detection. The system is based on a magnetoresistive biochip that performs biorecognition assays by detecting magnetically tagged targets. All the electronic circuitry for addressing, driving and reading out signals from spin-valve or magnetic tunnel junctions sensors is implemented using off-the-shelf components. Taking advantage of digital signal processing techniques, the acquired signals are processed in real time and transmitted to a digital analyzer that enables the user to control and follow the experiment through a graphical user interface. The developed platform is portable and capable of operating autonomously for nearly eight hours. Experimental results show that the noise level of the described platform is one order of magnitude lower than the one presented by the previously used measurement set-up. Experimental results also show that this device is able to detect magnetic nanoparticles with a diameter of 250 nm at a concentration of about 40 fM. Finally, the biomolecular recognition detection capabilities of the platform are demonstrated by performing a hybridization assay using complementary and non-complementary probes and a magnetically tagged 20mer single stranded DNA target.

13 November 2006 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
MPMoiss Piedade
Moiss Piedade
LSLeonel Sousa
Leonel Sousa
TATeresa Mendes de Almeida
Teresa Mendes de Almeida
JGJos Germano
Jos Germano
BCBertinho D'Andrade da Costa
Bertinho D'Andrade da Costa
Filipe Arroyo CardosoFilipe Arroyo Cardoso
Filipe Arroyo Cardoso
This paper presents a hand-held microsystem based on new fully integrated magnetoresistive biochips for biomolecular recognition (DNA hybridization, antibody antigen interaction, etc.). Magnetoresistive chip surfaces are chemically treated, enabling the immobilization of probe biomolecules such as DNA or antibodies. Fluid handling is also integrated in the biochip. The proposed microsystem not only integrates the biochip, which is an array of 16times16 magnetoresistive sensors, but it also provides all the electronic circuitry for addressing and reading out each transducer. The proposed architecture and circuits were specifically designed for achieving a compact, programmable and portable microsystem. The microsystem also integrates a hand-held analyzer connected through a wireless channel. A prototype of the system was already developed and detection of magnetic nanoparticles was obtained. This indicates that the system may be used for magnetic label based bioassays

10 November 2009 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TATeresa Mendes de Almeida
Teresa Mendes de Almeida
MPMoisés S. Piedade
Moisés S. Piedade
LSLeonel Sousa
Leonel Sousa
JGJosé Germano
José Germano
PLPaulo A. C. Lopes
Paulo A. C. Lopes
PFPaulo Freitas*
Paulo Freitas*
A fully integrated biochip based on a 16 × 16 scalable matrix structure of aluminum oxide magnetic tunnel junctions (MTJs) and thin-film diodes (TFDs of hydrogenated amorphous silicon) was fabricated and included as the biosensor of a portable handheld microsystem developed for biomolecular recognition detection using magnetic labels [deoxyribonucleic acid (DNA) hybridization, antibody antigen interaction, etc.]. The system uses magnetic field arraying of magnetically tagged biomolecules and can potentially be used to detect single or few biomolecules. Each biosensor matrix node is the series between a TFD (p-i-n or Schottky-barrier type) and an MTJ. In this paper, this matrix basic cell biosensor element is completely characterized and modeled. Experimental measured data are provided and compared with the proposed theoretical models results. It is shown that the diode may be used both as the matrix switching device and as an in-site temperature sensor and that the MTJ may act as the magnetoresistive sensor for detecting the fringe field of immobilized magnetic markers. Therefore, the fabricated fully integrated biochip included in the developed handheld microsystem may be used for biomolecular recognition.

14 October 2008 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PLPaulo A. C. Lopes
Paulo A. C. Lopes
JGJosé Germano
José Germano
TATeresa Mendes de Almeida
Teresa Mendes de Almeida
LSLeonel Sousa
Leonel Sousa
MPMoisés S. Piedade
Moisés S. Piedade
PFPaulo Freitas*
Paulo Freitas*
This paper proposes techniques for the extraction of biological information in a recently developed handheld biochip-based microsystem. The microsystem is based on a magnetoresistive array biochip composed of a number of sensing sites with magnetic tunneling junctions (MTJ) and diodes. Different techniques are addressed to drive the MTJs with different types of signals. Different filtering strategies that allow the recovery of biological signals from the noise without overly increasing either the time required for accessing the sensors or the power consumption of the board are proposed. Finally, new techniques and algorithms are proposed to deal with the variability of the fabrication parameters of the MTJ and the diodes. Experiments with the system in a setup to detect actual biological signals are presented with encouraging results.

4 May 2007
Verified
Book Chapter
Closed access
PDF file
LSLeonel Sousa
Leonel Sousa
MPM. Piedade
M. Piedade
JGJ. Germano
J. Germano
TAT. Almeida
T. Almeida
PLP. Lopes
P. Lopes
PFPaulo Freitas*
Paulo Freitas*

1 June 2006
Verified
Conference Paper
Closed access
BCB. A. Costa
B. A. Costa
JLJoao M Lemos
Joao M Lemos
MPM. S. Piedade
M. S. Piedade
LSLeonel Sousa
Leonel Sousa
TAT. Almeida
T. Almeida
Filipe Arroyo CardosoFilipe Arroyo Cardoso
Filipe Arroyo Cardoso
This paper describes the work on temperature modelling of an Electronic Detection Cell (EDC) for DNA analysis. The EDC is part of a biochip which is under development at INESC. The main goal of the project is to build a hand-held biochip with several sites for running simultaneous detection experiments with independent temperature profiles. The basic DNA detection electronic cell comprises a Thin Film Diode (TFD) in series with a Magnetic Resistive Tunnel Junction (MRTJ). The role of the MRTJ is to detect the presence of bio-molecules using magnetic bides. The TFD is to be used as a temperature sensor, to give information about the temperature at which the hybridization process is developing and also as a electronic selector of the hybridization site, which are arranged in a matrix. Both the TFD and MRTJ will dissipate power but the main source of heat is a current line which is used to attract the bides to the MRTJ. Because of the structure of the biochip one must understand how heat diffuses between the heater and the hybridization site, and one must characterize the temperature distribution between the hybridization site, temperature sensor and the power input