Adam C. Francis

Adam C. Francis

Auto-generated profile, based on publicly available information

Adam C. Francis

Victoria University of Wellington

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2016 in Advanced Optical Materials
Verified
Journal Article
Closed access
PDF file
PRPhilipp Reineck
Philipp Reineck
AFAdam Francis
Adam Francis
AOAntony Orth
Antony Orth
DLDesmond Wai Mo Lau
Desmond Wai Mo Lau
RNReece David Valmont Nixon‐Luke
Reece David Valmont Nixon‐Luke
BGBrant C. Gibson
Brant C. Gibson

27 July 2023 in Superconductivity
Verified
Journal Article
Open access
AFA.C. Francis
A.C. Francis
SVS. Venuturumilli
S. Venuturumilli
DMD.A. Moseley
D.A. Moseley
SCS. Claridge
S. Claridge
BLB. Leuw
B. Leuw
CBC.W. Bumby
C.W. Bumby

13 November 2023 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
SVS. Venuturumilli
S. Venuturumilli
AFA. C. Francis
A. C. Francis
APA. E. Pantoja
A. E. Pantoja
RTR. W. Taylor
R. W. Taylor
JBJ. M. Brooks
J. M. Brooks
CBC. W. Bumby
C. W. Bumby
A high temperature superconducting (HTS) dynamo is a type of device known as a “flux pump” that can inject DC into a closed superconducting circuit. Here, we report experimental results from a variable-temperature dynamo-type HTS flux pump operated within a cryo-cooled chamber. This device employs a “continuous stator” topology, whereby an HTS “coated conductor” is wrapped to form a cylinder around a mechanical rotor such that applied flux from the rotor magnet must always penetrate the stator. This leads to a high current device that can inject >1 kA into a series-connected HTS coil at 53 K. The open-circuit DC output voltage (Voc) from this HTS dynamo has been studied at stator temperatures between 35 and 95 K and attained a maxima at a temperature ∼5 K lower than the stator Tc. At lower temperatures, Voc decreases and falls to zero below ∼40 K. This non-intuitive effect is found to be due to flux-screening by critical currents flowing with the HTS stator, which increase with decreasing temperature. These shielding currents prevent flux from penetrating the HTS stator and, hence, reduce the magnitude of locally induced emf (and thus DC output) within the HTS film. A key implication of these results is that all magnetically driven HTS flux pumps should be operated at temperatures well above their flux-screening point, and this consideration must be taken into account for future designs of multi-kA class HTS flux pumps.

26 February 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JRJames H.P. Rice
James H.P. Rice
AFAdam C. Francis
Adam C. Francis
BMBen P.P. Mallett
Ben P.P. Mallett
DMDominic A. Moseley
Dominic A. Moseley
APAlexander Petrov
Alexander Petrov
RBRodney Badcock
Rodney Badcock
High-current flux pumps are an enabling technology for high-temperature superconducting (HTS) magnets operating in a quasi-persistent current mode (qPCM). For fusion energy specifically, flux pumps must be capable of delivering more than 10 kA of DC output to a superconducting magnet. Recent HTS flux pumps have yet to achieve more than 1–3 kA of current. In this report, we present progress towards a 10 kA HTS flux pump using the transformer-rectifier circuit topology at the Paihau-Robinson Research Institute. A 10 kA test solenoid has been designed and the fabrication has been commenced. The main requirements of the rectifier switches and transformer have been identified and evaluated, with a circuit simulation demonstrating 10 kA of output expected in under 15 s, with a current ripple of only 0.33%. Finally, a method of low-resistance solder joint fabrication using indium-foil is validated.

4 November 2024 in Superconductor Science and Technology
Verified
Journal Article
Open access
AFA C Francis
A C Francis
DMD A Moseley
D A Moseley
JCJ Clarke
J Clarke
RBRodney Badcock
Rodney Badcock
Superconducting power supplies commonly known as flux pumps are becoming viable products in various industries. In this work we investigate magnetically switched ( J c ( B ) ) half-wave transformer rectifier flux pumps (TRFPs) via a simulation previously validated against an experimental system. Upgrades to the model are introduced, namely the transition to a fully hysteretic transformer reluctance model and the introduction of a conduction cooling thermal model. The conduction cooling model allows direct comparison between liquid cryogen and conduction cooled systems, highlighting the distinct variations in response. This study focuses on parameter sweeps over some of the most important aspects of a TRFP such as; input power, cooling paths and switch length. The findings from these variable sweeps shed light on how to best design the different aspects of a TRFP for most applications and the conclusions drawn throughout this work can be applied to most TRFP types. Some of the major findings from this work are; i. the need for dedicated cooling busses in TRFP switches, ii. that increased switch lengths increase voltage generation but negatively impact cooling effectiveness iii. that the reduction of the metallic coatings surrounding commercial coated conductors results in larger switch voltages.

14 June 2021 in Applied Optics
Verified
Journal Article
Closed access
AFAdam Francis
Adam Francis
CTChhayly Tang
Chhayly Tang
EREric C. Le Ru
Eric C. Le Ru
We present a rigorous approach for measuring the throughput of an integrating sphere, from which the so-called sphere multiplier M can be derived. The critical ingredients of this approach are: (i) the transmitted power is measured at the base of an integrating port to avoid non-ideal port effects associated with reflections on the port wall; (ii) to implement this last point, optical fibers are used for light collection, providing a well-defined collection area and numerical aperture; (iii) the angular-dependent fiber throughput and detector sensitivity are determined experimentally and accounted for. We demonstrate in particular that a more realistic theory, accounting for the propagation of skew rays through the fiber, is needed to quantitatively model the fiber effect on the measured sphere throughput. We show experimentally that failure to fulfill these three points produces erroneous results, by as much as 50%. With an accurate experimentally derived sphere multiplier, agreement with theory is then obtained only if realistic ports (with non-zero reflectivity) are assumed. This provides experimental evidence for recent theoretical predictions of the importance of realistic ports [Tang et al., Appl. Opt. 57, 1581 (2018)APOPAI 0003-6935 10.1364/AO.57.001581 ]. Using the same experimental techniques, we also present clear experimental proof of two other predictions from that study: that the angular distribution exiting the port is strongly altered and that the overall port transmittivity is drastically reduced for high aspect ratio ports. This work will provide a solid basis for future quantitative measurements of absolute throughput and for further developments of the theory of integrating spheres.