Wan-Gil Jung

Dr. Wan-Gil Jung

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2025 in Applied Surface Science
Verified
Journal Article
Closed access
BYByung Sun Yoon
Byung Sun Yoon
JYJae-Rang Youn
Jae-Rang Youn
WJWan-Gil Jung
Wan-Gil Jung
GPGwan-Joong Park
Gwan-Joong Park
DKDa-Bin Kang
Da-Bin Kang
CKChang Hyun Ko
Chang Hyun Ko

9 February 2024 in Physica Scripta
Verified
Journal Article
Closed access
WMWon-Jin Moon
Won-Jin Moon
SYSeul Gi Yu
Seul Gi Yu
YKYang Soo Kim
Yang Soo Kim
BPByung-Kyu Park
Byung-Kyu Park
WJWan-Gil Jung
Wan-Gil Jung
HSHo-Jun Song
Ho-Jun Song
Elemental quantification of several single crystalline TEM samples of intermediate thickness range that cannot be quantified by the thin-film approximation method and the ZAF correction were investigated using wedge-shaped samples of known thickness fabricated by the FIB technique. ‘Thickness factor (T F )’ and ‘Thickness correction coefficient (T C )’ were proposed as error correction items of ‘thin-film approximation method’ to minimize the quantitative error that occurs when quantifying samples of intermediate thickness with TEM-EDS. As the result of T F correction, the quantification error in an Al2O3 TEM sample by TEM-EDS was reduced from about 52.15% to less than 3.28 (± 2.57) % by the correction of only one time. The self-absorption corrected line profiles and self-absorption corrected elemental mapping images in TEM samples of intermediate thickness range were also obtained by T F correction. As an example of application by T F correction, we proposed a novel method measuring thin-film thickness in normal TEM without the EELS system. The T F correction technique is a unique method to overcome the limitation of EDS quantification in the intermediate thickness range. This technique can effectively quantify characteristic x-ray lines less than 1,000 eV in the sample having intermediate thickness ranges using the conventional TEM-EDS system. It is expected to contribute significantly to understanding various characteristics or material nature related to material composition and sample thickness in nanomaterials because it provides more precise quantitative analysis information than current commercial EDS systems.

8 February 2025 in Applied Surface Science Advances
Verified
Journal Article
Open access
JTJiayi Tang
Jiayi Tang
OSOkkyun Seo
Okkyun Seo
JKJaemyung Kim
Jaemyung Kim
IGIbrahima Gueye
Ibrahima Gueye
Loku Singgappulige Rosantha KumaraLoku Singgappulige Rosantha Kumara
Loku Singgappulige Rosantha Kumara
OSOsami Sakata
Osami Sakata

1 August 2023 in Research Square
Verified
Preprint
Open access
PDF file
WMWon-Jin Moon
Won-Jin Moon
SYSeul Gi Yu
Seul Gi Yu
YKYang Soo Kim
Yang Soo Kim
BPByung-Kyu Park
Byung-Kyu Park
WJWan-Gil Jung
Wan-Gil Jung
HSHo-Jun Song
Ho-Jun Song
Elemental quantification of several single crystalline TEM samples of intermediate thickness range that cannot be quantified by the thin-film approximation method and the ZAF correction were investigated using wedge-shaped samples of known thickness fabricated by the FIB technique. "Thickness factor (TF)" and "Thickness correction coefficient (TC)" were proposed as error correction items of "thin-film approximation method" to minimize the quantitative error that occurs when quantifying samples of intermediate thickness with TEM-EDS. As the result of TF correction, the quantification error in an Al2O3 TEM sample by TEM-EDS was reduced from about 52.15% to less than 3.28 (± 2.57) % by the correction of only one time. The self-absorption corrected line profiles and self-absorption corrected elemental mapping images in TEM samples of intermediate thickness range were also obtained by TF correction. As an example of application by TF correction, we proposed a novel method measuring thin-film thickness in normal TEM without the EELS system. The TF correction technique is a unique method to overcome the limitation of EDS quantification in the intermediate thickness range. This technique can effectively quantify characteristic X-ray lines less than 1,000 eV in the sample having intermediate thickness ranges using the conventional TEM-EDS system. It is expected to contribute significantly to understanding various characteristics or material nature related to material composition and sample thickness in nanomaterials because it provides more precise quantitative analysis information than current commercial EDS systems.

30 June 2023 in Korean Journal of Dental Materials
Verified
Journal Article
Closed access
HSHo-Jun Song
Ho-Jun Song
Yeong-Joon ParkYeong-Joon Park
Yeong-Joon Park
WMWon-Jin Moon
Won-Jin Moon
WJWan-Gil Jung
Wan-Gil Jung
SCSeon-Shin Cho
Seon-Shin Cho
TYTaek-Rim Yoon
Taek-Rim Yoon
본 연구에서는 우수한 생체적합성과 부식저항성 그리고 기계적 특성을 갖는 Ti6Al4V 합금을 선택적 레이저 용융(selective laser melting; SLM)법을 이용하여 시편을 제조하였다(Ti6Al4V-AS군). 이 시편들을 진공전기로를 이용하여 950℃와 550℃에서 열처리를 수행하였다(Ti6Al4V-HT군). 열처리 전후 합금 시편들의 기계적 특성, 금속 조직 형상, 결정구조 및 화학적 특성을 분석하였다.BR Ti6Al4V-AS 합금은 높은 항복강도와 낮은 연신율 값을 보여주었다. 금속 조직 이미지에서 침상의 결정립들이 관찰되었으며, 결정구조 분석 결과 α′-Ti 상이 지배적이었다. 열처리를 수행한 Ti6Al4V-HT 합금은 항복강도 값이 낮아지고 연신율은 증가하였다. 또한 주상 형의 결정립들이 배열된 층상 구조의 조직이 관찰되었으며, α+β-Ti 상이 형성되었고, 결정성은 증가하였다. 각 시편들의 화학적 조성을 분석한 결과, Ti6Al4V-AS 시편이 Ti6Al4V-HT 시편에 비하여 높은 탄소의 함량을 함유하고 있었으며, 이 탄소의 함량이 Ti6Al4V-AS 시편의 α′- 상의 형성과 높은 강도와 및 낮은 연신율에 영향을 미치는 것으로 해석되었다. Ti6Al4V-HT 시편의 경우 전체적인 탄소의 함량은 낮았지만, 국소적으로 α-상 영역에 탄소의 함량이 높았다. 따라서 SLM법을 이용한 Ti6Al4V 시편 제조 시 탄소 가스의 혼입을 효과적으로 제어할 필요가 있음을 알 수 있었다.