Fabio Bertequini Leao

Fabio Bertequini Leao

Auto-generated profile, based on publicly available information

Fabio Bertequini Leao

Electrical Engineering, Sao Paulo State University-UNESP, Ilha Solteira, Sao Paulo Brazil 15385-000

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2015 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
RRRubén Romero
Rubén Romero
JFJohn Franco
John Franco
FLFabio B. Leao
Fabio B. Leao
MRMarcos J. Rider
Marcos J. Rider
ESEliane S. de Souza
Eliane S. de Souza
This paper presents a comprehensive mathematical model to solve the restoration problem in balanced radial distribution systems. The restoration problem, originally modeled as mixed integer nonlinear programming, is transformed into a mixed integer second-order cone programming problem, which can be solved efficiently using several commercial solvers based on the efficient optimization technique family branch and bound. The proposed mathematical model considers several objectives in a single objective function, using parameters to preserve the hierarchy of the different objectives: 1) maximizing the satisfaction of the demand, 2) minimizing the number of switch operations, 3) prioritizing the automatic switch operation rather than a manual one, and 4) prioritizing especial loads. General and specialized tests were carried out on a 53-node test system, and the results were compared with other previously proposed algorithms. Results show that the mathematical model is robust, efficient, flexible, and presents excellent performance in finding optimal solutions.

16 April 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
RBRicardo Fonseca Buzo
Ricardo Fonseca Buzo
HBHenrique Molina Barradas
Henrique Molina Barradas
FLFabio Bertequini Leao
Fabio Bertequini Leao
This paper presents an innovative method for fault location in distribution networks based on classical circuit analyses. Two synchronized and few nonsynchronized pre- and during-fault voltages are required at few buses along with the impedance matrix. A new impedance matrix manipulation procedure is proposed so that the distribution system is investigated in partitions across multiple subsystems. This procedure allows the fault location process to be performed by solving systems of determined equations, making the method more technically accessible. The fault is located by analyzing the voltage sag at the terminal-bus of each subsystem separately. The proposed method is validated on the IEEE 33-bus, 12.66 kV distribution system with/without distributed generation (DG). Simulation results show the robustness and accuracy of the method under several pre- and during-fault scenarios and measurements errors.

1 August 2016 in Electric Power Systems Research
Verified
Journal Article
Closed access
DPDiego Piasson
Diego Piasson
ABAndré A.P. Bíscaro
André A.P. Bíscaro
FLFábio B. Leão
Fábio B. Leão
JMJosé Roberto Sanches Mantovani
José Roberto Sanches Mantovani

31 October 2010 in Electric Power Systems Research
Verified
Journal Article
Closed access
FLFábio Bertequini Leão
Fábio Bertequini Leão
RPRodrigo A.F. Pereira
Rodrigo A.F. Pereira
JMJose Roberto Sanches Mantovani
Jose Roberto Sanches Mantovani

1 December 2014 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
FLFábio Bertequini Leão
Fábio Bertequini Leão
RPRodrigo A.F. Pereira
Rodrigo A.F. Pereira
JMJose Roberto Sanches Mantovani
Jose Roberto Sanches Mantovani

7 February 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
RBRicardo Fonseca Buzo
Ricardo Fonseca Buzo
LOLuis Carlos Origa de Oliveira
Luis Carlos Origa de Oliveira
FLFabio Bertequini Leão
Fabio Bertequini Leão
This paper proposes an innovative method for dimensioning and designing the zero-sequence electromagnetic filter applied to three-phase four-wire distribution power systems. As premises, the optimum ratio between zero-sequence and positive-sequence impedances of the filter must be established in order to potentiate the filtering percentage of zero-sequence currents and ensure the quality of the supply system displacement power factor. The calculations are based on the sequential harmonic transmittances of the equivalent circuit reduced to the coupling point of the electromagnetic filter. To validate the proposed method, the results obtained with the application of the electromagnetic filter designed in a test system using the MATLAB software are compared to the results of the system modeled in the PSIM software.