18 April 2022 in IEEE Sensors Journal
Powered intelligent lower limb prostheses have been gaining interest as they provide functionality for walking on different terrains. This study proposes a hierarchical planner for intelligent lower limb prostheses based on sensor fusion and a central pattern generator (CPG). Electromyographic (EMG) and inertial measurement unit (IMU) signals were recorded and fused in the feature and decision levels. The high-level planner consists of cascade classifiers with a gait phase dependence. A secondary classifier for each stand phase and swing phase was developed to recognize five gait patterns. The mid-level planner was designed as a walking frequency estimator based on the Newton method. The low-level planner incorporates the CPG models, achieving the planning of lower limb joint trajectories. The proposed layered planner can recognize the users’ walking intention and gait speed in real-time, ensuring coordination between the joints of both legs. Eight healthy subjects were recruited, and the average accuracy of motion pattern recognition reached 99.13% and 99.39% for the standing and swing phases, respectively. The relative root mean square error (RMSE) of the walking frequency estimate was 2.3% under approximately 3.5 m/s gait speed. The promising results indicate that this method effectively predicts the continuous joint angle for lower limb prostheses.
14 March 2022 in IEEE/ASME Transactions on Mechatronics
Powered exoskeletons have global trends in broad applications, such as rehabilitation and human strength amplification in industry, military, and activities of daily livings. The motion intention of the exoskeleton wearer can be obtained using the interaction force at the physical human-machine interface. This article implements joint torque sensors in a custom-made cable-driven exoskeleton. The model of the torque sensor signal is established to extract the human-exoskeleton interaction (HEI) torque, which can be used to predict the human upper-limb motion intention. To accurately decouple the HEI torque from other components in the torque sensor signal, a nonlinear numerical friction model composed of the cable and joint parts is investigated based on the LuGre friction model. A protocol for parameter identification of the proposed friction model is verified experimentally. Furthermore, a coefficient combining the two friction models is designed for antagonistic directions in a joint to account for the bidirectional cable drive's backlash and hysteresis characteristics. Owing to this coefficient, the error of the friction model is reduced by approximately 90% during motion direction change. Finally, the accuracy of the torque sensor model is verified experimentally, and the root-mean-square error (RMSE) is about 0.038 N·m (2.8%). The RMSE of extracted interaction torque is about 0.25 N·m (8.1%). This article validates the feasibility of extracting HEI torque via a torque sensor implemented in the upper-limb exoskeleton, which can promote the development of new generations of upper-limb exoskeleton for active rehabilitation or assistance and research on intuitive control of exoskeleton in future.
24 April 2020 in IEEE Transactions on Medical Robotics and Bionics
The number of patients with motor dysfunction has increased rapidly over the past decade, in part due to the overall aging of society and the prevalence of neuromuscular disorders. To assist the upper limb in activities of daily livings, we have developed a wearable, portable and hybrid system with multi-degrees of freedom (DOFs). This novel hybrid system combined functional electrical stimulation (FES) with exoskeletons. A two-DOF shoulder exoskeleton, a wearable sleeve with FES electrodes, and a five-DOF hand robotic exoskeleton worked together to facilitate assistance in all of the upper limb joints: shoulder, elbow, wrist, and fingers. A ‘divide and rule’ strategy was adopted to utilize the relative merits of FES and exoskeletons according to different motion characteristics of upper limb joints. A finite state machine was developed as a high-level controller that issued commands to the real-time embedded controllers. Some functional movements of upper limb could be realised by a sequence of basic movements using the proposed system. The assistance performance of the exoskeleton was evaluated by electromyographic (EMG) signals, and the feasibility of this system was successfully verified by a drinking task.
9 May 2024 in Journal of Energy Storage
29 December 2023 in IEEE Transactions on Biomedical Engineering
Surface electromyography (sEMG) signals are crucial in developing human-machine interfaces, as they contain rich information about human neuromuscular activities. Objective : The real-time, accurate detection of muscle activation onset (MAO) is significant for EMG-triggered control strategies in embedded applications like prostheses and exoskeletons. Methods : This paper investigates sEMG signals using the generalized autoregressive conditional heteroskedasticity (GARCH) model, focusing on variance. A novel feature, the likelihood of conditional heteroskedasticity (LCH) extracted from the maximum likelihood estimation of GARCH parameters, is proposed. This feature effectively distinguishes signal from noise based on heteroskedasticity, allowing for the detection of MAO through the LCH feature and a basic threshold classifier. For online calculation, the model parameter estimation is simplified, enabling direct calculation of the LCH value using fixed parameters. Results : The proposed method was validated on two open-source datasets and demonstrated superior performance over existing methods. The mean absolute error of onset detection, compared with visual detection results, is approximately 65 ms under online conditions, showcasing high accuracy, universality, and noise insensitivity. Conclusion : The results indicate that the proposed method using the LCH feature from the GARCH model is highly effective for real-time detection of muscle activation onset in sEMG signals. Significance : This novel approach shows great potential and possibility for real-world applications, reflecting its superior performance in accuracy, universality, and insensitivity to noise.