This paper addresses the problem of sustainability in remediation, retrofit, and seismic upgrading of historic masonry structures. Different rehabilitation techniques and some successful applications throughout the Balkans and Italy are described, with particular emphasis to the shear reinforcement of wall panels. The selected techniques aim at improving the seismic performance, preserving the structures for future generations, having the least impact in altering the architectural and heritage values, as well as being sustainable, in terms of reduced carbon dioxide emissions, reversibility, and low energy consumption. The use of cross-laminated timber (CLT), natural fibers, and fiber-reinforced Polymers (FRP) jacketing with natural lime coatings are discussed. The paper concludes by summarizing key successes of the proposed rehabilitation solutions in conservation engineering and suggests areas in which these could be used with great advantage.
The aim of this work was to develop and validate an experimental methodology suitable for analysing on-site the behaviour of fibre-reinforced wooden structures. The proposed measurement method is based on the application of fibre Bragg grating (FBG) strain sensors. An analysis of adhesive behaviour was performed preliminarily, which provided indications for choosing the type of adhesive and for the fibre bonding length in accordance with the volume of measurement. The first series of tests was carried out on wood samples to verify the coupling between the measuring sensor and the wood support when the latter is subject to mechanical stresses. The second investigation was done on site to test the behaviour of a historical wood floor before and after reinforcement by means of a series of tests performed using optical fibres with the Bragg grating. The optical fibre system measurements were compared to those obtained using a laser vibrometer, a measurement system of proven stability and precision. The comparison makes it possible to confirm the validity of the results and the reliability of the system for the monitoring of historic wooden structures.
This paper investigates the influence of adding vegetal fibers on thermal and acoustic performance based on natural hydraulic lime. Mortar samples with 10% weight of vegetal fibers were fabricated adding water to obtain easily workable mortars with good consistency; their performance was compared to mortar samples without vegetal fibers. The fibers were of different types (rice husk, spelt bran, and Khorasan (turanicum) wheat chaff) and size (as-found and ground form). Thermal performance was measured with the Small Hot Box experimental apparatus. Thermal conductivity was reduced in the 1–11% range (with Khorasan wheat chaff and rice husk); no significant reduction was found with spelled bran in the mixture. When ground, fibers were characterized by both good thermal and acoustic absorption performance; a reduction of 6–22% in thermal conductivity λ was achieved with spelled bran (λ = 0.64 W/mK) and rice husks (λ = 0.53 W/mK), whereas the Khorasan wheat chaff had the highest sound absorption average index (0.38). However, the addition of fibers reduced sound insulation properties due to their low weight densities. This reduction was limited for rice husks (transmission loss value was only 2 dB lower than the reference).
The article presents a hybrid monitoring technique for the measurement of the deformation field. The goal is to obtain information about crack propagation in existing structures, for the purpose of monitoring their state of health. The measurement technique is based on the capture and analysis of a digital image set. Special markers were used on the surface of the structures that can be removed without damaging existing structures as the historical masonry. The digital image analysis was done using software specifically designed in Matlab to follow the tracking of the markers and determine the evolution of the deformation state. The method can be used in any type of structure but is particularly suitable when it is necessary not to damage the surface of structures. A series of experiments carried out on masonry walls of the Oliverian Museum (Pesaro, Italy) and Palazzo Silvi (Perugia, Italy) have allowed the validation of the procedure elaborated by comparing the results with those derived from traditional measuring techniques.