Woojin Jung

Woojin Jung

Auto-generated profile, based on publicly available information

Woojin Jung

Department of Electrical and Computer Engineering, Seoul National University, Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
JPJuhyung Park
Juhyung Park
WJWoojin Jung
Woojin Jung
ECEun-Jung Choi
Eun-Jung Choi
SOSe-Hong Oh
Se-Hong Oh
JJJinhee Jang
Jinhee Jang
JLJongho Lee
Jongho Lee
In MRI, deep neural networks have been proposed to reconstruct diffusion model parameters. However, the inputs of the networks were designed for a specific diffusion gradient scheme (i.e., diffusion gradient directions and numbers) and a specific b-value that are the same as the training data. In this study, a new deep neural network, referred to as DIFFnet, is developed to function as a generalized reconstruction tool of the diffusion-weighted signals for various gradient schemes and b-values. For generalization, diffusion signals are normalized in a q-space and then projected and quantized, producing a matrix (Qmatrix) as an input for the network. To demonstrate the validity of this approach, DIFFnet is evaluated for diffusion tensor imaging (DIFFnetDTI) and for neurite orientation dispersion and density imaging (DIFFnetNODDI). In each model, two datasets with different gradient schemes and b-values are tested. The results demonstrate accurate reconstruction of the diffusion parameters at substantially reduced processing time (approximately 8.7 times and 2240 times faster processing time than conventional methods in DTI and NODDI, respectively; less than 4% mean normalized root-mean-square errors (NRMSE) in DTI and less than 8% in NODDI). The generalization capability of the networks was further validated using reduced numbers of diffusion signals from the datasets and a public dataset from Human Connection Project. Different from previously proposed deep neural networks, DIFFnet does not require any specific gradient scheme and b-value for its input. As a result, it can be adopted as an online reconstruction tool for various complex diffusion imaging.

30 June 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SJSooyeon Ji
Sooyeon Ji
JJJinhee Jeong
Jinhee Jeong
SOSe-Hong Oh
Se-Hong Oh
YNYoonho Nam
Yoonho Nam
SCSeung Hong Choi
Seung Hong Choi
JLJongho Lee
Jongho Lee
Magnetic resonance imaging (MRI) can provide multiple contrast-weighted images using different pulse sequences and protocols. However, a long acquisition time of the images is a major challenge. To address this limitation, a new pulse sequence referred to as quad-contrast imaging is presented. The quad-contrast sequence enables the simultaneous acquisition of four contrast-weighted images (proton density (PD)-weighted, T 2 -weighted, PD-fluid attenuated inversion recovery (FLAIR), and T 2 -FLAIR), and the synthesis of T 1 -weighted images and T 1 - and T 2 -maps in a single scan. The scan time is less than 6 min and is further reduced to 2 min 50 s using a deep learning-based parallel imaging reconstruction. The natively acquired quad contrasts demonstrate high quality images, comparable to those from the conventional scans. The deep learning-based reconstruction successfully reconstructed highly accelerated data (acceleration factor 6), reporting smaller normalized root mean squared errors (NRMSEs) and higher structural similarities (SSIMs) than those from conventional generalized autocalibrating partially parallel acquisitions (GRAPPA)-reconstruction (mean NRMSE of 4.36% vs. 10.54% and mean SSIM of 0.990 vs. 0.953). In particular, the FLAIR contrast is natively acquired and does not suffer from lesion-like artifacts at the boundary of tissue and cerebrospinal fluid, differentiating the proposed method from synthetic imaging methods. The quad-contrast imaging method may have the potentials to be used in a clinical routine as a rapid diagnostic tool.

24 September 2024 in Neuroradiology
Verified
Journal Article
Open access
PDF file
WJWoojin Jung
Woojin Jung
GJGeunu Jeong
Geunu Jeong
SKSohyun Kim
Sohyun Kim
IHInpyeong Hwang
Inpyeong Hwang
SCSeung Hong Choi
Seung Hong Choi
KKKoung Mi Kang
Koung Mi Kang
Purpose: The time-intensive nature of acquiring 3D T1-weighted MRI and analyzing brain volumetry limits quantitative evaluation of brain atrophy. We explore the feasibility and reliability of deep learning-based accelerated MRI scans for brain volumetry. Methods: This retrospective study collected 3D T1-weighted data using 3T from 42 participants for the simulated acceleration dataset and 48 for the validation dataset. The simulated acceleration dataset consists of three sets at different simulated acceleration levels (Simul-Accel) corresponding to level 1 (65% undersampling), 2 (70%), and 3 (75%). These images were then subjected to deep learning-based reconstruction (Simul-Accel-DL). Conventional images (Conv) without acceleration and DL were set as the reference. In the validation dataset, DICOM images were collected from Conv and accelerated scan with DL-based reconstruction (Accel-DL). The image quality of Simul-Accel-DL was evaluated using quantitative error metrics. Volumetric measurements were evaluated using intraclass correlation coefficients (ICCs) and linear regression analysis in both datasets. The volumes were estimated by two software, NeuroQuant and DeepBrain. Results: Simul-Accel-DL across all acceleration levels revealed comparable or better error metrics than Simul-Accel. In the simulated acceleration dataset, ICCs between Conv and Simul-Accel-DL in all ROIs exceeded 0.90 for volumes and 0.77 for normative percentiles at all acceleration levels. In the validation dataset, ICCs for volumes > 0.96, ICCs for normative percentiles > 0.89, and R2 > 0.93 at all ROIs except pallidum demonstrated good agreement in both software. Conclusion: DL-based reconstruction achieves clinical feasibility of 3D T1 brain volumetric MRI by up to 75% acceleration relative to full-sampled acquisition.