Hussien I. Abdul‐Ghaffar

Hussien I. Abdul‐Ghaffar

Auto-generated profile, based on publicly available information

Hussien I. Abdul‐Ghaffar

New Urban Communities Authority, New Minia City Minia Egypt

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2022 in Neural Networks
Verified
Journal Article
Closed access
GUNASEKARAN NALLAPPANGUNASEKARAN NALLAPPAN
GUNASEKARAN NALLAPPAN
MAMohammed Yacoob Syed Ali
Mohammed Yacoob Syed Ali
Sabri ArikSabri Arik
Sabri Arik
HGH.I. Abdul Ghaffar
H.I. Abdul Ghaffar
AHMED DIABAHMED DIAB
AHMED DIAB

1 November 2021 in Energy Reports
Verified
Journal Article
Open access
AHMED DIABAHMED DIAB
AHMED DIAB
HAHamdi Ali
Hamdi Ali
HAH.I. Abdul-Ghaffar
H.I. Abdul-Ghaffar
Hany A. AbdelsalamHany A. Abdelsalam
Hany A. Abdelsalam
MSMontaser Abd El Sattar
Montaser Abd El Sattar

1 November 2021 in Energy Reports
Verified
Journal Article
Open access
BDBEN HMAMOU DRIS
BEN HMAMOU DRIS
MEMustapha Elyaqouti
Mustapha Elyaqouti
EAElhanafi Arjdal
Elhanafi Arjdal
Ahmed IbrahimAhmed Ibrahim
Ahmed Ibrahim
HAH.I. Abdul-Ghaffar
H.I. Abdul-Ghaffar
AHMED DIABAHMED DIAB
AHMED DIAB

27 October 2023 in IET Renewable Power Generation
Verified
Journal Article
Open access
MAMohamed Abdeen
Mohamed Abdeen
LELoai Mohamed Ali El‐Sayed
Loai Mohamed Ali El‐Sayed
ADAhmed A. Zaki Diab
Ahmed A. Zaki Diab
HAHussien I. Abdul‐Ghaffar
Hussien I. Abdul‐Ghaffar
Detection of sub‐synchronous oscillation (SSO) accurately within a short time poses a big challenge to avoiding the potential risks of the SSO phenomenon. This paper proposes a novel technique for detecting the SSO phenomenon based on identifying the SSO frequency and magnitude rather than applying fast Fourier transform. The voltage magnitude signal is used as an input signal. The SSO magnitude is identified based on estimating the max value of the voltage magnitude signal, whereas the time corresponding to the zero crossings is defined for calculating the SSO frequency. In order to confirm its effectiveness, the proposed technique is tested with different SSO types (induction generator effect, torsional interaction, and sub‐synchronous control interaction). Moreover, the impact of the series compensation level change on the proposed method performance is investigated. The results prove the effectiveness and the speed of the proposed method in all studied cases. Compared to the traditional methods within a wide range of compensation levels, the proposed technique is fast and accurate. The IEEE first benchmark model is adapted with a doubly‐fed induction generator in the MATLAB program to analyze the performance of the proposed method for detecting the SSO phenomenon.