D. S. Patil

D. S. Patil

Auto-generated profile, based on publicly available information

D. S. Patil

Department of Metallurgical Engineering and Materials Science, Semiconductor Thin Film and Plasma Processing Laboratory, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

5 October 2022 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
VGVanya Goel
Vanya Goel
RKRajib Kar
Rajib Kar
ARAmitava Roy
Amitava Roy
DPD. S. Patil
D. S. Patil
NMNamita Maiti
Namita Maiti
In this article, the optimization of spatial parameters of a 2.45-GHz atmospheric pressure plasma jet (APPJ) at different operational parameters has been done. For this purpose, simulations and experiments have been carried out to investigate the spatial dimensions of the microwave cold plasma jet generated from the device. To achieve this, the plasma discharge behavior and jet formation have been studied at different working gas flow rates and input microwave power. The 3-D simulations have been carried out by using the plasma module and electromagnetic wave module of COMSOL Multiphysics v. 5.5. Experimental validation was achieved and simulated spatial dimensions of plasma jet showed good correspondence with the experimental results. Simulated variations of jet length and diameter with gas flow rate and applied power matched closely with experimental results. Intrinsic plasma parameters, such as electron temperature ( $T_{e})$ and number density ( $n_{e})$ , were also obtained with the simulation model and compared with experimental findings based on optical emission spectroscopy (OES) results and $T_{e}$ values matched well in both cases.

15 September 2020 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
PKPartha Karar
Partha Karar
GKGourav Kumar
Gourav Kumar
RKRajib Kar
Rajib Kar
HKHitesh M. Kewlani
Hitesh M. Kewlani
DPD. S. Patil
D. S. Patil
RDRajiv O. Dusane
Rajiv O. Dusane
Langmuir probe (LP) diagnostics is performed on an inductively coupled plasma (ICP) generated using a flat spiral antenna. The current-voltage (I-V) characteristics are measured using a radio frequency (RF) compensated LP to mitigate the effect of RF distortion in I-V measurements. All-important plasma parameters such as electron density (ne), electron temperature (T e ), plasma potential (V p ), and electron energy distribution function (EEDF) are measured in a cylindrical-shaped ICP. The plasma is generated by feeding RF (13.56 MHz) current in the planer multiple spiral antennas. It is seen that the plasma is uniform over an area with 200 mm diameter, with an electron number density in the range from~10 11 to 10 12 cm -3 . Typically for plasma processing of materials, the required density fall in that region. Variation of plasma parameters is investigated as a function of applied RF power and operating pressure and the observed results are discussed.

1 September 2014 in Applied Surface Science
Verified
Journal Article
Closed access
SCS.S. Chopade
S.S. Chopade
CNC. Nayak
C. Nayak
DBD. Bhattacharyya
D. Bhattacharyya
SJS.N. Jha
S.N. Jha
RTR.B. Tokas
R.B. Tokas
DPD.S. Patil
D.S. Patil

21 November 2023 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
PKPartha Karar
Partha Karar
GKGourav Kumar
Gourav Kumar
RKRajib Kar
Rajib Kar
DPD. S. Patil
D. S. Patil
RDRajiv O. Dusane
Rajiv O. Dusane
Diagnostics of the inductively coupled plasma (ICP) generated using a flat spiral antenna are performed using radio frequency (RF) compensated Langmuir probe (CLP). The measurements on the generated plasma are made under the varying influence of the RF self-biased substrate electrode immersed in the plasma. From the $V$ – $I$ characteristics of the Langmuir probe taken at different radial locations in the plasma volume at a fixed axial distance of 5 cm from the quartz isolation window, electron energy probability functions (EEPFs) at various locations are obtained. It is observed that there is a strong correlation between the plasma parameters and EEPF with the bias on the substrate electrode. At a constant RF power in antenna coils, the EEPF evolved from bi-Maxwellian to Maxwellian with an increase in the bias level on the substrate electrode. The evolution of the EEPF with a variation of operating pressure is explained in terms of different heating mechanisms in plasma. Furthermore, EEPF evolution in the plasma from Maxwellian to bi-Maxwellian under the varying influence of RF power fed to the antenna coils keeping RF self-bias level on the substrate electrode constant is also explained.

3 August 2020 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
PKPartha Karar
Partha Karar
GKGourav Kumar
Gourav Kumar
NWNilesh Wadibhasme
Nilesh Wadibhasme
DPD. S. Patil
D. S. Patil
RDRajiv O. Dusane
Rajiv O. Dusane
Amorphous silicon (a-Si:H) thin films are deposited on silicon substrates by inductively coupled plasma chemical vapor deposition (ICP-CVD) using a flat spiral antenna and SiH₄ as the precursor gas. The films are deposited at operating pressure of 20 mTorr and 50-W radio frequency (13.56 MHz) power fed to the antenna. Films are deposited by varying the distance (dₛ) between the dielectric (quartz) plate that isolates the flat spiral antenna from the chamber and the substrate location. Diagnostics of the Argon plasma generated under similar experimental conditions are performed using RF compensated Langmuir probe to get an idea about the variation in plasma parameters (plasma density, electron temperature, and plasma potential) along the axial direction (with the increase in dₛ). The deposited films are characterized for their thickness and various physical and electronic properties. It is observed that there exists a discernible dependence of the film characteristics and the coil to substrate distance (dₛ). It is also found that there is a correlation between the microstructural parameters and the optoelectronic properties as well as the electronic defect density in the films with the coil to substrate distance. An attempt has been made to correlate these observations to the plasma parameters studied by the Langmuir probe.