Rajdip Debnath

Rajdip Debnath

Auto-generated profile, based on publicly available information

Rajdip Debnath

EEE Department, BIT Mesra, Ranchi, India

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2024 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
RDRajdip Debnath
Rajdip Debnath
DKDeepak Kumar
Deepak Kumar
GGGauri Shanker Gupta
Gauri Shanker Gupta
SSSubhransu Ranjan Samantaray
Subhransu Ranjan Samantaray
Ehab El-SaadanyEhab El-Saadany
Ehab El-Saadany
The pursuit of seamless formation and robust control of inverters in power electronic-dominated grids face challenges arising from uncertainties in grid impedance, dynamic load variations, and transitional phase jump scenarios, leading to elevated instability during mode transitions. These challenges necessitate a nuanced approach to voltage regulation and stability analysis to manage the stochastic nonlinearities and inherent dynamics effectively. This paper introduces a novel Unified Koopman-based Model Predictive Control (K-MPC) method that synergizes a modified MPC framework with an ensemble approach and a saturation-like automatic adaptation function for seamless inverter transitions. It facilitates precise power-sharing among inverters in isolated microgrids by adjusting output impedances without the need for communication lines, thereby addressing the limitations in dynamic response, sensor requirements, filter fluctuations, and controller complexity. The K-MPC method enhances system performance and fidelity by incorporating online adaptation norms for external disturbance rejection, aligning closely with a predefined reference model. Quantitative validation, conducted through frequency response analysis and hardware-in-the-loop (HIL) experiments on an IEEE 123-node test system, underscores the method’s effectiveness. The K-MPC approach notably reduces total harmonic distortion (THD) by up to 30% relative to conventional control strategies and improves power-sharing precision among inverters by 25% under dynamic loading conditions. Furthermore, it exhibits a 40% faster response in adapting to external disturbances, ensuring voltage and frequency remain within target thresholds.

16 September 2025 in IEEE Access
Verified
Journal Article
Open access
RDRajdip Debnath
Rajdip Debnath
AUAbdullah Umar
Abdullah Umar
GGGauri Shanker Gupta
Gauri Shanker Gupta
DKDeepak Kumar
Deepak Kumar
Innocent KamwaInnocent Kamwa
Innocent Kamwa
PJPrashant Kumar Jamwal
Prashant Kumar Jamwal
The integration of renewable energy sources and distributed energy resources (DERs) has driven the evolution of modernized nested microgrids, enhancing resilience and flexibility in power distribution systems. Grid-following (GFL) and grid-forming (GFM) inverters are central to these systems, with GFL units emulating current sources challenged by uncertain grid impedance, and GFM units emulating voltage sources required to adapt to dynamic load variations. Mode transitions introduce instability through multi-loop control interactions. This work presents a comprehensive dynamical stability analysis of GFL and GFM inverters in nested microgrids, supported by advanced control strategies addressing dynamic response limitations, sensor dependencies, filter fluctuations, and controller complexities. An eigenvalue-based framework identifies dominant oscillatory modes, while online adaptation mitigates disturbances to preserve closed-loop performance. Time-evolution modeling of observables enables enhanced real-time monitoring. A blockchain-enabled decentralized framework ensures secure, transparent, and automated stability actions. Hardware-in-the-loop (HIL) experiments on a modified IEEE 123-node test feeder demonstrate a total harmonic distortion (THD) of 1.75% under weak-grid conditions compared with 2.73%, 4.76%, 8.40%, and 2.2% for other approaches and 0.3% under grid-impedance variation and <0.3% under nonlinear loading. The proposed controller achieves 0.06% tracking error dynamics and 0.02% steady-state error, outperforming classical methods (0.32–0.87% and 0.17–0.38%, respectively), with a computational time of 29 ms. The blockchain layer, implemented on the Polygon network, achieved a measured throughput of 1,572 transactions/s, an average block time of 2.3 s, and transaction fees below 0.01 USD, enabling rapid, economical, and scalable peer-to-peer stability service execution.

6 October 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
RDRajdip Debnath
Rajdip Debnath
GGGauri Shanker Gupta
Gauri Shanker Gupta
DKDeepak Kumar
Deepak Kumar
SSSubrat Kumar Swain
Subrat Kumar Swain
SSSubhransu Ranjan Samantaray
Subhransu Ranjan Samantaray
Innocent KamwaInnocent Kamwa
Innocent Kamwa
This research article presents an innovative approach to enhance the performance and robustness of voltage source converters within microgrid systems. Existing controls suffer from slow convergence and unsatisfactory transient performance when dealing with disturbances, especially in the presence of control delay. To discourse these limitations, the proposed sliding mode controller is augmented with a nonlinear disturbance observer to enhance the disturbance elimination capability, attenuates the effect of parameter uncertainties, superior voltage reference tracking and suppressing chattering in the control response. The observer is introduced to estimate sensor values, potentially eliminating the need for dedicated sensors. The proposed control strategy employs a switching Lyapunov function-based mathematical model, addressing dynamic response limitations and switching action incorporating nonlinearities in the proposed model. By incorporating Lyapunov-based stability analysis, the article overcomes limitations and conservatisms associated with traditional linearized techniques, enabling more accurate stability assessments. Online adaptation norms are integrated to estimate and reject external disturbances, aligning closed-loop responses with reference models. Extensive numerical simulations and hardware-in-the-loop experiments validate the improved performance, highlighting the elimination of chattering and enhanced robustness against step and stochastic disturbances.