C. Lowekamp Bradley

C. Lowekamp Bradley

Auto-generated profile, based on publicly available information

C. Lowekamp Bradley

Bioinformatics and Computational Bioscience Branch, NIAID, NIH

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2020 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
ARAndrea J. Radtke
Andrea J. Radtke
EKEvelyn Kandov
Evelyn Kandov
BLBradley Lowekamp
Bradley Lowekamp
ESEmily Speranza
Emily Speranza
CCColin J. Chu
Colin J. Chu
RGRonald N. Germain
Ronald N. Germain
Significance: Single-cell flow cytometry and genomic methods are rapidly increasing our knowledge of the diversity of cell types in metazoan tissues. However, suitably robust methods for placing these cells in a spatial context that reveals how their localization and putative interactions contribute to tissue physiology and pathology are still lacking. Here we provide a readily accessible pipeline (IBEX) for highly multiplex immunofluorescent imaging that enables a fine-grained analysis of cells in their tissue context. Additionally, we describe extensions of the IBEX workflow to handle hard-to-image tissue preparations and a method to facilitate direct integration of the imaging data with flow cytometry and sequencing technologies.

5 June 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
ARAndrea J. Radtke
Andrea J. Radtke
EPEkaterina Postovalova
Ekaterina Postovalova
AVArina Varlamova
Arina Varlamova
ABAlexander Bagaev
Alexander Bagaev
MSMaria Sorokina
Maria Sorokina
RGRonald N. Germain
Ronald N. Germain
SUMMARY: Reference atlases, molecular and spatial maps of mammalian tissues, are critical resources for discovery efforts and translational research. Their utility is dependent on operationalizing the resulting data by identifying cell types, histological patterns, and predictive biomarkers underlying health and disease. The human lymph node (LN) offers a compelling use case because of its importance in immunity, structural and cellular diversity, and neoplastic involvement. One hematological malignancy, follicular lymphoma (FL), evolves from developmentally blocked germinal center B cells residing in and trafficking through these tissues. To promote survival and immune escape, tumor B cells undergo significant genetic changes and extensively remodel the lymphoid microenvironment. Here, we present an integrated portrait of healthy and FL LNs using multiple genomic and advanced imaging technologies. By leveraging the strengths of each platform, we identified several tumor-specific features and microenvironmental patterns enriched in individuals who experience early relapse, the most high-risk of FL patients.

23 March 2021
Verified
Dataset
Open access
JAJ. Radtke Andrea
J. Radtke Andrea
JCJ. Chu Colin
J. Chu Colin
YZYaniv Ziv
Yaniv Ziv
YLYao Li
Yao Li
MJMarr James
Marr James
NRN. Germain Ronald
N. Germain Ronald
These datasets were acquired using the Iterative Bleaching Extends multi-pleXity (IBEX) imaging method described in: “IBEX: A versatile multi-plex optical imaging approach for deep phenotyping and spatial analysis of cells in complex tissues“, A. Radtke et al., 2020, doi.org/10.1073/pnas.2018488117. “IBEX: An open and extensible method for high content multiplex imaging of diverse tissues”, A. Radtke et al., 2021, arXiv:2107.11364. Acquisition of 3D data utilized the manual protocol while acquisition of the 2D data utilized the automated protocol. All data is stored using the Imaris file format. To view these multi-channel images, you can either use one of these free viewers, Imaris viewer (Oxford Instruments), Fiji. Images can be registered using the code available on GitHub (XTRegisterSameChannel: “Affine registration of z-stacks using common channel”). A video illustrating the usage of the Imaris extension to register this data is available on YouTube. Human Spleen Dataset is comprised of a four-cycle manual IBEX experiment performed on human spleen sections labeled with the nuclear marker Hoechst and antibodies directed against the indicated markers. Images were acquired using an inverted Leica TCS SP8 X confocal microscope equipped with a 40X objective (NA 1.3), 4 HyD and 1 PMT detectors, a white light laser that produces a continuous spectral output between 470 and 670 nm as well as 405, 685, and 730 nm lasers. All images were captured at an 8-bit depth, with a line average of 3, and 1024x1024 format with the following pixel dimensions: x (0.284 um), y (0.284 um), and z (1 um). Images were tiled and merged using the LAS X Navigator software (LAS X 3.5.5.19976). Markers per channel in each of the cycles: Human_Spleen_Panel1.ims (7 channels): CD21, CD54, Hoechst, CD20, CD68, Glycophorin A, Fibrinogen Human_Spleen_Panel2.ims (7 channels): CD163, CD49a, CD138, Hoechst, CD15, HLA-DR, CD11c Human_Spleen_Panel3.ims (7 channels): Vimentin, CD4, CD31, Ki-67, Hoechst, CD3, CD8 Human_Spleen_Panel4.ims (7 channels): SPARC, CD44, Hoechst, CD61, CD45, SMA, Lumican Registration - If using our Imaris Extensions registration code, this dataset uses the default settings. Human Liver Dataset is comprised of a four-cycle manual IBEX experiment performed on human liver sections labeled with the nuclear marker Hoechst and antibodies directed against the indicated markers. Images were acquired using an inverted Leica TCS SP8 X confocal microscope equipped with a 40X objective (NA 1.3), 4 HyD and 1 PMT detectors, a white light laser that produces a continuous spectral output between 470 and 670 nm as well as 405, 685, and 730 nm lasers. All images were captured at an 8-bit depth, with a line average of 3, and 1024x1024 format with the following pixel dimensions: x (0.284 um), y (0.284 um), and z (1 um). Images were tiled and merged using the LAS X Navigator software (LAS X 3.5.5.19976). Markers per channel in each of the cycles: Human_Liver_Panel1.ims (6 channels): CD54, ASS1, Lyve-1, Hoechst, Keratin 7, CD34 Human_Liver_Panel2.ims (6 channels): CD163, CD138, Fibrinogen, Hoechst, HLA-DR, CD68 Human_Liver_Panel3.ims (7 channels): CD4, Glutamine Synthetase, Ki-67, Hoechst, CD3, CD8, Tubulin beta 3 Human_Liver_Panel4.ims (6 channels): CD44, Vimentin, CD49a, Hoechst, SMA, CD45 Registration - If using our Imaris Extensions registration code, this dataset requires that you modify the default settings. Using the advanced settings dialog you need to: Disable the FFT option. Enable the 2D affine option. Human Kidney Dataset is comprised of a four-cycle automated IBEX experiment performed on human kidney Formalin-Fixed Paraffin-Embedded (FFPE) sections labeled with the nuclear marker Hoechst and antibodies directed against the indicated markers. Images were acquired using an inverted Thunder 3D Cell Culture microscope with a high precision (Quantum) stage, a high quantum efficiency sCMOS camera (DFC9000 GTC), and a 40x (1.3) NA oil objective. The light source was an LED8 with 8 individual LED lines for excitation with millisecond triggering. All images were captured at a 16-bit depth with the following pixel dimensions: x (0.160 um), y (0.160 um), and z (1 um). Images were tiled and merged using the LAS X Navigator software (LAS X 3.7.1.21655). Markers per channel in each of the cycles: Human_Kidney_Panel1.ims (4 channels): Hoechst, Cytokeratin, CD34, SMA Human_Kidney_Panel2.ims (3 channels): Hoechst, CD10, Cathepsin L Human_Kidney_Panel3.ims (3 channels): Hoechst, CD15, TMPRSS2 Human_Kidney_Panel4.ims (3 channels): Hoechst, Vimentin, Glycophorin A Registration - If using our Imaris Extensions registration code, this dataset uses the default settings.

23 March 2021
Verified
Dataset
Open access
JAJ. Radtke Andrea
J. Radtke Andrea
JCJ. Chu Colin
J. Chu Colin
YZYaniv Ziv
Yaniv Ziv
YLYao Li
Yao Li
MJMarr James
Marr James
NRN. Germain Ronald
N. Germain Ronald
These datasets were acquired using the Iterative Bleaching Extends multi-pleXity (IBEX) imaging method described in: “IBEX: A versatile multi-plex optical imaging approach for deep phenotyping and spatial analysis of cells in complex tissues“, A. Radtke et al., 2020, doi.org/10.1073/pnas.2018488117. “IBEX: An open and extensible method for high content multiplex imaging of diverse tissues”, A. Radtke et al., 2021, arXiv:2107.11364. Acquisition of 3D data utilized the manual protocol while acquisition of the 2D data utilized the automated protocol. All data is stored using the Imaris file format. To view these multi-channel images, you can either use one of these free viewers, Imaris viewer (Oxford Instruments), Fiji. Images can be registered using the code available on GitHub (XTRegisterSameChannel: “Affine registration of z-stacks using common channel”). A video illustrating the usage of the Imaris extension to register this data is available on YouTube. Human Spleen Dataset is comprised of a four-cycle manual IBEX experiment performed on human spleen sections labeled with the nuclear marker Hoechst and antibodies directed against the indicated markers. Images were acquired using an inverted Leica TCS SP8 X confocal microscope equipped with a 40X objective (NA 1.3), 4 HyD and 1 PMT detectors, a white light laser that produces a continuous spectral output between 470 and 670 nm as well as 405, 685, and 730 nm lasers. All images were captured at an 8-bit depth, with a line average of 3, and 1024x1024 format with the following pixel dimensions: x (0.284 um), y (0.284 um), and z (1 um). Images were tiled and merged using the LAS X Navigator software (LAS X 3.5.5.19976). Markers per channel in each of the cycles: Human_Spleen_Panel1.ims (7 channels): CD21, CD54, Hoechst, CD20, CD68, Glycophorin A, Fibrinogen Human_Spleen_Panel2.ims (7 channels): CD163, CD49a, CD138, Hoechst, CD15, HLA-DR, CD11c Human_Spleen_Panel3.ims (7 channels): Vimentin, CD4, CD31, Ki-67, Hoechst, CD3, CD8 Human_Spleen_Panel4.ims (7 channels): SPARC, CD44, Hoechst, CD61, CD45, SMA, Lumican Registration - If using our Imaris Extensions registration code, this dataset uses the default settings. Human Liver Dataset is comprised of a four-cycle manual IBEX experiment performed on human liver sections labeled with the nuclear marker Hoechst and antibodies directed against the indicated markers. Images were acquired using an inverted Leica TCS SP8 X confocal microscope equipped with a 40X objective (NA 1.3), 4 HyD and 1 PMT detectors, a white light laser that produces a continuous spectral output between 470 and 670 nm as well as 405, 685, and 730 nm lasers. All images were captured at an 8-bit depth, with a line average of 3, and 1024x1024 format with the following pixel dimensions: x (0.284 um), y (0.284 um), and z (1 um). Images were tiled and merged using the LAS X Navigator software (LAS X 3.5.5.19976). Markers per channel in each of the cycles: Human_Liver_Panel1.ims (6 channels): CD54, ASS1, Lyve-1, Hoechst, Keratin 7, CD34 Human_Liver_Panel2.ims (6 channels): CD163, CD138, Fibrinogen, Hoechst, HLA-DR, CD68 Human_Liver_Panel3.ims (7 channels): CD4, Glutamine Synthetase, Ki-67, Hoechst, CD3, CD8, Tubulin beta 3 Human_Liver_Panel4.ims (6 channels): CD44, Vimentin, CD49a, Hoechst, SMA, CD45 Registration - If using our Imaris Extensions registration code, this dataset requires that you modify the default settings. Using the advanced settings dialog you need to: Disable the FFT option. Enable the 2D affine option. Human Kidney Dataset is comprised of a four-cycle automated IBEX experiment performed on human kidney Formalin-Fixed Paraffin-Embedded (FFPE) sections labeled with the nuclear marker Hoechst and antibodies directed against the indicated markers. Images were acquired using an inverted Thunder 3D Cell Culture microscope with a high precision (Quantum) stage, a high quantum efficiency sCMOS camera (DFC9000 GTC), and a 40x (1.3) NA oil objective. The light source was an LED8 with 8 individual LED lines for excitation with millisecond triggering. All images were captured at a 16-bit depth with the following pixel dimensions: x (0.160 um), y (0.160 um), and z (1 um). Images were tiled and merged using the LAS X Navigator software (LAS X 3.7.1.21655). Markers per channel in each of the cycles: Human_Kidney_Panel1.ims (4 channels): Hoechst, Cytokeratin, CD34, SMA Human_Kidney_Panel2.ims (3 channels): Hoechst, CD10, Cathepsin L Human_Kidney_Panel3.ims (3 channels): Hoechst, CD15, TMPRSS2 Human_Kidney_Panel4.ims (3 channels): Hoechst, Vimentin, Glycophorin A Registration - If using our Imaris Extensions registration code, this dataset uses the default settings.

31 July 2009 in The Insight Journal
Verified
Journal Article
Open access
BLBradley Lowekamp
Bradley Lowekamp
DCDavid Chen
David Chen