Hester van der Vaart

Hester van der Vaart

Auto-generated profile, based on publicly available information

Hester van der Vaart

Department of Pulmonary Diseases, University Medical Center Groningen, University of Groningen, Groningen, Netherlands

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
MOMartinus C Oppelaar
Martinus C Oppelaar
YEYvette Emond
Yvette Emond
MBMichiel A.G.E. Bannier
Michiel A.G.E. Bannier
MRMonique Reijers
Monique Reijers
HVHester van der Vaart
Hester van der Vaart
JRJ Roukema
J Roukema
Background: The current literature inadequately addresses the extent to which remote monitoring should be integrated into care models for chronic respiratory diseases (CRDs). Objective: This study examined a remote monitoring program (RMP) in cystic fibrosis (CF) by exploring experiences, future perspectives, and use behavior over 3 years, with the aim of developing future directions for remote monitoring in CRDs. Methods: This was a mixed methods, multicenter, observational study in 5 Dutch CF centers following a sequential explanatory design. Self-designed questionnaires using the technology acceptance model were sent out to people with CF who had a minimum of 12 months of experience with the RMP and local health care professionals (HCPs). Questionnaire outcomes were used to inform semistructured interviews with HCPs and people with CF. Qualitative findings were reported following the COREQ (Consolidated Criteria for Reporting Qualitative Research) checklist. Anonymous data on use frequency of all people with CF were analyzed. Results: Between the second quarter of 2020 and the end of 2022, a total of 608 people with CF were enrolled in the program, and a total of 9418 lung function tests and 2631 symptom surveys were conducted. In total, 65% (24/37) of HCPs and 89% (72/81) of people with CF responded to the questionnaire, and 7 HCPs and 12 people with CF participated in semistructured interviews. Both people with CF and HCPs were positive about remote monitoring in CF care and found the RMP a good addition to daily care (people with CF: 44/72, 61%; HCPs: 21/24, 88%). Benefits ranged from supporting individual patients to reducing health care consumption. The most valued monitoring tool was home spirometry by both people with CF (66/72, 92%) and HCPs (22/24, 92%). Downsides included the potential to lose sight of patients and negative psychosocial effects, as 17% (12/72) of people with CF experienced some form of stress due to the RMP. A large majority of people with CF (59/72, 82%) and HCPs (22/24, 92%) wanted to keep using the RMP in future, with 79% (19/24) of HCPs and 75% (54/72) of people with CF looking forward to more replacement of in-person care with digital care during periods of well-being. Future perspectives for the RMP were centered on creating hybrid care models, personalizing remote care, and balancing individual benefits with monitoring burden. Conclusions: Remote monitoring has considerable potential in supporting people with CF and HCPs within the CF care model. We identified 4 practice-based future directions for remote monitoring in CF and CRD care. The strategies, ranging from patient driven to prediction driven, can help clinicians, researchers, and policy makers navigate the rapidly changing digital health field, integrate remote monitoring into local care models, and align remote care with patient and clinician needs.

3 December 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
MOMartinus C Oppelaar
Martinus C Oppelaar
HHHanneke Ac van Helvoort
Hanneke Ac van Helvoort
MBMichiel A.G.E. Bannier
Michiel A.G.E. Bannier
MRMonique Reijers
Monique Reijers
HVHester van der Vaart
Hester van der Vaart
JRJ Roukema
J Roukema
Background: Portable spirometers are increasingly used to measure lung function at home, but doubts about the accuracy of these devices persist. These doubts stand in the way of the digital transition of chronic respiratory disease care, hence there is a need to address the accuracy of home spirometry in routine care across multiple settings and ages. Objective: This study aimed to assess the accuracy, reproducibility, and responsiveness to the treatment of home spirometry in long-term pediatric and adult cystic fibrosis care. Methods: This retrospective observational study was carried out in 5 Dutch cystic fibrosis centers. Home spirometry outcomes (forced expiratory volume in one second [FEV1], and forced vital capacity [FVC]) for 601 anonymized users were collected during 3 years. For 81 users, data on clinic spirometry and elexacaftor/tezacaftor/ivacaftor (ETI) use were available. Accuracy was assessed using Bland-Altman plots for paired clinic-home measurements on the same day and within 7 days of each other (nearest neighbor). Intratest reproducibility was assessed using the American Thoracic Society/European Respiratory Society repeatability criteria, the coefficient of variation, and spirometry quality grades. Responsiveness was measured by the percentage change in home spirometry outcomes after the start of ETI. Results: Bland-Altman analysis was performed for 86 same-day clinic-home spirometry pairs and for 263 nearest neighbor clinic-home spirometry pairs (n=81). For both sets and for both FEV1 and FVC, no heteroscedasticity was present and hence the mean bias was expressed as an absolute value. Overall, home spirometry was significantly lower than clinic spirometry (mean ΔFEV1clinic-home 0.13 L, 95% CI 0.10 to 0.19; mean ΔFVCclinic-home 0.20 L, 95% CI 0.14 to 0.25) and remained lower than clinic spirometry independent of age and experience. One-way ANOVA with post hoc comparisons showed significantly lower differences in clinic-home spirometry in adults than in children (Δmean 0.11, 95% CI –0.20 to –0.01) and teenagers (Δmean 0.14, 95% CI –0.25 to –0.02). For reproducibility analyses, 2669 unique measurement days of 311 individuals were included. Overall, 87.3% (2331/2669) of FEV1 measurements and 74.3% (1985/2669) of FVC measurements met reproducibility criteria. Kruskal-Wallis with pairwise comparison demonstrated that for both FVC and FEV1, coefficient of variation was significantly lower in adults than in children and teenagers. A total of 5104 unique home measurements were graded. Grade E was given to 2435 tests as only one home measurement was performed. Of the remaining 2669 tests, 43.8% (1168/2669) and 43.6% (1163/2669) received grade A and B, respectively. The median percentage change in FEV1 from baseline after initiation of ETI was 19.2% after 7-14 days and remained stable thereafter (n=33). Conclusions: Home spirometry is feasible but not equal to clinic spirometry. Home spirometry can confirm whether lung functions remain stable, but the context of measurement and personal trends are more relevant than absolute outcomes.

9 January 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
PBPia Bertram
Pia Bertram
MOMartinus C Oppelaar
Martinus C Oppelaar
MBMichiel A.G.E. Bannier
Michiel A.G.E. Bannier
MRMonique Reijers
Monique Reijers
HVHester van der Vaart
Hester van der Vaart
JRJ Roukema
J Roukema
Background: Home spirometers have been widely implemented in the treatment of people with cystic fibrosis (CF). Frequent spirometry measurements at home could lead to earlier detection of exacerbations. However, previous research indicates that the long-term use of home spirometry is not well maintained by people with CF. Objective: We aimed to gain insight into the long-term uptake of home spirometry in regular multicenter CF care. Methods: Home spirometers combined with a remote monitoring platform were introduced in the treatment of people with CF in 5 Dutch CF centers starting in April 2020. Usage data from April 2020 to December 2022 were analyzed retrospectively. Survival analyses were conducted to assess use consistency over time, and t tests were used to evaluate the impact of increased pulmonary symptoms on home spirometry frequency. The effect of the initiation of a new treatment, Elexacaftor/Tezacaftor/Ivacaftor, on use frequency over time was assessed in a subgroup of participants with repeated measures ANOVA. Results: During the observation period, a total of 604 people with CF were enrolled in the remote monitoring platform and 9930 home spirometry measurements were performed. After the initiation of home spirometry use, the number of users declined rapidly. One year after the initiation, 232 (54.2%) people with CF stopped using home spirometry. During the observation period, 67 (11.1%) users performed more than 20 measurements. Furthermore, the number of consistent home spirometry users decreased over time. After 600 days, only 1% of users had measured their lung function consistently every 31 days. Use frequency slightly increased during periods with increased pulmonary symptoms (ΔMean=0.45, t497.278=–4,197; P<.001) and showed an initial rise followed by a decrease after starting treatment with Elexacaftor/Tezacaftor/Ivacaftor (ΔMean=0.45, t497.278=–4,197; P<.001). Conclusions: Consistent uptake of home spirometry in people with CF is low but increases around periods of changing symptoms. A clear strategy for the organization of remote care seemed to improve the long-term uptake of home spirometry. Nevertheless, home spirometry and its intensity are not a goal on their own but should be used as a tool to reach individual goals within local contexts.

28 November 2023 in JMIR Preprints
Verified
Preprint
Open access
MOMartinus C Oppelaar
Martinus C Oppelaar
YEYvette Emond
Yvette Emond
MBMichiel A.G.E. Bannier
Michiel A.G.E. Bannier
MRMonique Reijers
Monique Reijers
HVHester van der Vaart
Hester van der Vaart
JRJ Roukema
J Roukema
BACKGROUND The current literature inadequately addresses the extent to which remote monitoring should be integrated into care models for chronic respiratory diseases (CRDs). OBJECTIVE This study examined a remote monitoring program (RMP) in cystic fibrosis (CF) by exploring experiences, future perspectives, and use behavior over 3 years, with the aim of developing future directions for remote monitoring in CRDs. METHODS This was a mixed methods, multicenter, observational study in 5 Dutch CF centers following a sequential explanatory design. Self-designed questionnaires using the technology acceptance model were sent out to people with CF who had a minimum of 12 months of experience with the RMP and local health care professionals (HCPs). Questionnaire outcomes were used to inform semistructured interviews with HCPs and people with CF. Qualitative findings were reported following the COREQ (Consolidated Criteria for Reporting Qualitative Research) checklist. Anonymous data on use frequency of all people with CF were analyzed. RESULTS Between the second quarter of 2020 and the end of 2022, a total of 608 people with CF were enrolled in the program, and a total of 9418 lung function tests and 2631 symptom surveys were conducted. In total, 65% (24/37) of HCPs and 89% (72/81) of people with CF responded to the questionnaire, and 7 HCPs and 12 people with CF participated in semistructured interviews. Both people with CF and HCPs were positive about remote monitoring in CF care and found the RMP a good addition to daily care (people with CF: 44/72, 61%; HCPs: 21/24, 88%). Benefits ranged from supporting individual patients to reducing health care consumption. The most valued monitoring tool was home spirometry by both people with CF (66/72, 92%) and HCPs (22/24, 92%). Downsides included the potential to lose sight of patients and negative psychosocial effects, as 17% (12/72) of people with CF experienced some form of stress due to the RMP. A large majority of people with CF (59/72, 82%) and HCPs (22/24, 92%) wanted to keep using the RMP in future, with 79% (19/24) of HCPs and 75% (54/72) of people with CF looking forward to more replacement of in-person care with digital care during periods of well-being. Future perspectives for the RMP were centered on creating hybrid care models, personalizing remote care, and balancing individual benefits with monitoring burden. CONCLUSIONS Remote monitoring has considerable potential in supporting people with CF and HCPs within the CF care model. We identified 4 practice-based future directions for remote monitoring in CF and CRD care. The strategies, ranging from patient driven to prediction driven, can help clinicians, researchers, and policy makers navigate the rapidly changing digital health field, integrate remote monitoring into local care models, and align remote care with patient and clinician needs.

24 May 2024 in JMIR Preprints
Verified
Preprint
Open access
MOMartinus C Oppelaar
Martinus C Oppelaar
HHHanneke Ac van Helvoort
Hanneke Ac van Helvoort
MBMichiel A.G.E. Bannier
Michiel A.G.E. Bannier
MRMonique Reijers
Monique Reijers
HVHester van der Vaart
Hester van der Vaart
JRJ Roukema
J Roukema
BACKGROUND Portable spirometers are increasingly used to measure lung function at home, but doubts about the accuracy of these devices persist. These doubts stand in the way of the digital transition of chronic respiratory disease care, hence there is a need to address the accuracy of home spirometry in routine care across multiple settings and ages. OBJECTIVE This study aimed to assess the accuracy, reproducibility, and responsiveness to the treatment of home spirometry in long-term pediatric and adult cystic fibrosis care. METHODS This retrospective observational study was carried out in 5 Dutch cystic fibrosis centers. Home spirometry outcomes (forced expiratory volume in one second [FEV1], and forced vital capacity [FVC]) for 601 anonymized users were collected during 3 years. For 81 users, data on clinic spirometry and elexacaftor/tezacaftor/ivacaftor (ETI) use were available. Accuracy was assessed using Bland-Altman plots for paired clinic-home measurements on the same day and within 7 days of each other (nearest neighbor). Intratest reproducibility was assessed using the American Thoracic Society/European Respiratory Society repeatability criteria, the coefficient of variation, and spirometry quality grades. Responsiveness was measured by the percentage change in home spirometry outcomes after the start of ETI. RESULTS Bland-Altman analysis was performed for 86 same-day clinic-home spirometry pairs and for 263 nearest neighbor clinic-home spirometry pairs (n=81). For both sets and for both FEV1 and FVC, no heteroscedasticity was present and hence the mean bias was expressed as an absolute value. Overall, home spirometry was significantly lower than clinic spirometry (mean ΔFEV1clinic-home 0.13 L, 95% CI 0.10 to 0.19; mean ΔFVCclinic-home 0.20 L, 95% CI 0.14 to 0.25) and remained lower than clinic spirometry independent of age and experience. One-way ANOVA with post hoc comparisons showed significantly lower differences in clinic-home spirometry in adults than in children (Δmean 0.11, 95% CI –0.20 to –0.01) and teenagers (Δmean 0.14, 95% CI –0.25 to –0.02). For reproducibility analyses, 2669 unique measurement days of 311 individuals were included. Overall, 87.3% (2331/2669) of FEV1 measurements and 74.3% (1985/2669) of FVC measurements met reproducibility criteria. Kruskal-Wallis with pairwise comparison demonstrated that for both FVC and FEV1, coefficient of variation was significantly lower in adults than in children and teenagers. A total of 5104 unique home measurements were graded. Grade E was given to 2435 tests as only one home measurement was performed. Of the remaining 2669 tests, 43.8% (1168/2669) and 43.6% (1163/2669) received grade A and B, respectively. The median percentage change in FEV1 from baseline after initiation of ETI was 19.2% after 7-14 days and remained stable thereafter (n=33). CONCLUSIONS Home spirometry is feasible but not equal to clinic spirometry. Home spirometry can confirm whether lung functions remain stable, but the context of measurement and personal trends are more relevant than absolute outcomes.

19 May 2024 in JMIR Preprints
Verified
Preprint
Open access
PBPia Bertram
Pia Bertram
MOMartinus C Oppelaar
Martinus C Oppelaar
MBMichiel A.G.E. Bannier
Michiel A.G.E. Bannier
MRMonique Reijers
Monique Reijers
HVHester van der Vaart
Hester van der Vaart
JRJ Roukema
J Roukema
BACKGROUND Home spirometers have been widely implemented in the treatment of people with cystic fibrosis (CF). Frequent spirometry measurements at home could lead to earlier detection of exacerbations. However, previous research indicates that the long-term use of home spirometry is not well maintained by people with CF. OBJECTIVE We aimed to gain insight into the long-term uptake of home spirometry in regular multicenter CF care. METHODS Home spirometers combined with a remote monitoring platform were introduced in the treatment of people with CF in 5 Dutch CF centers starting in April 2020. Usage data from April 2020 to December 2022 were analyzed retrospectively. Survival analyses were conducted to assess use consistency over time, and t tests were used to evaluate the impact of increased pulmonary symptoms on home spirometry frequency. The effect of the initiation of a new treatment, Elexacaftor/Tezacaftor/Ivacaftor, on use frequency over time was assessed in a subgroup of participants with repeated measures ANOVA. RESULTS During the observation period, a total of 604 people with CF were enrolled in the remote monitoring platform and 9930 home spirometry measurements were performed. After the initiation of home spirometry use, the number of users declined rapidly. One year after the initiation, 232 (54.2%) people with CF stopped using home spirometry. During the observation period, 67 (11.1%) users performed more than 20 measurements. Furthermore, the number of consistent home spirometry users decreased over time. After 600 days, only 1% of users had measured their lung function consistently every 31 days. Use frequency slightly increased during periods with increased pulmonary symptoms (ΔMean=0.45, t497.278=–4,197; P<.001) and showed an initial rise followed by a decrease after starting treatment with Elexacaftor/Tezacaftor/Ivacaftor (ΔMean=0.45, t497.278=–4,197; P<.001). CONCLUSIONS Consistent uptake of home spirometry in people with CF is low but increases around periods of changing symptoms. A clear strategy for the organization of remote care seemed to improve the long-term uptake of home spirometry. Nevertheless, home spirometry and its intensity are not a goal on their own but should be used as a tool to reach individual goals within local contexts.