Zekeriya Altaç

Zekeriya Altaç

Auto-generated profile, based on publicly available information

Zekeriya Altaç

Department of Mechanical Engineering, Eskişehir Osmangazi University

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2008 in International Journal of Heat and Fluid Flow
Verified
Journal Article
Closed access
NMNecati Mahír
Necati Mahír
ZAZekeriya Altaç
Zekeriya Altaç

1 September 2016 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
ZAZekeriya Altaç
Zekeriya Altaç
NUNihal Uğurlubilek
Nihal Uğurlubilek

23 January 2004 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
LEL. Berrin Erbay
L. Berrin Erbay
ZAZekeriya Altaç
Zekeriya Altaç
BSBirsen Sülüş
Birsen Sülüş

1 November 2011 in Applied Thermal Engineering
Verified
Journal Article
Closed access
ZBZerrin Bocu
Zerrin Bocu
ZAZekeriya Altac
Zekeriya Altac

1 August 2007 in Applied Thermal Engineering
Verified
Journal Article
Closed access
ZAZekeriya Altaç
Zekeriya Altaç
ÖKÖzen Kurtul
Özen Kurtul

31 December 2003 in Entropy
Verified
Journal Article
Open access
PDF file
LELatife Berrin Erbay
Latife Berrin Erbay
ZAZekeriya Altaç
Zekeriya Altaç
BSBirsen Sülüs
Birsen Sülüs
The entropy generation during transient laminar natural convection in a square enclosure is numerically investigated. Two different cases are considered. The enclosure is heated either completely or partially from the left side wall and cooled from the opposite side wall. The bottom and the top of the enclosure are assumed as insulated. The Boussinesq approximation is used in the natural convection modelling. The solutions are obtained from quiescent conditions proceeded through the transient up to the steady-state. The calculations are made for the Prandtl numbers 0.01 and 1.0 and Rayleigh numbers between 102-108. The entropy generation and the active places triggering the entropy generation are obtained for each case after the flow and thermal characteristics are determined. It is found that the active sites in the completely heated case are at the left bottom corner of the heated wall and the right top corner of the cooled wall at the same magnitudes. In the case of partial heating, however, the active site is observed at the top corner of the heated section especially at lower Pr and Ra values.