Michaël Petit

Michaël Petit

Auto-generated profile, based on publicly available information

Michaël Petit

PSE-SANTE/SDOS/LMDN. Centre de Cadarache

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2022 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
FVFrançois Vianna
François Vianna
GGGeraldine Gonon
Geraldine Gonon
KLKévin Lalanne
Kévin Lalanne
CAChristelle Adam-Guillermin
Christelle Adam-Guillermin
JBJean-François Bottollier-Depois
Jean-François Bottollier-Depois
VGVincent Gressier
Vincent Gressier

24 January 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
YTYann Clément Thibaut
Yann Clément Thibaut
GGG Gonon
G Gonon
JMJ S Martinez
J S Martinez
MPM Petit
M Petit
AVA Vaurijoux
A Vaurijoux
YPYANN PERROT
YANN PERROT
Objective . The mechanisms of radiation-induced DNA damage can be understood via the fundamental acquisition of knowledge through a combination of experiments and modeling. Currently, most biological experiments are performed by irradiating an entire cell population, whereas modeling of radiation-induced effects is usually performed via Monte Carlo simulations with track structure codes coupled to realistic DNA geometries of a single-cell nucleus. However, the difference in scale between the two methods hinders a direct comparison because the dose distribution in the cell population is not necessarily uniform owing to the stochastic nature of the energy deposition. Thus, this study proposed the MINAS TIRITH tool to model the distribution of radiation-induced DNA damage in a cell population. Approach . The proposed method is based on precomputed databases of microdosimetric parameters and DNA damage distributions generated using the Geant4-DNA Monte Carlo Toolkit. First, a specific energy z was assigned to each cell of an irradiated population for a particular absorbed dose D abs , following microdosimetric formalism. Then, each cell was assigned a realistic number of DNA damage events according to the specific energy z , respecting the stochastic character of its occurrence. Main results . This study validated the MINAS TIRITH tool by comparing its results with those obtained using the Geant4-DNA track structure code and a Geant4-DNA based simulation chain for DNA damage calculation. The different elements of comparison indicated consistency between MINAS TIRITH and the Monte Carlo simulation in case of the dose distribution in the population and the calculation of the amount of DNA damage. Significance . MINAS TIRITH is a new approach for the calculation of radiation-induced DNA damage at the cell population level that facilitates reasonable simulation times compared to those obtained with track structure codes. Moreover, this tool enables a more direct comparison between modeling and biological experimentation.

18 April 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ACAugusto Di Chicco
Augusto Di Chicco
ASAlix Sardet
Alix Sardet
MPMichaël Petit
Michaël Petit
RJRobert Jacqmin
Robert Jacqmin
VGVincent Gressier
Vincent Gressier
BSBrian Stout
Brian Stout

10 November 2023 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
YTYann Clément Thibaut
Yann Clément Thibaut
GGG Gonon
G Gonon
JMJ S Martinez
J S Martinez
MPM Petit
M Petit
RBR Babut
R Babut
YPYANN PERROT
YANN PERROT
In the domains of medicine and space exploration, refining risk assessment models for protecting healthy tissue from ionizing radiation is crucial. Understanding radiation-induced effects requires biological experimentations at the cellular population level and the cellular scale modeling using Monte Carlo track structure codes. We present MINAS TIRITH, a tool using Geant4-DNA Monte Carlo-generated databases to study DNA damage distribution at the cell population scale. It introduces a DNA damage location module and proposes a method to convert double-strand breaks (DSB) into DNA Damage Response foci. We evaluate damage location precision and DSB-foci conversion parameters. MINAS TIRITH’s accuracy is validated against γ -H2AX foci distribution from cell population exposed to monoenergetic neutron beams (2.5 or 15.1 MeV) under different configurations, yielding mixed radiation fields. Strong agreement between simulation and experimental results was found demonstrating MINAS TIRITH’s predictive precision in radiation-induced DNA damage topology. Additionally, modeling intercellular damage variability within a population subjected to a specific macroscopic dose identifies subpopulations, enhancing realistic fate models. This approach advances our understanding of radiation-induced effects on cellular systems for risk assessment improvement.

3 February 2021 in Nuclear Science and Engineering
Verified
Journal Article
Closed access
MPMichaël Petit
Michaël Petit
Concrete plays a major role in nuclear facilities as protection against radiation. However, its chemical composition, which is fundamental, is often unknown. Several concrete samples, extracted from the AMANDE-MIRCOM Institute for Radiological Protection and Nuclear Safety (IRSN) facility, were analyzed. Various simulations were performed in order to evaluate the neutron fluence behind a 40-cm-thick concrete wall. These simulations were compared to experimental measurements performed with a Bonner sphere spectrometer and a neutron survey meter. No set of parameters tested was able to produce a simulation accurately matching all the experimental results, but sensitivity studies on several parameters highlight that the three most sensitive parameters are the hydrogen content, the density, and the concrete inhomogeneity. To improve the agreement between the simulations and the measurements, the concrete inhomogeneity modeling should be studied further. Nevertheless, using concrete compositions that are close to reality, especially for hydrogen content, is crucial to correctly simulate neutron transport.

21 November 2023 in EPJ Web of Conferences
Verified
Journal Article
Open access
PDF file
DQDiane Quevauvillers
Diane Quevauvillers
LOLaurent Ottaviani
Laurent Ottaviani
MPMichael Petit
Michael Petit
CRChristelle Reynard-Carette
Christelle Reynard-Carette
Stilbene scintillators have now the capability to extend the neutron energy measurement from 100 keV to 1 MeV. To be used as spectrometers, scintillators have to be characterized in entire energy range covered. For the photon characterization, usual calibration source determined the calibration and the resolution function. To do the photon matrix, MCNP PTRAC simulations were done between 59 keV up to 7 MeV. Using MCNP PTRAC allows the calculation of the photon response matrix from the tracking detail of the electron energy deposition in the crystal, including the effect of the Aluminum protection around. Resolution and sensibility obtained from gamma sources are applied later to the calculated photon matrix. For neutron characterization, Time-Of-Flight measurements on white neutron spectra were realized. However, the fluence reference on these spectra begins at 1 MeV. So, the shape of the response function was measured using stilbene scintillators on 100 keV1 MeV decade. After, the monoenergetic neutron reference of AMANDE facility was used to give neutron fluence normalization below 1 MeV. This method could characterize these scintillators for neutron energy from 100 keV up to 22 MeV.