Young-Kil Shin

Young-Kil Shin

Auto-generated profile, based on publicly available information

Young-Kil Shin

School of Electronic and Information Engineering, Kunsan National University, San 68, Miryong-Dong, Kunsan, Chonbuk, 573-701, Korea

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2009 in NDT & E International
Verified
Journal Article
Closed access
YSYoung-Kil Shin
Young-Kil Shin
DCDong-Myung Choi
Dong-Myung Choi
YKYoung-Joo Kim
Young-Joo Kim
SLSeung-Seok Lee
Seung-Seok Lee

1 June 2000 in NDT & E International
Verified
Journal Article
Closed access
SSSung-Jin Song
Sung-Jin Song
YSYoung-Kil Shin
Young-Kil Shin

1 March 1997 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
YSYoung-Kil Shin
Young-Kil Shin

10 May 2008 in Modern Physics Letters B
Verified
Journal Article
Closed access
PDF file
YKYoung Joo Kim
Young Joo Kim
BABong Young Ahn
Bong Young Ahn
SLSeung-Seok Lee
Seung-Seok Lee
YSYoung-Kil Shin
Young-Kil Shin

15 August 2004 in Key Engineering Materials
Verified
Journal Article
Closed access
PDF file
YSYoung Kil Shin
Young Kil Shin
JLJeong Ho Lee
Jeong Ho Lee
MSMyung Ho Song
Myung Ho Song

1 January 2001 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
YSYoung-Kil Shin
Young-Kil Shin
TCTae-Eon Chung
Tae-Eon Chung
WLWilliam Lord
William Lord
As steam generator (SG) tubes have aged, new and subtle degradations have appeared. Most of them start growing from outside the tubes. Since outer diameter defects might not be detected by conventional eddy current testing due to skin effect phenomena, this paper studies the feasibility of using the remote field eddy current (RFEC) technique, which has shown equal sensitivity to inner diameter (ID) and outer diameter (OD) defects in ferromagnetic pipe inspection. Finite element modeling studies show that the operating frequency needs to be increased up to a few hundred kHz in order for RFEC effects to occur in the nonmagnetic SG tube. The proper distance between exciter and sensor coils is also found to be 1.5 OD, which is half of the distance used in ferromagnetic pipe inspection. The resulting defect signals show equal sensitivity to ID and OD defects. These results demonstrate superior capability of the proposed RFEC probe compared to the differential ECT probe in detecting OD defects.