Mark Arthur

Mark Arthur

Auto-generated profile, based on publicly available information

Mark Arthur

University of Arizona, Phoenix, Arizona

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
JDJonathan Day
Jonathan Day
AFAmanda N. Fletcher
Amanda N. Fletcher
MMMorgan Motsay
Morgan Motsay
MMMaggie Manchester
Maggie Manchester
MAMark Arthur
Mark Arthur
LSLew C. Schon
Lew C. Schon
Background: While most total ankle arthroplasty (TAA) procedures utilize an anterior approach for implantation, the Zimmer Biomet Trabecular Metal implant is unique in that it utilizes a lateral transfibular approach. We present the largest mid-term study to date to analyze the implant survivorship and clinical and radiographic outcomes of transfibular TAA at a minimum 5-year follow-up. Methods: We retrospectively identified and evaluated 130 ankles (122 patients; mean age, 60.8 years; 50% female) with a mean follow-up of 5.9 years (range, 5.0 to 10.1 years) after primary TAA performed between October 2012 and December 2018. Patient-reported outcome measures (PROMs) included the 12-item Short Form Health Survey (SF-12) Physical Component Summary (PCS) and Mental Component Summary (MCS), Ankle Osteoarthritis Scale (AOS) for pain and disability, and visual analog scale (VAS) for pain. Radiographic measurements for range of motion, coronal and sagittal alignment, and implant subsidence were evaluated. The presence of periprosthetic radiolucency was determined using a 12-zone classification system. Adverse events were reported using the Canadian Orthopaedic Foot and Ankle Society (COFAS) Reoperation Coding System (CROCS). Results: The cohort had mean postoperative values of 41.5 for the SF-12 PCS, 54.9 for the SF-12 MCS, 2.3 for VAS pain, 19.1 for AOS pain, and 28.5 for AOS disability. The postoperative tibiotalar range of motion was 7.5° of dorsiflexion and 17.3° of plantar flexion. A total of 42 valgus ankles (mean coronal tibiotalar angle, 10.4°; range, 1.0° to 25.3°) and 44 varus ankles (mean, −9.1°; range, −1.0° to −25.0°) were corrected to neutral. Twenty-six ankles (20%) had 1 zone of radiolucency, and none of the ankles had >7 zones. There were 3 cases of cysts (2.3%) and 0 cases of subsidence, septic or aseptic loosening, or fibular nonunion. Adverse events occurred in 47 ankles (36.2%) at a mean of 26.7 months, with the most common reoperation being medial gutter debridement (22 ankles; 16.9%). There were 2 ankles (1.5%) with acute infection treated with debridement, antibiotics, and polyethylene exchange with metal component retention. Overall implant survivorship, defined as retention of the metal components, was 100% at the time of final follow-up. Conclusions: The clinical and radiographic data in this study suggest that transfibular TAA is an effective and durable treatment option for end-stage ankle arthritis, with excellent mid-term implant survivorship. Periprosthetic radiolucency was limited and did not lead to implant subsidence or loosening. The most common reoperation was medial gutter debridement. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

20 May 2021 in International Journal Of Impotence Research
Verified
Journal Article
Closed access
PDF file
KHKarim Hanna
Karim Hanna
MAMark Arthur
Mark Arthur
CWCharles Welliver
Charles Welliver

5 October 2020 in Case Reports in Urology
Verified
Journal Article
Open access
PDF file
MAMark Arthur
Mark Arthur
JCJonathan Canete
Jonathan Canete
CWCharles Welliver
Charles Welliver
Inflatable penile prosthesis (IPP) involves placement of the fluid reservoir into an abdominal or pelvic location. While the space of Retzius (SOR) was the preferred site for many years, the change from open to robotic prostatectomy made this space less desirable due to the violation of the peritoneum with the robotic approach. Other factors like previous abdominal or pelvic surgeries (particularly inguinal hernia repair with mesh) may also require a change in location of the reservoir during IPP placement. In this report, we discuss a previously undescribed result of alternative reservoir placement (ARP) with erosion of the reservoir through the colon and out of the anus in a man with multiple previous abdominal surgeries. Management of this clinical problem is also discussed.