1 February 2012 in Epilepsy Research
14 November 2012 in ISRN Neurology
Purpose. To evaluate the clinical utility of dense array electroencephalography (dEEG) for detecting and localizing interictal spikes in temporal lobe epilepsy. Methods. Simultaneous invasive and noninvasive recordings were performed across two different groups. (1) The first group underwent both noninvasive recording with 128 channels of (scalp) dEEG and invasive sphenoidal electrode recording. (2) The second group underwent both noninvasive recording with 256 channels of (scalp) dEEG and invasive intracranial EEG (icEEG) involving coverage with grids and strips over the lateral and mesial temporal lobe. A noninvasive to noninvasive comparison was made comparing the overall spike detection rate of the dEEG to that of conventional 10/20 EEG. A noninvasive to invasive comparison was made comparing the spike detection rate of dEEG to that of conventional 10/20 EEG plus sphenoidal electrodes. And finally, a noninvasive to invasive evaluation measuring the source localization ability of the dEEG using the icEEG as validation. Results. In the 128-channel dEEG study (1), 90.4% of the interictal spikes detected by the dEEG were not detected in the 10/20 montage. 91% of the dEEG-detected spikes were accurately localized to the medial temporal lobe. In the 256-channel dEEG study (2), 218 of 519 interictal spikes (42%) were detected by dEEG. 85% of these spikes were accurately localized to the medial temporal lobe, close to the position confirmed by subdural electrodes. Conclusion. Dense array EEG may provide more precise information than conventional EEG and has a potential for providing an alternative to sphenoidal electrode monitoring in patients with temporal lobe epilepsy.
1 January 2013 in Frontiers in Neurology
Rationale: Dense array EEG (dEEG) evenly covers the whole head surface with over 100 channels contributing to more accurate electrical source imaging due to the higher spatial and temporal resolution. Several studies have shown the clinical utility of dEEG in presurgical clinical evaluation of epilepsy. However validation studies measuring the accuracy of dEEG source imaging are still needed. This can be achieved through simultaneously recording both scalp dEEG with intracranial electrodes (icEEG), which is considered as the true measure of cortical activity at the source. The purpose of this study is to evaluate the accuracy of 256-channel dEEG electrical source estimation for interictal spikes. Methods: Four patients with medically refractory neocortical epilepsy, all surgical candidates, underwent subdural electrode implantation to determine ictal onset and define functional areas. One patient showed a lesion on the magnetic resonance imaging in the right parietal lobe. The patient underwent simultaneous recording of interictal spikes by both scalp 256-channelsvdEEG and icEEG. The dEEG was used to non-invasively estimate the source of the interictal spikes detected by the 256-channel dEEG array, which was then compared to the activity measured directly at the source by the icEEG. Results: From the four patients, a total of 287 interictal spikes were measured with the icEEG. One hundred fifty-five of the 287 spikes (54%) were visually detected by the dEEG upon examination of the 256 channel head surface array. The spike amplitudes detected by the 256-channel dEEG correlated with icEEG spike amplitudes (p < 0.01). All spikes detected in dEEG were localized to the same lobe correctly. Conclusion: Our study demonstrates that 256-channel dEEG can reliably detect interictal spikes and localize them with reasonable accuracy. Two hundred fifty-six-channel dEEG may be clinically useful in the presurgical workup for epilepsy and also reduce the need for invasive EEG evaluation.
1 January 2013 in Frontiers in Neurology
Corrigendum: Dense Array EEG Source Estimation in Neocortical Epilepsy