Radu Darie

Radu Darie

Auto-generated profile, based on publicly available information

Radu Darie

Brown University School of Engineering

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2025 in Journal of Neural Engineering
Verified
Journal Article
Open access
SPSamuel R Parker
Samuel R Parker
JCJonathan Scott Calvert
Jonathan Scott Calvert
RDRadu Darie
Radu Darie
JJJaeson Jang
Jaeson Jang
LGLakshmi Narasimhan Govindarajan
Lakshmi Narasimhan Govindarajan
BMBryan L McLaughlin
Bryan L McLaughlin
Objective. Epidural electrical stimulation (EES) has shown promise as both a clinical therapy and research tool for studying nervous system function. However, available clinical EES paddles are limited to using a small number of contacts due to the burden of wires necessary to connect each contact to the therapeutic delivery device, limiting the treatment area or density of epidural electrode arrays. We aimed to eliminate this burden using advanced on-paddle electronics. Approach. We developed a smart EES paddle with a 60-electrode programmable array, addressable using an active electronic multiplexer embedded within the electrode paddle body. The electronics are sealed in novel, ultra-low profile hermetic packaging. We conducted extensive reliability testing on the novel array, including a battery of ISO 10993-1 biocompatibility tests and determination of the hermetic package leak rate. We then evaluated the EES device in vivo, placed on the epidural surface of the ovine lumbosacral spinal cord for 15 months. Main results. The active paddle array performed nominally when implanted in sheep for over 15 months and no device-related malfunctions were observed. The onboard multiplexer enabled bespoke electrode arrangements across, and within, experimental sessions. We identified stereotyped responses to stimulation in lower extremity musculature, and examined local field potential responses to EES using high-density recording bipoles. Finally, spatial electrode encoding enabled machine learning models to accurately perform EES parameter inference for unseen stimulation electrodes, reducing the need for extensive training data in future deep models. Significance. We report the development and chronic large animal in vivo evaluation of a high-density EES paddle array containing active electronics. Our results provide a foundation for more advanced computation and processing to be integrated directly into devices implanted at the neural interface, opening new avenues for the study of nervous system function and new therapies to treat neural injury and dysfunction.

2 June 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
SPSamuel R. Parker
Samuel R. Parker
JCJonathan Scott Calvert
Jonathan Scott Calvert
RDRadu Darie
Radu Darie
JJJaeson Jang
Jaeson Jang
LGLakshmi Narasimhan Govindarajan
Lakshmi Narasimhan Govindarajan
BMBryan L. McLaughlin
Bryan L. McLaughlin
Objective: Epidural electrical stimulation (EES) has shown promise as both a clinical therapy and research tool for studying nervous system function. However, available clinical EES paddles are limited to using a small number of contacts due to the burden of wires necessary to connect each contact to the therapeutic delivery device, limiting the treatment area or density of epidural electrode arrays. We aimed to eliminate this burden using advanced on-paddle electronics. Approach: We developed a smart EES paddle with a 60-electrode programmable array, addressable using an active electronic multiplexer embedded within the electrode paddle body. The electronics are sealed in novel, ultra-low profile hermetic packaging. We conducted extensive reliability testing on the novel array, including a battery of ISO 10993-1 biocompatibility tests and determination of the hermetic package leak rate. We then evaluated the EES device in vivo, placed on the epidural surface of the ovine lumbosacral spinal cord for 15 months. Main results: The active paddle array performed nominally when implanted in sheep for over 15 months and no device-related malfunctions were observed. The onboard multiplexer enabled bespoke electrode arrangements across, and within, experimental sessions. We identified stereotyped responses to stimulation in lower extremity musculature, and examined local field potential responses to EES using high-density recording bipoles. Finally, spatial electrode encoding enabled machine learning models to accurately perform EES parameter inference for unseen stimulation electrodes, reducing the need for extensive training data in future deep models. Significance: We report the development and chronic large animal in vivo evaluation of a high-density EES paddle array containing active electronics. Our results provide a foundation for more advanced computation and processing to be integrated directly into devices implanted at the neural interface, opening new avenues for the study of nervous system function and new therapies to treat neural injury and dysfunction.

24 February 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
RDRadu Darie
Radu Darie
SPSamuel R. Parker
Samuel R. Parker
JCJonathan Scott Calvert
Jonathan Scott Calvert
ETEkta Tiwari
Ekta Tiwari
NANaser Abdelrahman
Naser Abdelrahman
DBDavid A. Borton
David A. Borton
Modern neuroelectronic interfaces have shown great potential to diagnose conditions, address neurological dysfunction, and advance neuroscientific knowledge. However, neural interface systems today require tethered connections that restrict mobility, prevent testing across ecological contexts, and inhibit clinical translation to at-home use. Fully implantable commercial systems have previously been developed, but exhibit significant constraints, including a bulky design, limited modularity, low bandwidth, or unidirectional communication (e.g. deep brain stimulation systems, DBS; spinal cord stimulation systems, SCS). Here, we have developed the Modular Bionic Interface (MBI), a system composed of a fully implantable device and a worn unit for high-bandwidth, bidirectional interfacing with the nervous system. The MBI can record high fidelity electrophysiological signals and deliver spatiotemporally modulated electrical stimulation for clinical and research purposes through flexible interaction with third party implantable devices. We performed benchtop evaluation to validate the recording and stimulation capabilities of the MBI across a diverse range of inputs and outputs. We then evaluated the MBI system in vivo through chronic implantation within a sheep, where results were stable for the length of evaluation, over three months. While connected to an actively powered, third-party high-resolution spinal cord stimulation electrode array, the MBI system was able to deliver stimulation to evoke lower extremity motor responses and record spinal compound action potentials evoked by peripheral nerve and spinal stimulation. Through rigorous evaluation, we demonstrate a fully implantable system with a small footprint capable of high-resolution, bi-directional communication with the nervous system via modular connections to third-party devices. We expect that modular devices will further our ability to treat complex neurological disease and injury.

18 March 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
LSLeo Steiner
Leo Steiner
RDRadu Darie
Radu Darie
ALAudrey Lindsay
Audrey Lindsay
HTHua-An Tseng
Hua-An Tseng
IWIngrid van Welie
Ingrid van Welie
XHXue Han
Xue Han
The Subthalamic Nucleus (STN) regulates movement and is an important clinical target for deep brain stimulation (DBS) in Parkinson’s Disease (PD). However, it remains unclear how dopamine loss and DBS influence STN gait encoding. We performed simultaneous recordings from multiple neurons and intermittent DBS in the STN of healthy and dopamine depleted PD mice during voluntary locomotion. We found that dopamine loss resulted in gait deficits manifested as altered stride length of both hindlimbs and forelimbs, which were rescued by intermittent DBS. Furthermore, dopamine loss exaggerated movement encoding of STN population dynamics, and elevates individual STN spiking during movement and beta-rhythmic firing at rest. Despite an overall increase in the fraction of neuron activated by movement, individual neurons gait encoding properties remain similar between healthy and PD mice. While DBS suppressed firing in both healthy and PD mice, it selectively reduced STN beta-rhythmic spiking, desynchronized STN networks, and rescued gait deficits associated with the loss of dopamine. These results suggest that pathological activation and beta synchronization of the STN contributes to motor deficits related to PD, and DBS-induced reduction of beta rhythmic spiking and STN network desynchronization contribute to the therapeutic effects of DBS in PD.

18 June 2026 in Journal of Neural Engineering
Verified
Journal Article
Closed access
RDRadu Darie
Radu Darie
SPSamuel R Parker
Samuel R Parker
JCJonathan Scott Calvert
Jonathan Scott Calvert
ETEkta Tiwari
Ekta Tiwari
NANaser Abdelrahman
Naser Abdelrahman
DBDavid A. Borton
David A. Borton
Objective. Modern neuroelectronic interfaces have shown great potential to diagnose conditions, address neurological dysfunction, and advance neuroscientific knowledge. However, neural interface systems today require tethered connections that restrict mobility, prevent testing across ecological contexts, and inhibit clinical translation to at-home use. Fully implantable commercial systems have previously been developed, but exhibit significant constraints, including limited modularity, low bandwidth, or unidirectional communication. We aimed to close this gap by developing a neuroelectronic interface that can be deployed flexibly with a variety of third-party neural probes. Approach. We have developed the Modular Bionic Interface (MBI), a system composed of a fully implantable device and a worn unit for high-bandwidth, bidirectional interfacing with the nervous system. The MBI can record high fidelity electrophysiological signals and deliver spatiotemporally modulated electrical stimulation for clinical and research purposes through flexible interaction with third party implantable devices. Main results. We performed benchtop evaluation to validate the recording and stimulation capabilities of the MBI across a diverse range of inputs and outputs. We then evaluated the MBI system in vivo through chronic implantation within a sheep, where results were stable for the length of evaluation, over six months. While connected to an actively powered, third-party high-resolution spinal cord stimulation electrode array, the MBI system was able to deliver stimulation to evoke lower extremity motor responses and record spinal compound action potentials evoked by peripheral nerve and spinal stimulation. Significance. We demonstrate a fully implantable system with a small footprint capable of high-resolution, bi-directional communication with the nervous system via modular connections to third-party devices. We expect that modular devices will further our ability to treat complex neurological disease and injury.