Moïse Godfroy Kwato Njock

Moïse Godfroy Kwato Njock

Auto-generated profile, based on publicly available information

Moïse Godfroy Kwato Njock

Centre for Atomic Molecular Physics and Quantum Optics (CEPAMOQ), Faculty of Science, University of Douala, P.O. Box 8580 Douala, Cameroon

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
JIJoseph Emmanuel NDJANA NKOULOU II
Joseph Emmanuel NDJANA NKOULOU II
LELouis Ngoa Engola
Louis Ngoa Engola
Masahiro HosodaMasahiro Hosoda
Masahiro Hosoda
DBDaniel Bongue
Daniel Bongue
TSTakahito Suzuki
Takahito Suzuki
Shinji TokonamiShinji Tokonami
Shinji Tokonami
Indoor radon (Rn), thoron (Tn) and thoron progeny (TnP) were simultaneously measured in the gold mining areas of Betare-Oya using RADUET detectors and TnP monitors. Rn and Tn concentrations range between 88-282 and 4-383 Bq m-3, respectively, with the arithmetic means of 133 ± 39 and 93 ± 76 Bq m-3. The 76% of houses for Rn and 25% for Tn exceed the WHO reference level of 100 Bq m-3 and 3% of the houses exceed the ICRP threshold of 300 Bq m-3. The equilibrium equivalent thoron concentration ranges between 1 and 19 Bq m-3 with a mean value of 6 ± 4 Bq m-3. The thoron equilibrium factor ranges between 0.01 and 0.55 with arithmetic mean of 0.11, higher than the world average value of 0.02 given by UNSCEAR. The total inhalation dose due to Rn, Tn and their progeny ranges between 1.8 and 6.2 mSv y-1 with the arithmetic mean of 3.8 ± 1.1 mSv y-1.

20 August 2008 in Journal of Radiological Protection
Verified
Journal Article
Closed access
MNM Ngachin
M Ngachin
MGM Garavaglia
M Garavaglia
CGC Giovani
C Giovani
ANA Nourreddine
A Nourreddine
MNM G Kwato Njock
M G Kwato Njock
Leonel E. LagosLeonel E. Lagos
Leonel E. Lagos
This work deals with the measurement of radioactivity and radon exhalation rate from building materials manufactured in Douala city from geological materials. Nine types of building material were surveyed for their natural radioactivity contents using high-resolution gamma-ray spectrometry. The activity concentrations for (226)Ra, (232)Th and (40)K varied from 11.5 to 49 Bq kg(-1), 16 to 37 Bq kg(-1) and 306 to 774 Bq kg(-1), respectively. The absorbed dose rate in the samples investigated at 1 m above ground level ranged from 28.5 to 66.6 nGy h(-1). External and internal hazard indices were also estimated as defined by the European Commission. The Ra equivalents of the materials studied ranged from 57.5 to 133 Bq kg(-1) and are much smaller than the recommended limit of 370 Bq kg(-1) for construction materials for dwellings. Polycarbonate nuclear track detectors (NTDs), type CR-39, were used for measuring the radon concentration from different materials. In fact, knowledge of the radon exhalation rate from building materials is important for understanding the individual contribution of each material to the total indoor radon exposure. Samples were hermetically closed in glass vessels and the radon growth was followed as a function of time. The radon exhalation rate was therefore derived from the experimental measurement of alpha-track densities. The radon exhalation varied from (5.77 +/- 0.06) x 10(-5) to (7.61 +/- 0.07) x 10(-5) Bq cm(-2) h(-1) in bricks, from (5.79 +/- 0.05) x 10(-5) to (11.6 +/- 0.12) x 10(-5) in tiles, and was (6.95 +/- 0.03) x 10(-5) Bq cm(-2) h(-1) in concrete. A correlation (correlation coefficient approximately 0.8) was found between radium concentration measured with a HPGe detector and the radon exhalation rate obtained using nuclear track detectors.

5 December 2023 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
FHFelix Haman
Felix Haman
CSCebastien Joel GUEMBOU SHOUOP
Cebastien Joel GUEMBOU SHOUOP
DODavid Kpeglo Okoh
David Kpeglo Okoh
DBDaniel Bongue
Daniel Bongue
DTDorine Flore Tiomene
Dorine Flore Tiomene
MNMoïse Godfroy Kwato Njock
Moïse Godfroy Kwato Njock

22 January 2013 in Physical Review A
Verified
Journal Article
Closed access
HNHugues Merlain Tetchou Nganso
Hugues Merlain Tetchou Nganso
AHAliou Hamido
Aliou Hamido
MNMoïse Godfroy Kwato Njock
Moïse Godfroy Kwato Njock
YPYuri Vladimirovich Popov
Yuri Vladimirovich Popov
BPBernard Piraux
Bernard Piraux
With the help of the solution of the time-dependent Schrödinger equation in momentum space, we study the above-threshold ionization spectrum resulting from the interaction of atomic hydrogen with an infrared and XUV short laser pulses. Our calculations are based on a model where the kernel of the nonlocal Coulomb potential is replaced by a finite sum of N symmetric separable potentials, each of them supporting one bound state of atomic hydrogen. Here, we consider only the case of 1s, 2s, and 2p states. Thus, the theory fully accounting for the important 1s–2p transition, explains the photoelectron spectrum as well as the total ionization probability for the resonant case. We compared the results given by our theory with the numerical solutions of the time-dependent Schrödinger equation. DOI: http://dx.doi.org/10.1103/PhysRevA.87.013420 ©2013 American Physical Society

19 May 2022 in Radiation Effects and Defects in Solids
Verified
Journal Article
Closed access
PDPatricia-Laurelle Degbe
Patricia-Laurelle Degbe
CSCebastien Joel GUEMBOU SHOUOP
Cebastien Joel GUEMBOU SHOUOP
DBDaniel Bongue
Daniel Bongue
MBMerylle Glawdys Beyinda
Merylle Glawdys Beyinda
MMMaurice Ndontchueng Moyo
Maurice Ndontchueng Moyo
MNMoïse Godfroy Kwato Njock
Moïse Godfroy Kwato Njock
This study used the Energy Dispersive X-Ray Fluorescence (EDXRF) spectrometry to determine the elemental composition of nineteen rock samples from the Pouma sub-division of Cameroon. The major chemical elements found in these samples were compounds of SiO2, Al2O3, K2O, Fe2O3, CaO, and P2O5. The elemental characterization of the investigated samples was used to evaluate the mass attenuation coefficients of the quartzite rocks using the XCOM analytical calculation software and the GEANT4 Monte Carlo computational toolkit. The mass attenuation coefficients were calculated for the average concentration values of the samples from different sampling sites. The mass attenuation coefficients generated using the GEANT4 simulation have uncertainties less than 4% in all the four investigated sampling sites compared to the analytical results. The results of the simulation showed that the calculated mass attenuation coefficients are in good agreement with the theoretical data. Therefore, the developed GEANT4 code for radiation properties assessment of rocks is accurate and could be used by scientists worldwide. The determination of these mass attenuation coefficients is consequently the unveiling of radiation shielding properties of the investigated material.

19 February 2014 in Physical Review A
Verified
Journal Article
Closed access
ZBZachée Bona
Zachée Bona
HNHugues Merlain Tetchou Nganso
Hugues Merlain Tetchou Nganso
TEThierry Blanchard Ekogo
Thierry Blanchard Ekogo
MNMoïse Godfroy Kwato Njock
Moïse Godfroy Kwato Njock
A fully relativistic multipole scheme is formulated to study two-photon emission processes in hydrogenlike ions with an infinitely heavy, pointlike, and spinless nucleus of charge up to 100. By making use of the Sturmian expansion of the Dirac-Coulomb Green function of the first order constructed by Szmytkowski, closed-form expressions are derived for arbitrary multipole channels. In the nonrelativistic limit, well-known formulas established previously are retrieved. For the sake of assessing the effectiveness of our approach, numerical applications are then carried out for two-photon decay rates of the selected $2{s}_{1/2}$ and $2{p}_{1/2}$ atomic states. To this end, radial integrals, the most crucial quantities involved in the matrix elements, are treated with great care by means of two suitable techniques that agree with each other quite closely so that very accurate values are obtained regardless of the choice of parameters, such as radial quantum numbers and orders of spherical Bessel functions of the first kind. In addition, the convergence and stability of computations are checked in connection with the intermediate-state summation, which appears within the second-order perturbation theory. As expected, the gauge invariance of our fully relativistic multipole numbers is confirmed. Relativistic effects, and the influence of the negative spectrum of the complete set of Dirac-Coulomb Sturmians of first order and retardation truncations in the transition operator are examined. Finally, a comparison is undertaken of our two-photon relativistic calculations with refined predictions of other authors based on finite basis-set methods widely employed over the past decades.