Matthew Wester

Matthew Wester

Auto-generated profile, based on publicly available information

Matthew Wester

Department of Bioengineering, University of Illinois at Urbana–Champaign

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2025 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
JLJongwon Lim
Jongwon Lim
AVAn Bao Van
An Bao Van
KKKatherine Koprowski
Katherine Koprowski
MWMatthew Wester
Matthew Wester
EVEnrique Valera
Enrique Valera
RBRashid Bashir
Rashid Bashir
Rapid and accurate detection of DNA from disease-causing pathogens is essential for controlling the spread of infections and administering timely treatments. While traditional molecular diagnostics techniques like PCR are highly sensitive, they include nucleic acid amplification and many need to be performed in centralized laboratories, limiting their utility in point-of-care settings. Recent advances in CRISPR-based diagnostics (CRISPR-Dx) have demonstrated the potential for highly specific molecular detection, but the sensitivity is often constrained by the slow trans-cleavage activity of Cas enzymes, necessitating preamplification of target nucleic acids. In this study, we present a CRISPR-Cascade assay that overcomes these limitations by integrating a positive feedback loop that enables nucleic acid amplification-free detection of pathogenic DNA at atto-molar levels and achieves a signal-to-noise ratio greater than 1.3 within just 10 min. The versatility of the assay is demonstrated through the detection of bloodstream infection pathogens, including Methicillin-Sensitive Staphylococcus aureus (MSSA), Methicillin-Resistant Staphylococcus aureus (MRSA), Escherichia coli , and Hepatitis B Virus (HBV) spiked in whole blood samples. Additionally, we introduce a multiplexing OR-function logic gate, further enhancing the potential of the CRISPR-Cascade assay for rapid and accurate diagnostics in clinical settings. Our findings highlight the ability of the CRISPR-Cascade assay to provide highly sensitive and specific molecular detection, paving the way for advanced applications in point-of-care diagnostics and beyond.

29 May 2026 in Nature Reviews Bioengineering
Verified
Journal Article
Closed access
MWMatthew Wester
Matthew Wester
JLJongwon Lim
Jongwon Lim
MGMohammadreza Ghaderinia
Mohammadreza Ghaderinia
KKKatherine Koprowski
Katherine Koprowski
AVAn Bao Van
An Bao Van
RBRashid Bashir
Rashid Bashir

21 May 2026 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
JLJongwon Lim
Jongwon Lim
AVAn Bao Van
An Bao Van
MWMatthew Wester
Matthew Wester
KKKatherine Koprowski
Katherine Koprowski
EVEnrique Valera
Enrique Valera
RBRashid Bashir
Rashid Bashir
Autocatalytic CRISPR architecture offers amplification-free nucleic acid detection by directly linking target recognition to self-reinforcing ribonucleoprotein (RNP) generation. However, spontaneous background activation remains a key barrier, because strand invasion or unwinding events can initiate unintended amplification and diminish assay specificity. Here, we introduce a dual-blocking CRISPR-Cascade design that independently cages both the guide RNA and trigger DNA, establishing an intrinsic AND gate to raise the effective kinetic barrier for unintended RNP formation. This strategy suppresses leakage by approximately 3- to 18-fold relative to single blocking configurations in full Cascade reactions, while preserving rapid detection (10 min), achieving single-copy sensitivity, and enabling quantitative detection. When paired with a competitive guide RNA decoy, the system further reduces background signals without affecting true target detection. Finally, we demonstrate robust Methicillin-resistant Staphylococcus aureus detection from whole blood in under 40 min including the sample purification and extraction. These results establish dual-blocking as a generalizable molecular gating framework for constructing leakage-resistant, amplification-free CRISPR systems suitable for rapid and decentralized diagnostics.

23 March 2025 in SLAS Technology
Verified
Journal Article
Open access
JLJongwon Lim
Jongwon Lim
KKKatherine Koprowski
Katherine Koprowski
MWMatthew Wester
Matthew Wester
EVEnrique Valera
Enrique Valera
RBRashid Bashir
Rashid Bashir
Rapid and accurate detection of pathogenic microorganisms in blood is critical for diagnosing life-threatening conditions such as bloodstream infections (BSIs). Current methods for the detection and identification of bacteria from large volumes of blood (5 mL) involve culture steps followed by DNA extraction/purification/concentration and Polymerase Chain Reaction (PCR)-based nucleic acid amplification. DNA extraction and amplification directly from blood samples is hampered by the complexity of the blood matrix, resulting in time-consuming and labor-intensive processes. This review delves into recent advancements in molecular diagnostics based on blood drying, coined as 'biphasic reaction', and highlights this new technique that attempts to overcome the limitations of traditional sample preparation and amplification processes. The biphasic blood drying method, in combination with isothermal amplification methods such as loop-mediated isothermal amplification (LAMP) or recombinase polymerase amplification (RPA), has recently been shown to improve the sensitivity of detection of bacterial, viral, and fungal pathogens from ∼1 mL of whole blood, while minimizing DNA loss and avoiding the use of extraction/purification/concentration kits. Furthermore, the biphasic approach in combination with LAMP has been shown to be a culture-free method capable of detecting bacteria in clinical samples with a sensitivity of ∼1 CFU/mL in ∼2.5 h. This represents a significant reduction in detection and identification time compared to current clinical procedures based on bacterial culture prior to PCR amplification. This review paper aims to be a guide to identify new opportunities for future advancements and applications of the biphasic technology.

4 March 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
MWMatthew Wester
Matthew Wester
JLJongwon Lim
Jongwon Lim
AVAn Bao Van
An Bao Van
KKKatherine Koprowski
Katherine Koprowski
EVEnrique Valera
Enrique Valera
RBRashid Bashir
Rashid Bashir
CRISPR-Cas-based diagnostics utilize the Cas enzyme’s trans-cleavage activity to generate signal and have become popular platforms for sensitive nucleic acid detection. Recently, autocatalytic systems have been demonstrated to improve the time to response and sensitivity in some cases. However, mechanistic description of these assays is limited and optimization relies on simple trial-and-error. In this work, we present the first comprehensive kinetic model that integrates all major biochemical processes involved in these assays, including cleavage reactions, nucleic acid equilibrium kinetics, inhibition of trans-cleavage by single-stranded DNA, and degradation of single-stranded reaction components. We discuss the biochemical foundations and implementation of the ordinary differential equation model, which is built for adaptation to different reaction schemes. We use the full model to investigate the role of nucleic acid stability in assay performance for a typical nucleic acid design and show that our model demonstrates inhibition effects consistent with experimental data. We describe the reaction behavior, derive a simplified analytical model and compare its performance to the full analytical model. Finally, we demonstrate tools developed for rapid in silico optimization to guide the rational design of future target-amplification-free CRISPR-Cas-based autocatalysis assays.

16 October 2024 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
MWMatthew Wester
Matthew Wester
JLJongwon Lim
Jongwon Lim
LKLiliana Khaertdinova
Liliana Khaertdinova
SDSriya Darsi
Sriya Darsi
NDNeel Donthamsetti
Neel Donthamsetti
RBRashid Bashir
Rashid Bashir
Hanging drop cultures provide a favorable environment for the gentle, gel-free formation of highly uniform three-dimensional cell cultures often used in drug screening applications. Initial cell numbers can be limited, as with primary cells provided by minimally invasive biopsies. Therefore, it can be beneficial to divide cells into miniaturized arrays of hanging drops to supply a larger number of samples. Here, we present a framework for the miniaturization of hanging drop networks to nanoliter volumes. The principles of a single hanging drop are described and used to construct the fundamental equations for a microfluidic system composed of multiple connected drops. Constitutive equations for the hanging drop as a nonlinear capacitive element are derived for application in the electronic-hydraulic analogy, forming the basis for more complex, time-dependent numerical modeling of hanging drop networks. This is supplemented by traditional computational fluid dynamics simulation to provide further information about flow conditions within the wells. A fabrication protocol is presented and demonstrated for creating transparent, microscale arrays of pinned hanging drops. A custom interface, pressure-based fluidic system, and environmental chamber have been developed to support the device. Finally, fluid flow on the chip is demonstrated to align with expected behavior based on the principles derived for hanging drop networks. Challenges with the system and potential areas for improvement are discussed. This paper expands on the limited body of hanging drop network literature and provides a framework for designing, fabricating, and operating these systems at the microscale.