19 July 2022 in EP Europace
The cornerstone of pulmonary vein (PV) isolation (PVI) is a wide-area circumferential ablation (WACA) resulting in an antral PVI area. Pulsed-field ablation (PFA) is a new nonthermal ‘single-shot’ PVI technique resulting in well-characterized posterior isolation areas. However, information on circumferential PVI area is lacking. Thus, we sought to characterize the circumferential antral PVI areas after PFA-PVI. Atrial fibrillation (AF) patients underwent fluoroscopy-guided PVI with a pentaspline PFA catheter. Ultra-high-density voltage maps using a 20-polar circular mapping catheter were created before and immediately after PVI to identify and quantify (i) insufficient isolation areas per antral PV segment (10-segment model) and (ii) enlarged left atrial (LA) isolation areas (beyond the antral PV segments) per LA region (8-region model). The PFA-PVI with pre- (5469 ± 1822 points) and post-mapping (6809 ± 2769 points) was performed in 40 consecutive patients [age 62 ± 6 years, 25/40 (62.5%) paroxysmal AF]. Insufficient isolation areas were located most frequently in the anterior antral PV segments of the left PVs (62.5–77.5% of patients) with the largest extent (median ≥0.4 cm2) located in the same segments (segments 2/5/8). Enlarged LA isolation areas were located most frequently and most extensively on the posterior wall and roof region (89.5–100% of patients; median 1.1–2.7 cm2 per region). Fluoroscopy-guided PFA-PVI frequently results in insufficient isolation areas in the left anterior antral PV segments and enlarged LA isolation areas on the posterior wall/roof, which both may be extensive. To optimize the procedure, full integration of PFA catheter visualization into three-dimensional-mapping systems is needed.
4 January 2023 in EP Europace
Aims: Transseptal puncture (TP) for left-sided catheter ablation procedures is routinely performed under fluoroscopic or echocardiographic guidance [transoesophageal echocardiography (TEE) or intracardiac echocardiography (ICE)], although three-dimensional (3D) mapping systems are readily available in most electrophysiology laboratories. Here, we sought to assess the feasibility and safety of a right atrial (RA) 3D map–guided TP.Methods and results: In 104 patients, 3D RA mapping was performed to identify the fossa ovalis (FO) using the protrusion technique. The radiofrequency transseptal needle was visualized and navigated to the desired potential FO-TP site. Thereafter, the interventionalist was unblinded to TEE and the potential FO-TP site was reassessed regarding its convenience and safety. After TP, the exact TP site was documented using a 17-segment-FO model. Reliable identification of the FO was feasible in 102 patients (98%). In these, 114 3D map–guided TP attempts were performed, of which 96 (84%) patients demonstrated a good position and 18 (16%) an adequate position after TEE unblinding. An out-of-FO or dangerous position did not occur. A successful 3D map–guided TP was performed in 110 attempts (97%). Four attempts (3%) with adequate positions were aborted in order to seek a more convenient TP site. The median time from RA mapping until the end of the TP process was 13 (12–17) min. No TP-related complications occurred. Ninety-eight TP sites (85.1%) were in the central portion or in the inner loop of the FO.Conclusion: A 3D map–guided TP is feasible and safe. It may assist to decrease radiation exposure and the need for TEE/ICE during left-sided catheter ablation procedures.
19 October 2022 in Journal of Cardiovascular Electrophysiology
Introduction: Phrenic nerve (PN) injury is a rare but severe complication of radiofrequency (RF) pulmonary vein isolation (PVI). The objective of this study was to characterize the typical intracardiac course of the PN with a three‐dimensional electroanatomic mapping system, to quantify the need for modification of the ablation trajectory to avoid delivering an ablation lesion on sites with PN capture, and to identify very circumscribed areas of common PNC on the routine ablation trajectory of a RF‐PVI, allowing fast and effective PN screening for everyday usage.Methods: We enrolled 137 consecutive patients (63 ± 9 years, 64% men) undergoing PVI. A detailed high output (20 mA) pace‐mapping protocol was performed in the right (RA) and left atrium (LA) and adjacent vasculature.Results: The right PN was most commonly captured in the superior vena cava at a lateral (50%) or posterolateral (23%) position before descending along the RA either straight (29%) or with a posterolateral bend (20%). In the LA, beginning deep within the right superior pulmonary vein (RSPV), the right PN is most frequently detectable anterolateral (31%), then descends to the lateral proximal RSPV (23%), and further towards the lateral antral region (15%) onto the medial LA wall (12%). To avoid delivering an ablation lesion on sites with PN capture, modification of ablation trajectory was necessary in 23% of cases, most commonly in the lateral RSPV antrum (81%). No PN injury occurred.Conclusion: PN mapping frequently reveals the close proximity of the PN to the ablation trajectory during PVI, particularly in the lateral RSPV antrum. Routine PN pacing should be considered during RF PVI procedures.
29 December 2022 in European Heart Journal Open
Aims: With recurrence rates up to 50% after pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF), predictive tools to improve patient selection are needed. Patient selection based on left atrial late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been proposed previously (UTAH-classification). However, this approach has not been widely established, in part owed to the lack of standardization of the LGE quantification method. We have recently established a standardized LGE-CMR method enabling reproducible LGE-quantification. Here, the ability of this method to predict outcome after PVI was evaluated.Methods and results: This dual-centre study (n = 219) consists of a prospective derivation cohort (n = 37, all persistent AF) and an external validation cohort (n = 182; 66 persistent, 116 paroxysmal AF). All patients received an LGE-CMR prior to first-time PVI-only ablation. LGE was quantified based on the signal-intensity-ratio relative to the blood pool, applying a uniform LGE-defining threshold of >1.2. In patients with persistent AF in the derivation cohort, left atrial LGE-extent above a cut-off value of 12% was found to best predict relevant low-voltage substrate (≥2 cm two with <0.5 mV during sinus rhythm) and arrhythmia-free survival 12 months post-PVI. When applied to the external validation cohort, this cut-off value was also predictive of arrhythmia-free survival for both, the total cohort and the subgroup with persistent AF (LGE < 12%: 80% and 76%; LGE > 12%: 55% and 44%; P = 0.007 and P = 0.029, respectively).Conclusion: This dual-centre study established and validated a standardized, reproducible LGE-CMR method discriminating PVI responders from non-responders, which may improve choice of therapeutic approach or ablation strategy for patients with persistent AF.