Jiawei Mei

Jiawei Mei

Auto-generated profile, based on publicly available information

Jiawei Mei

Department of Orthopedics, Centre for Leading Medicine and Advanced Technologies of IHM, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine University of Science and Technology of China Hefei China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
LKLingtong Kong
Lingtong Kong
JMJiawei Mei
Jiawei Mei
WGWufei Ge
Wufei Ge
XJXiansheng Jin
Xiansheng Jin
XCXiaoxuan Chen
Xiaoxuan Chen
CZChen Zhu
Chen Zhu
Background. Bone cement spacers are widely used in two‐stage revision surgeries for periprosthetic joint infection (PJI) after total knee arthroplasty. Current spacer design results in insufficient release of drugs; therefore, current spacers have low efficacy. In this study, we explored a set of alternative articular spacer using 3D printing technology. This novel spacer will increase effectiveness of revision surgery for PJI. Methods. The spacer was designed using CAD software and constructed on site using 3D‐printed silicone mold during debridement surgery. We carried out a retrospective study among patients undergoing treatment using traditional static and new articular spacers. Infection control rate, bone loss, difficulty of revision surgery, knee joint range of motion, function evaluation, and subjective satisfaction of the patients in the two groups were compared. Results. Forty‐two patients undergoing knee revision surgery between Jan 2014 and Nov 2019 were included in this study. Twenty‐two patients were treated with static antibiotic cement spacers, whereas the other twenty patients were with treated with 3D printing‐assisted antibiotic loaded articulating spacers. Patients in the articular group showed significantly lower bone loss on the femur site and tibial site compared with patients in the static group. In addition, patients in the articular group showed significantly less operation time, intraoperative blood loss, and improved knee function and patient overall satisfaction compared with patients in the static group. Conclusions. The 3D printing‐assisted articular spacer provides satisfactory range of motion during the interim period, prevents bone loss, facilitates second‐stage reimplantation and postoperative rehabilitation, and results in low reinfection and complication rates.

18 June 2024 in Orthopaedic Surgery
Verified
Journal Article
Open access
XSXianyue Shen
Xianyue Shen
RZRongwei Zhang
Rongwei Zhang
JMJiawei Mei
Jiawei Mei
XZXianzuo Zhang
Xianzuo Zhang
WHWei Huang
Wei Huang
CZChen Zhu
Chen Zhu
Objective: Total hip arthroplasty (THA) combined with proximal femoral reconstruction is a novel osteotomy technique developed to address severe hip deformities. There is a paucity of robust clinical and radiological evidence regarding the outcomes of this novel osteotomy technique. This study aimed to evaluate the clinical and radiological outcomes of THA combined with proximal femoral reconstruction during the early follow‐up.Methods: This is a retrospective case series of 63 hips who underwent THA combined with proximal femoral reconstruction at a single institution between January 2020 and July 2023. The mean age of patients was 39.6 ± 12.6 years. The mean follow‐up was 25.6 ± 3.8 months. Surgical characteristics and perioperative variables were evaluated to assess the efficacy of this technique. Harris hip score (HHS) was utilized to evaluate hip function. Leg length discrepancy (LLD) was evaluated in X‐ray. The incidence of major adverse events including deep vein thrombosis (DVT), osteolysis, nonunion of the osteotomy, intraoperative femoral fracture, and infection was also evaluated. Paired‐samples t‐test was used to compare preoperative and postoperative HHS and LLD.Results: The mean operative time was 125.1 min. The mean size of the acetabular components used was 45.2 mm, and the stem size was 7.5. The primary friction interface was ceramic‐on‐ceramic, accounting for 92.1% of cases. The average length of hospital stay was 8.5 days. The mean cost of treatment was 46,296.0 Yuan. There was a significant improvement in postoperative HHS (p < 0.001) and LLD (p < 0.001) compared to preoperative values. The incidence of deep venous thrombosis was 4.8%; osteolysis rates for the cup and stem were 4.8% and 6.4%, respectively. The non‐union and dislocation rates were 1.6% and 3.2%, respectively. There was no incidence of postoperative infection.Conclusion: The novel osteotomy surgical procedure yields reliable and impressive clinical and radiological outcomes, with minimal complications. We advocate for its use in complex primary THA cases involving severe proximal femoral deformities.

1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
LKLingtong Kong
Lingtong Kong
JMJiawei Mei
Jiawei Mei
WGWufei Ge
Wufei Ge
XJXiansheng Jin
Xiansheng Jin
XCXiaoxuan Chen
Xiaoxuan Chen
CZChen Zhu
Chen Zhu
In the article titled “Application of 3D Printing-Assisted Articulating Spacer in Two-Stage Revision Surgery for Periprosthetic Infection after Total Knee Arthroplasty: A Retrospective Observational Study” [1], some of the authors were linked to the incorrect affiliations in the affiliation list. The correct author affiliations are now corrected in the author information above.