Robert W. Johnson

Robert W. Johnson

Auto-generated profile, based on publicly available information

Robert W. Johnson

Discovery Platform Technologies, AbbVie Inc., North Chicago, Illinois 60064, United States

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

10 March 2014 in Analytical Chemistry
Verified
Journal Article
Open access
ENEslam Nouri-Nigjeh
Eslam Nouri-Nigjeh
MZMing Zhang
Ming Zhang
TJTao Ji
Tao Ji
HYHaoying Yu
Haoying Yu
BABo An
Bo An
Jun  QuJun Qu
Jun Qu
LC–MS provides a promising alternative to ligand-binding assays for quantification of therapeutic proteins and biomarkers. As LC–MS methodology is based on the analysis of proteolytic peptides, calibration approaches utilizing various calibrators and internal standards (I.S.) have been developed. A comprehensive assessment of the accuracy and reliability of these approaches is essential but has yet been reported. Here we performed a well-controlled and systematic comparative study using quantification of monoclonal-antibody in plasma as the model system. Method development utilized a high-throughput orthogonal-array-optimization, and two sensitive and stable signature-peptides (SP) from different domains were selected based on extensive evaluations in plasma matrix. With the purities of all protein/peptide standards corrected by quantitative amino acid analysis (AAA), five calibration approaches using stable-isotope-labeled (SIL) I.S. were thoroughly compared, including those at peptide, extended-peptide, and protein levels and two “hybrid” approaches (i.e., protein calibrator with SIL-peptide or SIL-extended-peptide I.S.). These approaches were further evaluated in parallel for a 15 time point, preclinical pharmacokinetic study. All methods showed good precision (CV% < 20%). When examined with protein-spiked plasma QC, peptide-level calibration exhibited severe negative biases (−23 to −62%), highly discordant results between the two SP (deviations of 38–56%), and misleading pharmacokinetics assessments. Extended-peptide calibration showed significant improvements but still with unacceptable accuracy. Conversely, protein-level and the two hybrid calibrations achieved good quantitative accuracy (error < 10%), concordant results by two SP (deviations < 15%), and correct pharmacokinetic parameters. Hybrid approaches were found to provide a cost-effective means for accurate quantification without the costly SIL-protein. Other key findings include (i) using two SP provides a versatile gauge for method reliability; (ii) evaluation of peptide stability in the matrix before SP selection is critical; and (iii) using AAA to verify purities of protein/peptide calibrators ensures accurate quantitation. These results address fundamental calibration issues that have not been adequately investigated in published studies and will provide valuable guidelines for the “fit for purpose” development of accurate LC–MS assays for therapeutic proteins and biomarkers in biological matrices.

22 December 2009 in Journal of Plasma Physics
Verified
Journal Article
Open access
PDF file
RJRobert W. Johnson
Robert W. Johnson
Following the arguments presented by Mansuripur [Opt. Express, vol.16, 2008, pp. 14821–14835], we suggest a form for the macroscopic electromagnetic stress tensor appropriate for ionized media. The generalized Lorentz force includes the effects of polarization forces as well as those on the free charge and current densities. The resulting tensor is written in terms of the fieldsD,B,E, andH. Its expression for a fully ionized medium subject to an external electromagnetic field is discussed, as are the plasma conservation equations. An apparatus is suggested for its experimental discrimination.

11 January 2019 in ACS Medicinal Chemistry Letters
Verified
Journal Article
Closed access
RJRobert W. Johnson
Robert W. Johnson
NTNari Talaty
Nari Talaty

1 January 2012 in International Journal of Wavelets, Multiresolution and Information Processing
Verified
Journal Article
Open access
RJRobert W. Johnson
Robert W. Johnson
The forward and inverse wavelet transform using the continuous Morlet basis may be symmetrized by using an appropriate normalization factor. The loss of response due to wavelet truncation is addressed through a renormalization of the wavelet based on power. The spectral density has physical units which may be related to the squared amplitude of the signal, as do its margins the mean wavelet power and the integrated instant power, giving a quantitative estimate of the power density with temporal resolution. Deconvolution with the wavelet response matrix reduces the spectral leakage and produces an enhanced wavelet spectrum providing maximum resolution of the harmonic content of a signal. Applications to data analysis are discussed.

30 May 2023 in ACS Medicinal Chemistry Letters
Verified
Journal Article
Closed access
NTNari Talaty
Nari Talaty
RJRobert W. Johnson
Robert W. Johnson
JSJames Sawicki
James Sawicki
ONOmprakash Nacham
Omprakash Nacham
SDStevan W. Djuric
Stevan W. Djuric