Weiliang Du

Weiliang Du

Auto-generated profile, based on publicly available information

Weiliang Du

Department of Radiology, University of Chicago, Illinois 60637, USA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2003 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
WDWeiliang Du
Weiliang Du
YDYiping P. Du
Yiping P. Du
XFXiaobing Fan
Xiaobing Fan
MZMarta A. Zamora
Marta A. Zamora
GKGregory S. Karczmar
Gregory S. Karczmar
Echo-planar spectroscopic imaging (EPSI) can be used for fast spectroscopic imaging of water and fat resonances at high resolution to improve structural and functional imaging. Because of the use of oscillating gradients during the free induction decay (FID), spectra obtained with EPSI are often degraded by Nyquist ghost artifacts arising from the inconsistency between the odd and even echoes. The presence of the spectral ghost lines causes errors in the evaluation of the true spectral lines, and this degrades images derived from high-resolution EPSI data. A technique is described for reducing the spectral ghost artifacts in EPSI of water and fat resonances, using echo shift and zero-order phase corrections. These corrections are applied during the data postprocessing. This technique is demonstrated with EPSI data acquired from human brains and breasts at 1.5 Tesla and from a water phantom at 4.7 Tesla. Experimental results indicate that the present approach significantly reduces the intensities of spectral ghosts. This technique is most useful in conjunction with high-resolution EPSI of water and fat resonances, but is less applicable to EPSI of metabolites due to the complexity of the spectra. Magn Reson Med 49:1113–1120, 2003.

19 September 2003 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
Milica MedvedMilica Medved
Milica Medved
WDWeiliang Du
Weiliang Du
MZMarta A. Zamora
Marta A. Zamora
XFXiaobing Fan
Xiaobing Fan
OOOlufunmilayo I. Olopade
Olufunmilayo I. Olopade
GKGregory Stanislaus Karczmar
Gregory Stanislaus Karczmar
Purpose To evaluate the effect of varying spectral resolution on image quality of high spectral and spatial resolution (HiSS) images. Materials and Methods Eight women with suspicious breast lesions and six healthy volunteers were scanned using echo-planar spectroscopic imaging (EPSI) at 1.5 Tesla with 0.75- to 1-mm in-plane resolution and 2.3- to 2.6-Hz spectral resolution. Time domain data were truncated to obtain proton spectra in each voxel with varying (2.6–83.3 Hz) resolution. Images with intensity proportional to water signal peak heights were synthesized. Changes in water signal line shape following contrast injection were analyzed. Results Fat suppression is optimized at ∼10-Hz spectral resolution and is significantly improved by removal of wings of the fat resonance. This was accomplished by subtracting a Lorentzian fit to the fat resonance from the proton spectrum. The water resonance is often inhomogeneously broadened, and very high spectral resolution is necessary to resolve individual components. High spectral resolution is required for optimal contrast in anatomic features with very high T2* (e.g., within a lesion) and for detection of often subtle effects of contrast agents on water signal line shape. Conclusion Despite a trade-off between the spectral resolution and signal-to-noise ratio, it is beneficial to acquire data at the highest spectral resolution currently attainable at 1.5 Tesla. J. Magn. Reson. Imaging 2003;18:442–448.

28 June 2004 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
Milica MedvedMilica Medved
Milica Medved
GNGillian M. Newstead
Gillian M. Newstead
XFXiaobing Fan
Xiaobing Fan
WDWeiliang Du
Weiliang Du
YDYiping P. Du
Yiping P. Du
GKGregory S. Karczmar
Gregory S. Karczmar
High spectral and spatial resolution (HiSS) MR data were acquired at 1.5 T using echo-planar spectroscopic imaging from patients with suspicious breast lesions. The water resonances in small voxels are inhomogenously broadened and often have distinct components. Images were calculated with intensity proportional to the Fourier components of the water resonance in each voxel at different offsets from the peak frequency. The results demonstrate that in breast the off-peak Fourier component images of water are qualitatively different from those derived from the peak height of the water resonance. These differences most likely reflect underlying anatomy or physiology. In conventional images, the superposition of the various Fourier components of the water signal may cause loss of detail. The synthesis of water Fourier component images from high spectral and spatial resolution data may provide a new form of contrast, and increase sensitivity to subvoxel physiology and anatomy. Magn Reson Med 52:193–196, 2004.

24 July 2002 in Medical Physics
Verified
Journal Article
Closed access
WDWeiliang Du
Weiliang Du
GKGregory S. Karczmar
Gregory S. Karczmar
XPXiaochuan Pan
Xiaochuan Pan