Noor Diyana Osman

Noor Diyana Osman

Auto-generated profile, based on publicly available information

Noor Diyana Osman

Universiti Sains Malaysia

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

19 February 2019 in Journal of Radiotherapy in Practice
Verified
Journal Article
Closed access
PDF file
JJJayapramila Jayamani
Jayapramila Jayamani
NONoor Diyana Osman
Noor Diyana Osman
ATAbdul Aziz Tajuddin
Abdul Aziz Tajuddin
ZSZaker Salehi
Zaker Salehi
MAMohd Hanafi Ali
Mohd Hanafi Ali
MAMohd Zahri Abdul Aziz
Mohd Zahri Abdul Aziz
Aim: The main aim was to examine the effect of bit depth on computed tomography (CT) number for high-density materials. Analysis of the CT number for high-density materials using 16-bit scanners will extend the CT scale that currently exists for 12-bit scanners and thus will be beneficial for use in CT–electron density (ED) curve in radiotherapy treatment planning system (TPS). Implementation of this extended CT scale will compensate for tissue heterogeneity during CT–ED conversion in treatment planning.Materials and methods: An in-house built phantom with 10 different metal samples was scanned using 80, 100 and 120 kVp in two different CT scanners. A region of interest was set at the centre of the material and the mean CT numbers together with data deviation were determined. Dosimetry calculation was performed by applying a direct anterior beam on 12-bit, 12-bit extended and 16-bit.Results: High-density materials (>4·34 g cm−3) in 16-bit depth provide disparities up to 44% compared to Siemens’ 12-bit extended. Influence of tube voltage showed a significant difference (p<0·05) in both bit depth and CT number of the gold and amalgam saturated in 16-bit depth. A 120 kVp energy illustrated a low variation on CT number for different scanners, but dosimetry calculation showed significant disparities at the metal interface in 12-bit, 12-bit extended and 16-bit.Findings: High-density materials require 16-bit scanners to obtain CT number to be implemented in treatment planning in radiotherapy. This also suggests that proper tube voltage together with correct CT–ED resulted in accurate TPS algorithm calculation.

1 June 2020 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
MAMuhammad Kabir Abdulkadir
Muhammad Kabir Abdulkadir
NRNur Atikah Yusra Mat Rahim
Nur Atikah Yusra Mat Rahim
NMNur Syazwani Mazlan
Nur Syazwani Mazlan
NDNorfataha Mohd Daud
Norfataha Mohd Daud
ISIbrahim Lutfi Shuaib
Ibrahim Lutfi Shuaib
NONoor Diyana Osman
Noor Diyana Osman

1 January 2020 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
MRMohd Amirul Azrie Mohd Roslee
Mohd Amirul Azrie Mohd Roslee
ISIbrahim Lutfi Shuaib
Ibrahim Lutfi Shuaib
ANAhmad Fakharuddin Mohd Napi
Ahmad Fakharuddin Mohd Napi
MRMohd Amir Syahmi Mat Razali
Mohd Amir Syahmi Mat Razali
NONoor Diyana Osman
Noor Diyana Osman

30 December 2019 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
MRMohd Amir Syahmi Mat Razali
Mohd Amir Syahmi Mat Razali
MAMuhamad Zabidi Ahmad
Muhamad Zabidi Ahmad
ISIbrahim Lutfi Shuaib
Ibrahim Lutfi Shuaib
NONoor Diyana Osman
Noor Diyana Osman
The aim of this study was to propose local diagnostic reference levels (LDRLs) for the most common computed tomography (CT) examinations (including contrast and non-contrast scan phase) performed at Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia (USM), Malaysia. A retrospective CT dose survey of 1488 subjects from January 2015 until December 2018 was performed at AMDI USM, Malaysia. The proposed DRLs were established at 50th and 75th percentile of dose distribution for all dose metrics (CT dose index [CTDI]; CTDIvol, CTDIw and dose–length product). The proposed LDRLs were compared with national DRLs and other established DRLs. The 10 most common CT examinations at AMDI were thorax–abdomen–pelvis (TAP) CT (46%), followed by pelvis CT (17%), abdomen–pelvis CT (10%), brain/head CT (9%) and other CT protocols. The local DRLs were established using the third quartile values of dose distribution and were categorized based on CT region protocols. Most of the proposed DRLs were exceeded the national DRLs (63%) and other international DRLs (67%). From the dose auditing, almost half of the recent dose data (for year 2018) exceeded the proposed local DRLs and the unusual dose were observed in TAP, brain/head and pelvis CT examinations. The unusual higher dose could be due to higher mAs settings, higher number of scan phase for contrast study and higher pitch factor. The local DRLs should be established for dose optimization and reduction of the occurrence of excessive radiation exposure to the patients. The establishment of the Ads and LDRLs should also consider all the factors that affect the variation in DRLs such as CT technology, scanning protocols and population characteristics. The local dose distribution should always be revised for improvement of the current local practice.

5 February 2021 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
MAMuhammad Kabir Abdulkadir
Muhammad Kabir Abdulkadir
IIIliyasu Yusuf Izge
Iliyasu Yusuf Izge
GYGarba Haruna Yunusa
Garba Haruna Yunusa
AMAbacha Mohammed
Abacha Mohammed
NONoor Diyana Osman
Noor Diyana Osman