5 September 2023 in IEEE Transactions on Power Systems
In a multi-voltage-source-converter (multi-VSC) system, there may be a scenario where some VSCs lose synchronization stability and others keep stable under grid faults. To describe and analyze the transient behavior of the system under such a scenario, accurate equivalent models are indispensable. In this article, a coherency-based equivalent aggregated modeling method of multi-VSC systems is developed for transient stability analysis. By investigating the factors that reflect the dynamic characteristics of VSCs, the pre-fault and post-fault q -axis voltage drops on collector impedance of each VSC are selected as the coherency identification indicators, and a coherency criterion based on these indicators is proposed. Then, by assessing the transient synchronization stability of multiple VSCs, a criterion based on electrical distances is provided to ensure that VSCs with different stability will not be divided into a coherent group. Combining these two criteria, VSCs can be divided into different coherent groups and aggregated as several equivalent VSCs. Thus, the equivalent model of the multi-VSC system can be obtained. The proposed model is verified by simulations of a multi-VSC system connected to the IEEE 39-bus power grid. Compared with the existing equivalent model, the proposed model shows advantages in precisely reflecting the power dynamics of the multi-VSC system where VSCs present different transient stability under faults. It provides an effective tool for behavior prediction and transient synchronization stability analysis of multiple VSCs.
25 February 2025 in IEEE Transactions on Power Systems
Lyapunov's direct method plays an important role as a very commonly used analytical tool in studies on transient synchronization stability (TSS) of grid-following converters. To bridge the gap that energy-type Lyapunov function (LF) is only effective in the positive damping area and thus too conservative, a novel LF whose domain of definition includes part of negative damping area is proposed for TSS analysis of grid-following converters. Its corresponding TSS criterion and estimated region of attraction (ROA) exhibit significantly reduced yet still guaranteed conservativeness, endowing them with more practical value and higher efficiency in analytical TSS assessment works.
4 March 2025 in IEEE Transactions on Sustainable Energy
The operation mode of grid-forming voltage source converters (GFM-VSCs) may switch between voltage source mode (VSM) and current source mode (CSM) under some situations such as grid faults, owing to the current limitation control. During the mode-switching process, there is state transfer from the final state of the last mode to the initial state of the next mode, which impacts the transient synchronization stability (TSS) of GFM-VSCs. This paper primarily focuses on analyzing and improving the TSS of GFM-VSCs by considering the effect of state transfer. A novel transient instability mechanism is revealed through the existence analysis of equilibrium points. It clarifies that the state transfer may cause the operating trajectory during faults to bypass the stable equilibrium point in CSM before diverging to the next cycle, thereby resulting in transient synchronization instability. Besides, to further analyze the TSS of mode-switched VSCs considering the dynamics during faults, multiple Lyapunov functions are adopted to derive the TSS criteria and boundaries. It has been identified that lowering the minimum critical current and adjusting the saturated current phase in accordance with virtual power angle (VPA) dynamics can enhance the TSS. Therefore, a VPA feedback-based current limiting strategy is proposed to safeguard GFM-VSCs against overcurrent and ensure the TSS. The validity of the new transient instability mechanism and the efficacy of the proposed strategy are confirmed through simulations of a GFM-VSC connected to an IEEE 39-bus power grid and hardware-in-the-loop experiments.
22 May 2024 in IEEE Transactions on Industry Applications
In recent years, grid-connected power electronic converters have had a continuously increasing influence on dynamics of bulk power systems. Consequently, modelling of power electronic converters has become critical to modern power system stability studies. However, few existing studies can systematically model switching control characteristics or handle discontinuous state variables of power electronic converters. To address these limitations, this article proposes a general four-step analytical switching modelling method of grid-connected converters, which involves formulating holonomic differentialalgebraic equations of the converter including all switching actions, transforming all state-dependent switching conditions into time-dependent ones, deriving differential equations of the system for all time periods, and analyzing the continuity of each state variable at all switching moments. An example model is established and then evaluated through detailed simulations to verify the effectiveness of the proposed modelling method. The revealed switching-induced transient instability mechanism and corresponding stability enhancement method based on the example model demonstrate the practicality of the proposed method and emphasize the importance of considering switching characteristics in analytical modelling of power electronic converters.