18 July 2014 in Advanced Robotics
20 August 2017 in Journal of Robotics and Mechatronics
This paper presents an evaluation of the maneuverability of impedance-controlled robot motion during a human-robot cooperative positioning task. The objectives of this study are to reveal the results of a quantitative evaluation of the maneuverability of robot motion and to investigate the relationship between the results of the quantitative evaluation and an operator’s higher-order brain activity. Control strategies for the robot that are adequate for human-robot interaction have not yet been explicitly determined because of the difficulty in evaluating the maneuverability of robot motion. First, we analyzed the time normalized position and force/torque trajectories to reveal the characteristics of human motion and performed subjective evaluations for three types of impedance-controlled robot motion, which were controlled using the following strategies: (i) ordinary impedance control, (ii) impedance control with virtual Coulomb friction involved in the robot motion, and (iii) impedance control with a trajectory guidance force. Second, to confirm the analysis results based on the observed trajectories, we investigated differences in the operator’s higher-order brain activity when using the different control strategies by using a functional near-infrared spectroscopy system. The experimental results confirmed the relationship between the analysis results of the control strategies, the motion of the operator, and higher-order brain activity. Consequently, the investigation conducted in this study is effective for evaluating the maneuverability of robot motion during a human-robot cooperative task.
1 January 2016 in Transactions of the JSME (in Japanese)
The objective of this study was to develop a motion analysis system to evaluate relations between the activation of the lower limb muscles, the pedal force and the movement of the lower limb during the pedaling motion. To confirm the effectiveness of the proposed analysis system, we analyzed the pedaling motion of nine cyclists to identify their pedaling skill. In the experiments, cyclists were instructed to perform their pedaling technique at two pedaling rates (80-90 rpm and 110-120 rpm). Surface electromyography (EMG) signals was recorded from tensor of latae (TFL), rectus femoris (RF), hamstrings (HAM) and gastrocnemius (GAS), and pedal force was measured by a power meter (Pioneer Corporation). Furthermore, the lower limb motion during the pedaling was measured using a 3D motion capture system to investigate the relations among measured data as mentioned above. The experimental results show that the proposed analysis system reveals the pedaling skill of cyclists and the relations between the EMG data, the pedal force and the movement during the pedaling motion. In this paper, firstly, the activation section of the lower limb muscles during the pedaling was determined quantitatively. Secondly, Tukey-Kramer test was conducted to determine whether there are significant differences (p < 0.05) between the pedaling effectiveness of the three groups (elite group, amateur group and beginner group). Finally, the pedaling skill of the cyclists was revealed based on the analysis results of the measurement experiments.
1 February 2022 in Journal of Robotics and Mechatronics
In this paper, we proposed a distributed controlled gait rehabilitation and locomotion support system through human-robot cooperative control, and combination of two cane-type walking support robots (left and right) and one wheelchair robot to support the walking and locomotion of a person in need of walking assistance. The proposed system can realize five types of motion support from gait training to daily motion support, using three types of motion support modes with a distributed robot control system comprising up to three robots to support the user's independence for walking and moving. The cane-type walking support robot moved in response to the manipulation force applied to the robot by the user, and can realize walking/movement support in all directions through the omnidirectional traveling part. In addition, the height of the robot can be adjusted according to the user's physique, and the motion characteristics can be set according to the user's walking ability. The wheelchair robot has a seat that can be raised, lowered, and tilted to provide standing assistance for the user and mobility support as an electric wheelchair. In this study, we developed a prototype of the proposed system and demonstrated its feasibility for five types of assistive actions in experiments with healthy subjects.
28 March 2023 in IEEE Access
Human–machine interface (HMI) devices have become multifunctional and complicated to operate, requiring better usability. Nevertheless, response latency (time lag between operation input and display output) negatively impacts device usability because it is stressful and reduces the operator’s sense of agency (SoA)—the sense that the operator is the one who is causing or generating an action. Stress and SoA information can be obtained by measuring physiological indicators, such as brain activity. This study was designed to investigate the effects of response latency on the operator’s brain activity state through near-infrared spectroscopy, which measures the brain activity state based on changes in the concentration of oxygenated hemoglobin (ΔOxy–Hb). In this study, 15 subjects performed a target-tracking task in which they rotated an HMI commander used as an in-vehicle device to manipulate LED markers on a display. The temporal response latency (0, 50, 100, and 150 ms) between manipulating the commander and the display response was introduced, and the subject’s brain activity, subjective evaluation, and performance efficiency were measured. The results revealed that brain activity differed depending on whether the latency was recognized rather than the latency length, and that ΔOxy–Hb at the anterior prefrontal cortex of those who recognized the latency increased significantly, whereas that of those who did not recognize the latency did not increase. Specifically, latency perception activates the prefrontal cortex due to stress and the inability to prepare normally for the next action, and not recognizing latency inactivates the premotor cortex.
16 August 2024 in IEEE Access
The operation of display-equipped devices, such as smartphones and car navigation systems, is based on sensory input and visual information provided by the display. Therefore, it is necessary to clarify the effect of the system response time between the input by the user and the response displayed by the device during operation. The purpose of this study was to clarify the effects of the length of and variance in the system response time on brain activity and on the users’ experience when operating a device. The experiment entailed a task in which participants followed a target by rotating a human-machine interface (HMI) controller. The experimental conditions consisted of four levels of constant delay from 0 ms to 120 ms and a randomized variable delay. Near-infrared spectroscopy, which measures brain activity based on changes in oxygenated hemoglobin concentration, was used to assess brain activity during the experiment. Participants’ brain activity during the trials suggested that the SoA was impaired when the delay was not constant. NASA-TLX was also used to investigate participants’ mental workload, the delay discrimination rate, and participants’ work efficiency in each condition. The results confirmed that an increase in system response time increased mental workload and decreased work efficiency. In addition, the delay discrimination rate varied among individuals; thus, differences in activation were confirmed in the prefrontal cortex and supplementary motor cortex in the group of subjects with a high discrimination rate and the group of subjects with a low discrimination rate.