EPSRC Continuous Manufacturing and Crystallisation Future Research Hub c/o Strathclyde Institute of Pharmacy and Biomedical Sciences, Technology Innovation Centre, University of Strathclyde, Glasgow, UK
Auto-generated profile, based on publicly available information
Deborah Bowering
EPSRC Continuous Manufacturing and Crystallisation Future Research Hub c/o Strathclyde Institute of Pharmacy and Biomedical Sciences, Technology Innovation Centre, University of Strathclyde, Glasgow, UK
Stimuli-responsive nanocarriers have attracted increased attention as materials that can facilitate drug and gene delivery in cancer therapy. The present study reports the development of redox-sensitive dendrimersomes comprising disulfide-linked cholesterol-bearing PEGylated dendrimers, which can be used as drug and gene delivery systems. Two disulfide-linked cholesterol-bearing PEGylated generation 3 diaminobutyric polypropylenimine dendrimers have been successfully synthesized via an in situ two-step reaction. They were able to spontaneously self-assemble into stable, cationic, nanosized vesicles (or dendrimersomes) with lower critical aggregation concentration values for high-cholesterol-bearing vesicles. These dendrimersomes were able to entrap both hydrophilic and hydrophobic dyes, and they also showed a redox-responsive sustained release of the entrapped guests in the presence of a glutathione concentration similar to that of a cytosolic reducing environment. The high-cholesterol-bearing dendrimersomes were found to have a higher melting enthalpy, increased adsorption tendency on mica surface, entrapping ability for a larger amount of hydrophobic drugs, and increased resistance to redox-responsive environments in comparison with their low-cholesterol counterpart. In addition, both dendrimersomes were able to condense more than 85% of the DNA at all the tested ratios for the low-cholesterol vesicles, and at dendrimer : DNA weight ratios of 1 : 1 and higher for the high-cholesterol vesicles. These vesicles resulted in an enhanced cellular uptake of DNA, by up to 15-fold when compared with naked DNA with low-cholesterol vesicles. As a result, they increased the gene transfection on the PC-3 prostate cancer cell line, with the highest transfection being obtained with low-cholesterol vesicle complexes at a dendrimer : DNA weight ratio of 5 : 1 and high-cholesterol vesicle complexes at a dendrimer : DNA weight ratio of 10 : 1. These transfection levels were about 5-fold higher than those observed when treated with naked DNA. These cholesterol-bearing PEGylated dendrimer-based vesicles are, therefore, promising as redox-sensitive drugs and gene delivery systems for potential applications in combination cancer therapies.
1 January 2019 in International Journal of Pharmaceutics
Wet milling coupled with crystallisation has considerable potential to deliver enhanced control over particle attributes. The effect of process conditions and wet mill configuration on particle size, shape and surface energy has been investigated on acetaminophen using a seeded cooling crystallisation coupled with a wet mill unit generating size controlled acetaminophen crystals through an interchangeable rotor-tooth configuration. The integrated wet milling crystallisation platform incorporates inline focused beam reflectance measurement (FBRM) and particle vision measurement (PVM) for in-depth understanding of particle behaviour under high-shear conditions. We used a recently developed computational tool for converting chord length distribution (CLD) from FBRM to particle size distribution (PSD) to obtain quantitative insight into the effect of the competing mechanisms of size reduction and growth in a wet milling seeded crystallisation process for acetaminophen. The novelty of our wet milling crystallisation approach is in delivery of consistent surface energies across a range of particle sizes. This highlights the potential to engineer desirable particle attributes through a carefully designed, highly intensified crystallisation process.
While downhole chemical squeeze treatments are common practice for deploying scale inhibitors to protect wellbores and downhole production tubulars from inorganic deposits, their adoption for corrosion inhibitor treatments (CISQ) is much less commonplace. Historically they have often not been considered an option due to either anticipated poor lifetimes or the risk of formation damage in the form of emulsion blocks, wettability changes or relative permeability modification. However, in a number of carbonate reservoirs producing from different regions, corrosion inhibitor squeeze treatments have been shown to provide corrosion protection for downhole production tubulars when no alternative downhole chemical deployment technique is available. This paper will present a technical review of the potential benefits of CISQ treatments. Different inhibitor retention/release mechanisms in sandstone and fractured carbonate reservoirs will be discussed, including classic adsorption/desorption and chemical imbibition/diffusion, as will the impact of these mechanisms and oil/water partitioning behaviour on squeeze lifetimes. Another factor limiting adoption of CISQ treatments is the misconception that residual assay techniques may be inadequate, and we demonstrate that this is not necessarily the case. In addition to providing a mechanistic interpretation of the available retention and release mechanisms, the results of laboratory core flood studies will illustrate the different retention mechanisms and offer the potential to achieve considerably different lifetimes with different types of corrosion inhibitors. Field examples will also be cited in support of this. In these cases, the accuracy of the measured residual corrosion inhibitor return concentrations were confirmed by conventional electrochemical corrosion inhibitor performance measurements.
The use of inflow-control valves (ICVs) and inflow-control devices (ICDs) to improve production rates in horizontal wells has become increasingly common in recent years. These devices have small apertures resulting in high, local high flow rates which results in regimes of very high shear and turbulence, potentially resulting in materials failure due to accelerated corrosion rates, erosion and potentially erosion-corrosion. To meet the challenge of testing accelerated corrosion rates, various laboratory methods have been developed to study the effects of increasing shear on corrosion. Common test methods such as rotating-cylinder electrode (RCE) tests can provide useful data at moderate shear stresses (up to 100 Pa) and ambient pressures, while rotating-cage autoclave tests (RCA) and rotating-cylinder electrochemical autoclave (RCEA) tests allow moderate shear tests to be conducted at elevated temperatures and pressures. However, achieving the very high wall shear stresses seen with certain oilfield jewellery, such as ICVs and ICDs, is significantly more challenging. In contrast, jet impingement (JI) methods have enabled materials testing at up to 10,000 Pa, and by coupling these with the ability to conduct these tests under increasingly higher pressures and temperatures, very-high-shear systems can be tested under conditions closely matched to those in the field. The approaches developed in our laboratories, which use both weight loss and electrochemical corrosion measurements, have also proved to be robust even in extremely corrosive environments, such as in the presence of stimulation acids (both uninhibited and inhibited) and over extended exposure times (> 7 days). These jet-impingement test methods have enabled enhanced understanding of the susceptibility of various materials to corrosion and erosion under extremely high shear conditions, and how effectively (or not) film-forming corrosion inhibitors perform. The application of these advanced laboratory techniques is currently playing a vital role in evaluating suitable methods for preventing corrosion under very challenging conditions before deployment in the field.
The application of production chemicals downhole via dedicated injection lines or by means of gas lift systems, whilst not new, is becoming more commonplace in the oil and gas industry. The corrosion characteristics of injected chemical formulations in such systems can be complex and require detailed testing to understand the behaviour and assess the potential corrosion risk of chemical formulations under the extreme conditions of temperature and pressure that exist within either of these injection systems. In the presence of a fast flowing stream of hot gas, the more volatile components can be stripped from the formulated product, resulting in separate condensed vapours and chemical residues. Similarly, low-pressure vapour pockets formed within downhole chemical injection systems due to hydrostatic pressure fluctuations may cause some components of the injected chemical to be evaporated. Materials compatibility tests are commonly conducted using samples of "as supplied" production chemicals However, there is also a risk that different material compatibility/corrosivity characteristics can be induced by the condensed vapours or stripped residues of the production chemicals when compared to the originally applied chemical formulation. Laboratory testing is not commonly conducted to assess this behaviour. Samples have been prepared and corrosion tests conducted on collected vapours and residues from production chemicals. Distillations were conducted on the neat chemicals to obtain vapours and residues, and corrosion rates were measured on a range of different metallic specimens by conventional electrochemical or coupon weight loss methods. The results of these separated phase corrosion tests were then compared with the corrosion measurements on the original formulations. The test programme demonstrated that for some of the formulations tested, significantly higher corrosion rates were measured for either the condensed vapours or the distillation residues when compared to the original formulation. This work highlights the need to carefully consider the possible range of temperature/pressure conditions and gas/liquid phase interactions that will be experienced by injected chemicals within the chemical delivery system. Specifically, there is a need to assess the implications of solvent stripping/evaporation of volatile components. Chemicals that form more corrosive condensed vapours or residues may need to be avoided to prevent equipment failure or a loss of integrity. It is not adequate to simply test the ‘stability’ of a chemical at elevated temperatures, ambient pressure and static conditions; the separation effects within the gas/liquid system must also be considered.