Animals are much better at running than robots. The difference in performance arises in the important dimensions of agility, range, and robustness. To understand the underlying causes for this performance gap, we compare natural and artificial technologies in the five subsystems critical for running: power, frame, actuation, sensing, and control. With few exceptions, engineering technologies meet or exceed the performance of their biological counterparts. We conclude that biology’s advantage over engineering arises from better integration of subsystems, and we identify four fundamental obstacles that roboticists must overcome. Toward this goal, we highlight promising research directions that have outsized potential to help future running robots achieve animal-level performance.
This paper develops a comparative framework for the design of actuated inertial appendages for planar aerial reorientation. We define the inertial reorientation template, the simplest model of this behavior, and leverage its linear dynamics to reveal the design constraints linking a task with the body designs capable of completing it. As practicable inertial appendage designs lead to morphology that is generally more complex, we advance a notion of “anchoring,” whereby a judicious choice of physical design in concert with an appropriate control policy yields a system whose closed-loop dynamics are sufficiently captured by the template to permit all further designs to take place in its far simpler parameter space. This approach is effective and accurate over the diverse design spaces afforded by existing platforms, enabling a performance comparison through the shared task space. We analyze examples from the literature and find advantages to each body type, but conclude that tails provide the highest potential performance for reasonable designs. Thus motivated, we build a physical example by retrofitting a tail to a RHex robot and present empirical evidence of its efficacy.
Muscle mediates movement but movement is typically unsteady and perturbed. Muscle is known to behave non-linearly and with history dependent properties during steady locomotion, but the importance of history dependence in mediating muscles function during perturbations remains less clear. To explore muscle9s capacity to mitigate perturbations during locomotion, we constructed a series of perturbations that varied only in kinematic history, keeping instantaneous position, velocity and time from stimulation constant. We find that muscle9s perturbation response is profoundly history dependent, varying by four fold as baseline frequency changes, and dissipating energy equivalent to ∼6 times the kinetic energy of all the limbs in 5 ms (nearly 2400 W Kg−1). Muscle9s energy dissipation during a perturbation is predicted primarily by the force at the onset of the perturbation. This relationship holds across different frequencies and timings of stimulation. This history dependence behaves like a viscoelastic memory producing perturbation responses that vary with the frequency of the underlying movement.
28 May 2025 in IEEE Transactions on Medical Robotics and Bionics
The anterior cruciate ligament (ACL) is a crucial passive stabilizer of the knee joint. ACL injuries affect the anteroposterior stability of the knee joint. Many rigid knee braces with hinge designs claim to provide stabilization forces for the knee, however, current clinical practice guidelines recommend not using a functional knee brace during return to activity and return to play phases. In this study, we aimed to design a hinge-less exosuit knee brace that combines flexible materials to improve comfort at the brace-body interface while providing dynamic support forces during walking tasks using an offboard actuation system. We recruited 11 participants: 5 for design tests and 6 for walking tests. Our active exosuit knee brace was able to produce up to 88.9 N of cable force during a portion of the stance phase with a rise time of 111-150 milliseconds at different load settings and under 10N during the swing phase. Comfort scores were high (> 7) during most walking tests. The range of knee flexion was reduced by about 5 degrees when the exosuit knee brace was activated during walking, and brace migration was within 10 mm in most cases.