Marcus L. Turner

Marcus L. Turner

Auto-generated profile, based on publicly available information

Marcus L. Turner

Department of Ophthalmology, University of California, San Francisco, San Francisco, CA, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2023 in Ophthalmology Glaucoma
Verified
Journal Article
Open access
ZCZer Keen Chia
Zer Keen Chia
AKAlan W. Kong
Alan W. Kong
MTMarcus L. Turner
Marcus L. Turner
MSMurtaza Saifee
Murtaza Saifee
BDBertil E. Damato
Bertil E. Damato
YOYvonne Ou
Yvonne Ou
To assess the feasibility of remotely training glaucoma patients to take a ten-session clustered virtual reality (VR) visual field test (VVP-10) at home, analyze results for test-retest variability, and assess correspondence with conventional perimetry. Cross-sectional study. 21 subjects with glaucoma were enrolled and included in the feasibility assessment of remote training. 36 eyes were used for test-retest analysis and determination of concordance with the Humphrey Field Analyzer (HFA). Subjects were provided with a mobile VR headset containing the VVP-10 test software and trained remotely via video conferencing. Subjects were instructed to complete ten sessions over a 14-day period. Feasibility was determined by the number of subjects who were able to independently complete VVP-10 over the 14-day period after one remote training session. Intraclass correlation coefficient (ICC) of average fraction seen across ten sessions and standard error (SE) for the mean were primary outcome measures for assessing test-retest variability. Correlation with HFA mean sensitivity (MS) across eyes, was a secondary outcome measure. 20 subjects (95%) successfully completed the VVP-10 test series after one training session. ICC of VVP-10 was 0.95 (95% CI [0.92, 0.97]). Mean SE in units of fraction seen was 0.012. The Spearman correlations of VVP-10 average fraction seen versus HFA MS were 0.87 (95% CI [0.66, 0.98]) for moderate to advanced glaucoma eyes, and decreased to 0.67 (95% CI [0.28, 0.94]) when all eyes were included. Remote training of patients at home is feasible and subsequent remote clustered visual field testing using VVP-10 by patients on their own without any further interactions with caregivers or study staff was possible. At-home VVP-10 results demonstrated low test-retest variability. Future studies must be conducted to determine if VVP-10, taken at home as convenient for the patient, may be a viable supplement to provide equivalent or complementary results to that of standard in-clinic assessment of visual function in glaucoma.

10 August 2022 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
TATessnim R Ahmad
Tessnim R Ahmad
MTMarcus L Turner
Marcus L Turner
CHCharis Hoppe
Charis Hoppe
AKAlan W Kong
Alan W Kong
JBJackson S Barnett
Jackson S Barnett
MIMaanasa Indaram
Maanasa Indaram
Purpose: To assess the impact of parental socioeconomic status and keratoconus literacy on pediatric eye rubbing and keratoconus severity. Methods: In this mixed-methods study, pediatric keratoconus patients (age ≤ 18 years) were retrospectively identified. Sociodemographic and clinical characteristics were extracted from the electronic medical record (EMR). Telephone surveys were subsequently conducted to assess parental keratoconus literacy, receipt of counseling on keratoconus prevention, eye rubbing, and household socioeconomic factors not available in the EMR. Parents reporting poor keratoconus literacy were probed via semi-structured interview to explore barriers to their understanding. Results: Forty-eight patients met inclusion criteria, 22 (46%) of whom were reached by telephone. Most patients were insured by Medicaid (73%) and current eye rubbers (82%). Few parents reported good or excellent keratoconus literacy now (32%) or at the time of diagnosis (18%). Parents with a high-school education, limited English proficiency, lower income level, and Medicaid insurance tended to have lower keratoconus literacy, though this was not statistically significant. Parental keratoconus literacy was not correlated with disease severity. High-school education, limited English proficiency, lower income level, and Medicaid insurance were correlated with steeper keratometry readings, which was statistically significant for high-school education. In-depth interviews revealed parents felt unconfident with eye health in general and perceived a personal responsibility for learning more. Conclusion: This is the first study exploring keratoconus literacy from a socioeconomic perspective, demonstrating lower literacy among socioeconomically marginalized parents and a tendency toward more severe disease in their children.

21 October 2022 in Ophthalmology
Verified
Journal Article
Open access
CHCharis B. Hoppe
Charis B. Hoppe
SYSean Yonamine
Sean Yonamine
BKBrandon W. Kao
Brandon W. Kao
MTMarcus L. Turner
Marcus L. Turner
YOYvonne Ou
Yvonne Ou
JOJulius Oatts
Julius Oatts
We evaluated the noninferiority of 10.4 μl of eye drops eluted with a commercially available eye drop adapter, the Nanodropper (Nanodropper, Inc), on pupillary dilation and cycloplegia in children compared with the standard of care (SOC), 50 μl of eye drops. Prospective randomized trial. Pediatric patients scheduled for routine pupillary dilation at the University of California, San Francisco, at the Pediatric Ophthalmology Clinic were enrolled. Each participant provided 1 eye for the intervention group (Nanodropper) and 1 eye for the control group (SOC). Participants were randomized to receive small-volume dilating drops in 1 eye (Nanodropper) and SOC dilating drops in the other eye. Dilation was performed using 1 drop each of 1% cyclopentolate, 1% tropicamide, and 2.5% phenylephrine. Refraction and pupillometry were obtained before and 30 minutes after dilation. A noninferiority analysis was performed to assess change from before to after dilation in spherical equivalent and in pupil constriction percentage and maximum pupil diameter after dilation. Spherical equivalent, maximum pupil diameter, and pupil constriction percentage. One hundred eyes of 50 patients were included, with a mean ± standard deviation age of 9 ± 3 years. After controlling for baseline measurements, the spherical equivalent after dilation was 0.05 diopter (D) more (95% confidence interval [CI], −0.28 to 0.37 D) in the Nanodropper arm, which did not achieve noninferiority. Maximum pupil diameter after dilation was lower in the Nanodropper group (mean, −0.01 mm; 95% CI, −0.20 to −0.03), which did achieve noninferiority. Constriction percentage after dilation was 0.57 percentage points more (95% CI, −1.38 to 2.51 percentage points) in the Nanodropper group, which did not achieve noninferiority. Administration of eye drops using a small-volume adaptor demonstrated similar efficacy to SOC in a pediatric population. Strict noninferiority was met only for pupillary dilation and not for cycloplegia or constriction percentage; however, the small differences in the effect of the Nanodropper versus SOC on all primary outcomes were not clinically significant. We conclude that small-volume eye drops have the potential to decrease unnecessary medical waste and medication toxicity while maintaining therapeutic effect.

29 September 2022 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
MTMarcus L Turner
Marcus L Turner
ATAbu M Taha
Abu M Taha
SYSean Yonamine
Sean Yonamine
YYYinxi Yu
Yinxi Yu
MSMurtaza Saifee
Murtaza Saifee
JOJulius Oatts
Julius Oatts
Purpose: To determine the change in Humphrey visual field and clinical parameters after minimally invasive glaucoma surgery combined with cataract surgery. Patients and Methods: Patients undergoing minimally invasive glaucoma surgery combined with cataract surgery in a multicenter retrospective case series between 2013 and 2021 with reliable preoperative and 12 to 18 month postoperative visual field measurements were included. Devices included iStent, XEN, and Hydrus. Clinical parameters were compared with a generalized linear model with generalized estimating equations between preoperative and postoperative visits including best corrected visual acuity, intraocular pressure, number of glaucoma medications and visual fields. Visual field metrics included mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), and Collaborative Initial Glaucoma Treatment Study (CIGTS) score of total deviation probability and pattern deviation probability. Results: Forty-four eyes from 39 patients were included. During the follow up period, visual acuity improved from 0.23± 0.17 to 0.10± 0.14 logMAR (mean ± standard deviation, p< 0.001), number of glaucoma medications was reduced from 2.68± 1.06 to 1.46± 1.32 (p< 0.001), and intraocular pressure decreased from 17.08± 4.23 mmHg to 14.92± 3.13 mmHg (p=0.003). Differences across devices were negligible. The only significant difference was a greater reduction in number of glaucoma medications in the XEN group (p< 0.001). There were no significant changes in the global parameters of VFI, MD, PSD, or CIGTS. Conclusion: Overall, minimally invasive glaucoma surgery combined with cataract surgery appears to be effective at stabilizing visual field function, reducing intraocular pressure, reducing number of glaucoma medications, and improving visual acuity over a 12 to 18 month follow-up period across MIGS devices.

29 September 2022 in Ophthalmology Glaucoma
Verified
Journal Article
Closed access
MTMarcus Turner
Marcus Turner
YOYvonne Ou
Yvonne Ou

14 October 2022 in American Journal of Ophthalmology Case Reports
Verified
Journal Article
Open access
MTMarcus L. Turner
Marcus L. Turner
ACAlejandra G. de Alba Campomanes
Alejandra G. de Alba Campomanes
JSJay Stewart
Jay Stewart
JOJulius Oatts
Julius Oatts
To report a case of congenital ciliary body cysts causing microspherophakia, ectopia lentis, and secondary angle closure glaucoma in an infant. A 16-month-old male was found to have bilateral ciliary body cysts associated with zonular laxity or absence causing microspherophakia and ectopia lentis as demonstrated on multimodal imaging. Additionally, the patient had secondary angle closure glaucoma which was likely multi-factorial related to both lens abnormalities and anterior displacement of the iris from the cysts themselves. The patient underwent lensectomy and cyst removal which resulted in intraocular pressure stabilization and visual rehabilitation. Congenital ciliary body cysts are a rare cause of lens abnormalities and secondary angle closure glaucoma in children. Information regarding genetic underpinnings or systemic associations is limited.