Deven K. Gupta

Deven K. Gupta

Auto-generated profile, based on publicly available information

Deven K. Gupta

Duke University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2025 in Optics Letters
Verified
Journal Article
Closed access
KLKechao Lu
Kechao Lu
YXYirui Xu
Yirui Xu
DMDavid A. Miller
David A. Miller
WWWan Wang
Wan Wang
DGDeven Gupta
Deven Gupta
AWAdam Wax
Adam Wax
Optical scattering in biological tissues presents a major challenge for achieving deep penetration in optical coherence tomography (OCT). Recent approaches leveraging the Kramers–Kronig (KK) relations suggest that strongly absorbing dyes can reduce scattering by modulating the tissue’s refractive index. In this study, we investigate the use of indocyanine green (ICG), an FDA clinically approved near-infrared dye, as an optical clearing agent (OCA) for 1300 nm OCT imaging. Due to its strong absorption near 780 nm and its binding affinity to plasma proteins and lipids, ICG presents a promising candidate for KK-based optical clearing in fatty tissues. We validated ICG’s clearing potential using 1300 nm OCT on the abdominal skin of a non-pigmented mouse for in vivo imaging. Our findings indicate that ICG enhances imaging contrast and increases penetration depth, demonstrating its potential for non-invasive, contrast-enhanced 1300-OCT imaging. These findings could benefit dermatological applications of OCT by enhancing image quality to reveal greater detail in the skin.

31 July 2024 in Optics Letters
Verified
Journal Article
Closed access
PDF file
DGDeven K. Gupta
Deven K. Gupta
RHRobert Highland
Robert Highland
DMDavid A. Miller
David A. Miller
AWAdam Wax
Adam Wax
We demonstrate the use of a novel, to the best of our knowledge, localization algorithm for digitally refocusing fluorescence images from a three-dimensional cell culture. Simultaneous phase and fluorescence intensity images are collected through a multimodal system that combines digital holography via quantitative phase microscopy (QPM) and fluorescence microscopy. Defocused fluorescence images are localized to a specific z-plane within the three-dimensional (3D) matrix using the transport of intensity equation (TIE) and depth-resolved information derived from the QPM measurements. This technique is applied to cells stained with different fluorescent tags suspended in 3D collagen hydrogel cultures. Experimental findings demonstrate the localization of defocused images, facilitating the analysis and comparison of cells within the hydrogel matrix. This method holds promise for comprehensive cellular imaging of fluorescence labeling in three-dimensional environments, enabling detailed investigations into cellular behavior and interactions.

25 February 2021 in Surgical Innovation
Verified
Journal Article
Closed access
PDF file
DGDeven K. Gupta
Deven K. Gupta
LCLily Chen
Lily Chen
AHAndrew E. Heidari
Andrew E. Heidari
SCSteven Chau
Steven Chau
BDBrandyn Dunn
Brandyn Dunn
BWBrian J.-F. Wong
Brian J.-F. Wong
Need. Battery-powered Light Emitting Diode (LED) surgical headlights are necessary for improved intraoperative illumination but may be costly. Technical Solution. The objective of this study was to develop a low-cost surgical headlight using a consumer-grade LED headlight and 3D-printed mount. Proof of Concept. Eighteen surgical residents performed simulation exercises that mimicked suturing in the oral cavity using both a custom prototype headlight and a commercial surgical headlight. The time required to complete the task with each headlight was recorded along with an exit survey. A second device was created based on the critiques of the first device and was tested by ten additional surgical trainees. Surgical residents completed the simulation task in 27 ± 8.6 seconds and 21 ± 5.6 seconds with the commercially available headlight and first prototype, respectively. In the second experiment, the simulation task was completed in 23 ± 11.1 and 23 ± 12.2 seconds with the commercially available headlight and second device, respectively. Survey results showed an overall positive consensus, with critiques about headband security, suggestions for smaller LED chassis, and a more robust mounting bracket. Some preferred the prototype headlight due to the wider field of illumination compared to the commercially available unit (ie, beam spread/beam angle). Next Steps. Future adjustments are required to optimize the location of the headlight and the battery to modify the weight distribution of the device. Conclusion. These findings demonstrate that our prototype models are viable alternatives to conventional surgical headlights and warrant continued optimization for broader adoption by surgeons and trainees for whom higher-cost alternatives are not an option.