Patrick Kwiatkowski

Patrick Kwiatkowski

Auto-generated profile, based on publicly available information

Patrick Kwiatkowski

Institute of Integrated Systems, Ruhr University Bochum, Bochum, Germany

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2025 in IEEE Journal of Radio Frequency Identification
Verified
Journal Article
Open access
PKPatrick Kwiatkowski
Patrick Kwiatkowski
SHSteffen Hansen
Steffen Hansen
AOAlexander Orth
Alexander Orth
FFFrancisco Geu Flores
Francisco Geu Flores
FHFalko Heitzer
Falko Heitzer
NPNils Pohl
Nils Pohl
Optimized rehabilitation after joint replacement surgery or other medical procedures affecting the musculoskeletal system requires practical movement analysis systems that enable the continuous and precise gait monitoring of patients in everyday life. To address this need, we present a system consisting of a frequency-modulated continuous-wave (FMCW) radar sensor and active frequency-doubling tags designed for accurate long-term monitoring. By using a harmonic measurement concept in which the tags double the frequency of the transceiver signal, a high signal-to-interference-and-noise ratio (SINR) is achieved, ensuring that the tags stand out clearly from the clutter produced by the leg. With our system, we particularly focus on a phase-based angle determination within the sagittal plane, enabled by two closely spaced receive antennas, allowing for more accurate and reliable gait monitoring compared to our previous system based on a bilateration method. By utilizing millimeter waves in the frequency range 56-63 GHz for transmission and 112-126 GHz for reception, we achieve a compact sensor size sufficient for the application. Based on measurements taken in a gait laboratory, we demonstrate that our system is capable of measuring the distance and angle between the sensor and tags during gait with an accuracy of up to 1.73 mm and 0.93°, respectively, using a stationary camera-based motion capture (MoCap) system as a reference.

7 March 2024 in International Journal of Microwave and Wireless Technologies
Verified
Journal Article
Open access
PDF file
PKPatrick Kwiatkowski
Patrick Kwiatkowski
AOAlexander Orth
Alexander Orth
NPNils Pohl
Nils Pohl
In this paper, we introduce a compact 6 × 8 channel multiple-input multiple-output frequency-modulated continuous-wave radar system capable of determining the three-dimensional positions of targets despite utilizing a linear virtual array. The compact system, containing two cascaded radar transceiver ICs, has 48 virtual channels. We conduct a direction of arrival estimation with these virtual channels to determine the azimuth angle. To overcome the spatial limitation of the linear array, we use frequency-steered transmit antennas, which vary their main lobe direction during the frequency chirp, allowing the elevation angle to be determined by using a sliding window fast Fourier transform algorithm. In this study, we present the system’s concept along with the associated signal processing. By taking measurements in different scenarios, each with differently placed corner reflectors, we investigate the capability of the system to separate adjacent targets concerning range, azimuth, and elevation. These measurements are additionally employed to point out the design trade-offs inherent to the system.