27 February 2017 in Analytical Chemistry
21 March 2016 in Journal of Analytical Atomic Spectrometry
In this study, a highly sensitive liquid electrode discharge atomic emission source was developed for the determination of Cd and Zn in aqueous solutions. In contrast to the common electrolyte cathode atmospheric glow discharge (ELCAD) approach, the source utilizes an electrolyte solution containing the analyte as the anode. With this design, the sensitivity of Cd and Zn is significantly enhanced and LODs could be improved by at least one order of magnitude. In this approach, the volatile species of Cd and Zn can be readily generated at the plasma–liquid interface probably resulting from electron transfer reactions at the plasma–liquid interface, which greatly increase the sample introduction efficiency, and thus provide high sensitivity. In addition, the device operates comfortably at low power (<7 W). The effects of operating parameters such as electrolyte pH, discharge current, Ar gas flow rate and sample introduction rate were investigated. The LODs were calculated to be 0.05 μg L−1 for Cd and 0.14 μg L−1 for Zn under optimized conditions. The repeatability values, expressed as the relative standard deviation of the emission signals, for four replicate measurements of 10 μg L−1 of Cd and Zn were 3.8% and 4.0% respectively. The proposed excitation source provides a low-cost, low power consumption and sensitive method for the determination of Cd and Zn at ultra-trace levels.
7 March 2011 in Journal of Analytical Atomic Spectrometry
An atmospheric pressure plasma sustained by an alternating-current power supply was generated using the electrolyte solution as one electrode. The emission spectra of the plasma are related to the metal ions present in the solution and thus can be used for metal ion detection. The main advantage of this source is that it operates at low flow rates in the range of 0.1 to 0.8 mL/min. The effects of the discharge electrolyte anion, the pH and solution flow rate on emission signal were studied. The analytical response curves for Na and Cd demonstrated good linearity at least in the range of 0.5–100 mg L−1. The limit of detection of Na and Cd were determined to be 0.04 and 0.09 mg L−1, respectively. The method was applied for the determination of elements in simulated natural water samples (GBW(E)080408 and GBW(E)080402). The obtained results were in good agreement with the reference values. It provides an alternative analytical method for the determination of elements in water samples.
28 February 2017 in Analytical Chemistry
13 March 2013 in Analytical Chemistry
21 September 2011 in The Analyst
This paper describes a low-temperature dielectric barrier discharge (DBD)-plasma induced vaporization technique using mercury as a model analyte. The evaporation and atomization of dissolved mercury species in the sample solution can be achieved rapidly in one step, allowing mercury to be directly detected by atomic fluorescence spectrometry. The DBD plasma was generated concentrically in-between two quartz tube (outer tube: i.d. 5 mm and o.d. 6 mm, inner tube: i.d. 2 mm and o.d. 3 mm). A copper electrode was embedded inside the inner quartz tube and sample solution was applied onto the outer surface of the inner tube. The effects of operating parameters such as plasma power, plasma gas identity, plasma gas flow rate and interferences from concomitant elements have been investigated. The difference in the sensitivities of Hg2+, methylmercury (MeHg) and ethylmercury (EtHg) was found to be negligible in the presence of formic acid (≥1% v/v). The analytical performance of the present technique was evaluated under optimized conditions. The limits of detection were calculated to be 0.02 ng mL−1 for Hg2+, MeHg and EtHg, and repeatability was 6.2%, 4.9% and 4.3% RSD (n = 11) for 1 ng mL−1 of Hg2+, MeHg and EtHg, respectively. This provides a simple mercury detection method for small-volume samples with an absolute limit of detection at femtogram level. The accuracy of the system was verified by the determination of mercury in reference materials including freeze-dried urine ZK020-2, simulated water matrix reference material GBW(E) 080392 and tuna fish GBW10029, and the concentration of mercury determined by the present method agreed well with the reference values.