James W. White

James W. White

Auto-generated profile, based on publicly available information

James W. White

Department of Exercise Science, University of South Carolina, Columbia, SC, United States of America

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JWJames W. White
James W. White
OFOlivia L. Finnegan
Olivia L. Finnegan
NTNick Tindall
Nick Tindall
SNSrihari Nelakuditi
Srihari Nelakuditi
DBDavid E. Brown
David E. Brown
GWGlenn Weaver
Glenn Weaver
The purpose of this study was to evaluate the reliability and validity of the raw accelerometry output from research-grade and consumer wearable devices compared to accelerations produced by a mechanical shaker table. Raw accelerometry data from a total of 40 devices (i.e., n = 10 ActiGraph wGT3X-BT, n = 10 Apple Watch Series 7, n = 10 Garmin Vivoactive 4S, and n = 10 Fitbit Sense) were compared to reference accelerations produced by an orbital shaker table at speeds ranging from 0.6 Hz (4.4 milligravity-mg) to 3.2 Hz (124.7mg). Two-way random effects absolute intraclass correlation coefficients (ICC) tested inter-device reliability. Pearson product moment, Lin’s concordance correlation coefficient (CCC), absolute error, mean bias, and equivalence testing were calculated to assess the validity between the raw estimates from the devices and the reference metric. Estimates from Apple, ActiGraph, Garmin, and Fitbit were reliable, with ICCs = 0.99, 0.97, 0.88, and 0.88, respectively. Estimates from ActiGraph, Apple, and Fitbit devices exhibited excellent concordance with the reference CCCs = 0.88, 0.83, and 0.85, respectively, while estimates from Garmin exhibited moderate concordance CCC = 0.59 based on the mean aggregation method. ActiGraph, Apple, and Fitbit produced similar absolute errors = 16.9mg, 21.6mg, and 22.0mg, respectively, while Garmin produced higher absolute error = 32.5mg compared to the reference. ActiGraph produced the lowest mean bias 0.0mg (95%CI = -40.0, 41.0). Equivalence testing revealed raw accelerometry data from all devices were not statistically significantly within the equivalence bounds of the shaker speed. Findings from this study provide evidence that raw accelerometry data from Apple, Garmin, and Fitbit devices can be used to reliably estimate movement; however, no estimates were statistically significantly equivalent to the reference. Future studies could explore device-agnostic and harmonization methods for estimating physical activity using the raw accelerometry signals from the consumer wearables studied herein.

4 June 2023 in medRxiv
Verified
Preprint
Open access
PDF file
JWJames W. White
James W. White
OFOlivia Finnegan
Olivia Finnegan
NTNick Tindall
Nick Tindall
SNSrihari Nelakuditi
Srihari Nelakuditi
DBDavid E. Brown
David E. Brown
GWGlenn Weaver
Glenn Weaver
The purpose of this study was to evaluate the reliability and validity of the raw accelerometry output from research-grade and consumer wearable devices compared to accelerations produced by a mechanical shaker table. Raw accelerometry data from a total of 40 devices (i.e., n=10 ActiGraph wGT3X-BT, n=10 Apple Watch Series 7, n=10 Garmin Vivoactive 4S, and n=10 Fitbit Sense) were compared to the criterion accelerations produced by an orbital shaker table at speeds ranging from 0.6 Hz (4.4 milligravity-mg) to 3.2 Hz (124.7mg). For reliability testing, identical devices were oscillated at 0.6 and 3.2 Hz for 5 trials that lasted 2 minutes each. For validity testing, devices were oscillated for 1 trial across 7 speeds that lasted 2 minutes each. The intraclass correlation coefficient (ICC) was calculated to test inter-device reliability. Pearson product moment, Lin’s concordance correlation coefficient (CCC), absolute error, and mean bias were calculated to assess the validity between the raw estimates from the devices and the criterion metric. Estimates produced by the raw accelerometry data from Apple and ActiGraph were more reliable ICCs=0.99 and 0.97 than Garmin and Fitbit ICCs=0.88 and 0.88, respectively. Estimates from ActiGraph, Apple, and Fitbit devices exhibited excellent concordance with the criterion CCCs=0.88, 0.83, and 0.85, respectively, while estimates from Garmin exhibited moderate concordance CCC=0.59 based on the mean aggregation method. ActiGraph, Apple, and Fitbit produced similar absolute errors=16.9mg, 21.6mg, and 22.0mg, respectively, while Garmin produced higher absolute error=32.5mg compared to the criterion based on the mean aggregation method. ActiGraph produced the lowest mean bias 0.0mg (95%CI=-40.0, 41.0) based on the mean aggregation method. Raw accelerometry data collected from Apple and Fitbit are comparable to ActiGraph. However, raw accelerometry data from Garmin appears to be different. Future studies may be able to develop algorithms using device-agnostic methods for estimating physical activity from consumer wearables.