Introduction The generic metabolomics data processing workflow is constructed with a serial set of processes including peak picking, quality assurance, normalisation, missing value imputation, transformation and scaling. The combination of these processes should present the experimental data in an appropriate structure so to identify the biological changes in a valid and robust manner. Objectives Currently, different researchers apply different data processing methods and no assessment of the permutations applied to UHPLC-MS datasets has been published. Here we wish to define the most appropriate data processing workflow. Methods We assess the influence of normalisation, missing value imputation, transformation and scaling methods on univariate and multivariate analysis of UHPLC-MS datasets acquired for different mammalian samples. Results Our studies have shown that once data are filtered, missing values are not correlated with m/z, retention time or response. Following an exhaustive evaluation, we recommend PQN normalisation with no missing value imputation and no transformation or scaling for univariate analysis. For PCA we recommend applying PQN normalisation with Random Forest missing value imputation, glog transformation and no scaling method. For PLS-DA we recommend PQN normalisation, KNN as the missing value imputation method, generalised logarithm transformation and no scaling. These recommendations are based on searching for the biologically important metabolite features independent of their measured abundance. Conclusion The appropriate choice of normalisation, missing value imputation, transformation and scaling methods differs depending on the data analysis method and the choice of method is essential to maximise the biological derivations from UHPLC-MS datasets.
1 June 2015 in TrAC Trends in Analytical Chemistry
The epitaxial lift-off (ELO) process is utilized to produce thin-film III-V devices, while the substrate (GaAs wafer) on which the III-V structure was grown can be reused. However, so far the direct reuse of these GaAs wafers is inhibited by the remnants on the wafer surface that cannot be removed in a straightforward fashion utilizing general cleaning methods. Therefore, etching of GaAs wafers in hydrofluoric acid was investigated by microscopic techniques, profilometry and X-ray photoelectron spectroscopy. It was found that immediately after etching the wafer surface is covered by a brown layer of elemental arsenic. The thickness and uniformity of this layer depend on both illumination during etching and the HF concentration. During storage of the etched wafer the As layer is replaced by As2O3 particles. It is shown that oxide particles form only when the wafer is exposed to light in the presence of air. A model that explains the As formation and the subsequent particle formation is given.