Toshifumi Mihashi

Toshifumi Mihashi

Auto-generated profile, based on publicly available information

Toshifumi Mihashi

Affiliations Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Tsukuba-city, Ibaraki, Japan, Department of Orthoptics, Faculty of Medical Technology, Teikyo University, Itabashi, Tokyo, Japan

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MNMasashi Nakajima
Masashi Nakajima
THTakahiro Hiraoka
Takahiro Hiraoka
TYToshiya Yamamoto
Toshiya Yamamoto
STSeiu Takagi
Seiu Takagi
YHYoko Hirohara
Yoko Hirohara
TMToshifumi Mihashi
Toshifumi Mihashi
Several researchers have studied the longitudinal chromatic aberration (LCA) of eyes implanted with an intraocular lens (IOL). We investigated the LCA of eyes implanted with yellow-colored IOLs from three different manufacturers: Alcon Inc., HOYA Corp., and AMO Inc. The number of subjects was 11, 16, and 16, respectively. The LCA of eyes implanted with SN60WF and SN60AT (Alcon Inc.), and with XY-1 (HOYA Corp.), was the same as that of phakic eyes. The LCA of eyes with ZCB00V (AMO Inc.) was smaller than that of phakic eyes. The LCA of eyes implanted with Alcon’s and HOYA’s IOLs, but not the LCA of eyes implanted with AMO’s IOLs, was positively correlated with the powers of the IOLs. We also performed simulations to verify the impacts of LCA on visual performance for 4-mm pupil diameter; the simulations were a polychromatic modulation transfer function (MTF) and a visual Strehl ratio computed on the basis of an optical transfer function (VSOTF). We concluded that the differences between the LCA of different manufacturers do not affect visual performances when some extent of higher-order aberration (HOA) exists. The smaller HOA of AMO IOLs may enhance visual performance.

1 April 2013 in Experimental Eye Research
Verified
Journal Article
Closed access
YHY. Hirohara
Y. Hirohara
TMT. Mihashi
T. Mihashi
Hiroyuki KandaHiroyuki Kanda
Hiroyuki Kanda
TMTakeshi Morimoto
Takeshi Morimoto
TMT. Miyoshi
T. Miyoshi
TFT. Fujikado
T. Fujikado

20 June 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
TYTatsuo YAMAGUCHI
Tatsuo YAMAGUCHI
TMToshifumi Mihashi
Toshifumi Mihashi
YKYoshiyuki Kitaguchi
Yoshiyuki Kitaguchi
Hiroyuki KandaHiroyuki Kanda
Hiroyuki Kanda
TMTakeshi Morimoto
Takeshi Morimoto
TFTakashi Fujikado
Takashi Fujikado
We introduce a newly developed adaptive optics dioptric scanning ophthalmoscope (AO-DSO) in which all powered optical parts were refractive lenses instead of concave or convex mirrors. By designing dioptric optics, we were able to achieve a compact instrument with a 10 deg field of view (FOV10) and 1.5 deg field of view (FOV1.5) high-resolution imaging. Although the resolution of FOV10 was sacrificed because of the variation of aberrations of the eye over the 10 deg field, our system works with AO in the case of FOV1.5 and can be used as a scanning laser ophthalmoscope with good optical slicing in the case of FOV10. To test the ability of the AO-DSO, we performed imaging on a normal subject and on a patient with occult macular dystrophy.

23 June 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
THTetsuya Horiuchi
Tetsuya Horiuchi
TMToshifumi Mihashi
Toshifumi Mihashi
Sujin HoshiSujin Hoshi
Sujin Hoshi
Fumiki OkamotoFumiki Okamoto
Fumiki Okamoto
TOTetsuro Oshika
Tetsuro Oshika
The current method of controlling the focus of an accommodating intraocular lens is based on ciliary muscle contraction and cannot be used in older patients with presbyopia. We aimed to develop a dynamically accommodating intraocular lens powered by a membrane-shaped ion polymer metal composite actuator that is thin enough to be inserted in the eye. This study addresses two key problems identified in our previous accommodating intraocular lens prototype: the lack of repeatability due to the use of swine lenses instead of artificial lenses and the occurrence of a sixth order aberration. Thus, we present a new accommodating intraocular lens design and a method to transfer energy to actuators. To accommodate lens deformation and depth of focus, we used a membrane-shaped ion polymer metal composite actuator, thin enough to be inserted in the eye, and used an artificial silicone lens. To prevent the sixth order aberration, we included a ring between the ion polymer metal composite actuator and the lens. Different voltage patterns were applied to the IPMC actuator and changes in focus were observed. We were able to obtain repeatability and prevent the sixth order aberration. The dioptric power changed to ±0.23 D when ±1.5 V was used; however, at >1.5 V, a large accommodating range occurred, in addition to astigmatic vision. Thus, we have developed a novel prototype that is completely artificial, allowing reproducible and repeatable results. Visual accommodative demands were successfully met; however, although astigmatic vision was lessened, it was not completely eradicated.

1 March 2003 in Seminars in Ophthalmology
Verified
Journal Article
Closed access
TMToshifumi Mihashi
Toshifumi Mihashi
The purpose was to investigate the effect of decentered ablation in myopic corneal refractive surgery by simulation. Wavefront aberrations in a small pupil area (radius: 2 mm) for photopic vision and in a large pupil area (radius: 3 mm) for mesopic vision with simulated refractive surgery were analyzed using Zernike polynomials. Radii of ablation were 3, 2.5 and 2 mm. Decentrations of ablation were 0 mm and 0.5 mm. Change of the surface shape by ablation was considered a perturbation, while Gullstrand’s schematic eye was used as un-perturbed optics. For photopic vision, wavefront aberrations were about the same as with unperturbed optics. For mesopic vision, the results were heavily dependent on the radius of ablation area. When the radius was 3 mm, wavefront aberrations did not increase very much compared to un-perturbed optics. When the radius was smaller than 3 mm, spherical aberration was induced by centered ablations, and coma was also induced by decentered ablations. In conclusion, small ablation areas or subclinical decentrations of ablations could cause serious amounts of wavefront aberrations to the optics of the eye in the simulations.