Alaa Gamal Sheriff

Alaa Gamal Sheriff

Auto-generated profile, based on publicly available information

Alaa Gamal Sheriff

Civil Department, Faculty of Engineering, Mataria, Helwan University, Egypt

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Ain Shams Engineering Journal
Verified
Journal Article
Open access
NHNasr Z. Hassan
Nasr Z. Hassan
ASAlaa G. Sherif
Alaa G. Sherif
AZAmal H. Zamarawy
Amal H. Zamarawy
Transverse openings are often provided through reinforced concrete beams to accommodate utility ducts and pipes. Finite element analysis has been used in order to study this problem. Fifty-seven beams analyzed using finite element program ANSYS V12. The analysis results compared with fifteen experimental beams had been done by Ibrahim. Study beams have opening width and height of dimensions 200×100mm and 300×100mm. The centerline of the opening is at distance of 225, 300, 350 and 400mm from the near support. Strengthening of all beams with opening came out to six types of different scheme around the opening using fiber-reinforced polymer (FRP). Scheme (1) is vertical and horizontal carbon fiber sheets around the opening, scheme (2) is inclined at 45° carbon fiber sheets around the opening in addition to horizontal one, schemes (3) and (4) are same of schemes (1) and (2) respectively but with glass fiber sheets, while schemes (5) and (6) are same as schemes (3) and (4) respectively but with an additional strengthening at flexural area at the middle of the beam with U shape. The reinforced concrete beams were modeled in ‘ANSYS V12’ Program under statical load. The failure loads, crack pattern, strain progress, mode of failure and energy absorption were analyzed here in this study

1 July 2006 in ACI Structural Journal
Verified
Journal Article
Closed access
PDF file
JHJosef Hegger
Josef Hegger
ASAlaa G. Sherif
Alaa G. Sherif
MRMarcus Ricker
Marcus Ricker

1 September 2009 in ACI Structural Journal
Verified
Journal Article
Closed access
PDF file
JHJosef Hegger
Josef Hegger
MRMarcus Ricker
Marcus Ricker
ASAlaa G. Sherif
Alaa G. Sherif

1 March 2009 in Engineering Structures
Verified
Journal Article
Closed access
KCKyoung-Kyu Choi
Kyoung-Kyu Choi
ASAlaa G. Sherif
Alaa G. Sherif
Mahmoud Reda TahaMahmoud Reda Taha
Mahmoud Reda Taha
LCLan Chung
Lan Chung

1 October 1996 in Canadian Journal of Civil Engineering
Verified
Journal Article
Closed access
ASAlaa G. Sherif
Alaa G. Sherif
WDWalter H. Dilger
Walter H. Dilger
The purpose of this paper is to demonstrate that the shear design of slabs according to the relevant Canadian CSA A23.3-94 (and U.S. ACI 318-95) design codes can be unsafe under certain conditions, and to propose improved design equations, some of which should be considered immediately for implementation in the Canadian CSA code. The paper deals with interior slab–column connections, with and without shear reinforcement, subjected to shear force alone or to a combination of shear force and unbalanced bending moment. Some comparisons with the British code BS 8110-85 and the CEB –FIP model code 1990 are also made. Tests reported in the literature and some experiments by the authors provide the basis for this study. Key words: flat concrete plates, slab–column connections, shear strength, punching shear, shear reinforcement, moment transfer.

1 April 2018
Verified
Conference Paper
Closed access
NMNohaira S. Morsy
Nohaira S. Morsy
ASAlaa G. Sherif
Alaa G. Sherif
ASAta E. Shoeib
Ata E. Shoeib
MAMohamed Helmy Agamy
Mohamed Helmy Agamy