Hanieh Hadady

Hanieh Hadady

Auto-generated profile, based on publicly available information

Hanieh Hadady

University of Nevada, Reno, Reno, NV

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in AIMS Biophysics
Verified
Journal Article
Open access
PDF file
HHHanieh Hadady
Hanieh Hadady
DRDoug Redelman
Doug Redelman
SHSage Hiibel
Sage Hiibel
EGEmil J. Geiger
Emil J. Geiger
This paper presents a continuous-flow cell screening device to isolate and separate microalgae cells (Chlamydomonas reinhardtii) based on lipid content using high frequency (50 MHz) dielectrophoresis. This device enables screening of microalgae due to the balance between lateral DEP forces relative to hydrodynamic forces. Positive DEP force along with amplitude-modulated electric field exerted on the cells flowing over the planar interdigitated electrodes, manipulated low-lipid cell trajectories in a zigzag pattern. Theoretical modelling confirmed cell trajectories during sorting. Separation quantification and sensitivity analysis were conducted with time-course experiments and collected samples were analysed by flow cytometry. Experimental testing with nitrogen starveddw15-1 (high-lipid, HL) and pgd1 mutant (low-lipid, LL) strains were carried out at different time periods, and clear separation of the two populations was achieved. Experimental results demonstrated that three populations were produced during nitrogen starvation: HL, LL and low-chlorophyll (LC) populations. Presence of the LC population can affect the binary separation performance. The continuous-flow micro-separator can separate 74% of the HL and 75% of the LL out of the starting sample using a 50 MHz, 30 voltages peak-to-peak AC electric field at Day 6 of the nitrogen starvation. The separation occurred between LL (low-lipid: 86.1% at Outlet # 1) and LC (88.8% at Outlet # 2) at Day 9 of the nitrogen starvation. This device can be used for onsite monitoring; therefore, it has the potential to reduce biofuel production costs

17 September 2014 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
HHHanieh Hadady
Hanieh Hadady
JWJohnson J. Wong
Johnson J. Wong
SHSage R. Hiibel
Sage R. Hiibel
DRDoug Redelman
Doug Redelman
EGEmil J. Geiger
Emil J. Geiger

20 May 2021 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
HHHanieh Hadady
Hanieh Hadady
FKFereshteh Karamali
Fereshteh Karamali
Fatemeh EjeianFatemeh Ejeian
Fatemeh Ejeian
SJShaghayegh Haghjooy Javanmard
Shaghayegh Haghjooy Javanmard
LRLaleh Rafiee
Laleh Rafiee
MNMohammad Hossein Nasr-Esfahani
Mohammad Hossein Nasr-Esfahani

27 March 2015 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
HHHanieh Hadady
Hanieh Hadady
CMCaroline Montiel
Caroline Montiel
DWDaniel Wetta
Daniel Wetta
EGEmil J. Geiger
Emil J. Geiger

13 August 2021 in Research Square
Verified
Preprint
Open access
PDF file
HHHanieh Hadady
Hanieh Hadady
FKFereshteh Karamali
Fereshteh Karamali
FEFatemeh Ejeian
Fatemeh Ejeian
SSSareh Sorooshzadeh
Sareh Sorooshzadeh
MNMohammad Hossein Nasr-Esfahani
Mohammad Hossein Nasr-Esfahani
Retinal degeneration (RD) is recognized as a frequent cause of visual impairments, including inherited (Retinitis pigmentosa) and degenerative (age-related macular) eye diseases. Recently, dental stem cells (DSCs) have demonstrated a promising neuroprotection potential for ocular diseases through a paracrine manner carried out by extracellular vesicles (EVs). However, effective isolation of EVs is still challenging, and isolation methods determine the composition of enriched EVs and the subsequent biological and functional effects. In the present study, we assessed two enrichment methods (micro-electromechanical systems and ultrafiltration) to isolate the EVs from stem cells from apical papilla (SCAP). The size distribution of the corresponding isolates exhibited the capability of each method to enrich different subsets of EVs, which significantly impacts their biological and functional effects. We confirmed the neuroprotection and anti-inflammatory capacity of the SCAP-EVs in vitro. Further experiments revealed the possible therapeutic effects of subretinal injection of SCAP-EVs in the Royal College of Surgeons (RCS) rat model. We found that EVs enriched by the micro-electromechanical-based device (MEMS-EVs) preserved visual function, reduced retinal cell apoptosis, and prevented thinning of the outer nuclear layer (ONL). Interestingly, the effect of MEMS-EVs was extended to the retinal ganglion cell/nerve fiber layer (GCL/NFL). This study supports the use of the microfluidics approach to enrich valuable subsets of EVs, together with the choice of SCAP as a source to derive EVs for cell-free therapy of RD.

14 November 2014
Verified
Conference Paper
Closed access
PDF file
HHHanieh Hadady
Hanieh Hadady
JWJohnson J. Wong
Johnson J. Wong
SHSage R. Hiibel
Sage R. Hiibel
EGEmil J. Geiger
Emil J. Geiger
A method was developed for analyzing the high frequency dielectrophoresis (>20 MHz) response of microalgal cells with different lipid content on the basis of media conductivities. At these frequencies, the DEP response is expected to depend primarily on the dielectric properties of the cytoplasm. The medium used to perform DEP experiments has an important influence on their outcome since all properties are measured in relation to the medium, therefore its properties must be tightly controlled. This method is label free and only uses electric fields, and thus it is suitable for many other applications in the medical field. Chlamydomonas reinhardtii cells were cultured in regular medium and then the same cells were cultured under nitrogen-free conditions to accumulate neutral (non-polar) lipids. To measure the upper crossover frequency, two thin, needle shaped electrodes (100 nm thick) were patterned onto a glass slide using standard micro-technology processes and the motion of the cells was observed as an AC signal was swept from 20–80 MHz at ∼30Vpp (Volt peak to peak). Cells were injected to the microelectrode array in different medium conductivities that were adjusted by sodium chloride. The upper crossover frequencies of N-free cells in different media conductivities were measured. It was found that when the solution conductivity was between 4 ± 2 μs/cm and 106 ± 1 μS/cm and the operating frequency was between 20 and 80 MHz, the upper crossover frequency of the microalgae increased as the medium conductivity increased. The lipid content was verified via fluorescence microscopy and MATLAB image processing.