Nien-Hui Ge

Nien-Hui Ge

Auto-generated profile, based on publicly available information

Nien-Hui Ge

Department of Chemistry, University of California , Irvine, California 92697-2025

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2017 in Optics Express
Verified
Journal Article
Closed access
PDF file
YFYuan Feng
Yuan Feng
IVIlya Vinogradov
Ilya Vinogradov
NGNien-Hui Ge
Nien-Hui Ge
We devised a novel two-step reference scheme that can greatly suppress the additive and convolutional noises in heterodyne nonlinear spectroscopy. To optimally remove additive noise, we fully utilized the spectral correlation in multi-channel reference data through a linear combination and regression algorithm. Using our pump-probe 2D IR spectrometer, we demonstrated that our scheme can improve the signal-to-noise ratio by 10-30 times and reach the noise floor of the signal detector. The new algorithm is guaranteed to reduce noise, enables the use of unmatched reference detectors, and does not introduce baseline shift or signal distortion. This scheme is applicable to many heterodyne spectroscopic techniques.

15 May 2013 in The Journal of Physical Chemistry B
Verified
Journal Article
Open access
YHYang Han
Yang Han
VRVarun Raghunathan
Varun Raghunathan
RFRan-Ran Feng
Ran-Ran Feng
HMHiroaki Maekawa
Hiroaki Maekawa
CCChao-Yu Chung
Chao-Yu Chung
NGNien-Hui Ge
Nien-Hui Ge
We demonstrate a phase sensitive, vibrationally resonant sum-frequency generation (PSVR-SFG) microscope that combines high resolution, fast image acquisition speed, chemical selectivity, and phase sensitivity. Using the PSVR-SFG microscope, we generate amplitude and phase images of the second-order susceptibility of collagen I fibers in rat tail tendon tissue on resonance with the methylene vibrations of the protein. We find that the phase of the second-order susceptibility shows dependence on the effective polarity of the fibril bundles, revealing fibrous collagen domains of opposite orientations within the tissue. The presence of collagen microdomains in tendon tissue may have implications for the interpretation of the mechanical properties of the tissue.

16 September 2010 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
HMHiroaki Maekawa
Hiroaki Maekawa
GBGema Ballano
Gema Ballano
CTClaudio Toniolo
Claudio Toniolo
NGNien-Hui Ge
Nien-Hui Ge

4 June 2009 in The Journal of Physical Chemistry B
Verified
Journal Article
Open access
NSNeelanjana Sengupta
Neelanjana Sengupta
HMHiroaki Maekawa
Hiroaki Maekawa
WZWei Zhuang
Wei Zhuang
CTClaudio Toniolo
Claudio Toniolo
SMShaul Mukamel
Shaul Mukamel
NGNien-Hui Ge
Nien-Hui Ge
We have investigated the sensitivity of two-dimensional infrared (2D IR) spectroscopy to peptide helicity with an experimental and theoretical study of Z-[l-(αMe)Val]8-OtBu in CDCl3. 2D IR experiments were carried out in the amide-I region under the parallel and the double-crossed polarization configurations. In the latter polarization configuration, the 2D spectra taken with the rephasing and nonrephasing pulse sequences exhibit a doublet feature and a single peak, respectively. These cross-peak patterns are highly sensitive to the underlying peptide structure. Spectral calculations were performed on the basis of a vibrational exciton model, with the local mode frequencies and couplings calculated from snapshots of molecular dynamics (MD) simulation trajectories using six different models for the Hamiltonian. Conformationally variant segments of the MD trajectory, while reproducing the main features of the experimental spectra, are characterized by extraneous features, suggesting that the structural ensembles sampled by the simulation are too broad. By imposing periodic restraints on the peptide dihedral angles with the crystal structure as a reference, much better agreement between the measured and the calculated spectra was achieved. The result indicates that the structure of Z-[l-(αMe)Val]8-OtBu in CDCl3 is a fully developed 310-helix with only a small fraction of α-helical or nonhelical conformations in the middle of the peptide. Of the four different combinations of pulse sequences and polarization configurations, the nonrephasing double-crossed polarization 2D IR spectrum exhibits the highest sensitivity in detecting conformational variation. Of the six local mode frequency models tested, the electrostatic maps of Mukamel and Cho perform the best. Our results show that the high sensitivity of 2D IR spectroscopy can provide a useful basis for developing methods to improve the sampling accuracy of force fields and for characterizing the relative merits of the different protocols for the Hamiltonian calculation.

30 July 2009 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
HMHiroaki Maekawa
Hiroaki Maekawa
MPMatteo De Poli
Matteo De Poli
Alessandro MorettoAlessandro Moretto
Alessandro Moretto
CTClaudio Toniolo
Claudio Toniolo
NGNien-Hui Ge
Nien-Hui Ge

9 July 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
YFYuan Feng
Yuan Feng
IVIlya Vinogradov
Ilya Vinogradov
NGNien-Hui Ge
Nien-Hui Ge
In this work, we optimize and further advance a noise reduction scheme for heterodyne spectroscopy. This scheme linearly combines data from reference detectors to predict the noise statistics in the signal detector through an optimized coefficient matrix. We validate this scheme for visible white-light-continuum and 800-nm light sources using un-matched CMOS arrays and show that the signal-to-noise ratio can approach the noise floor of the signal detector while using only ~5% of the energy for reference detection. We also optimize the strategy for estimating the coefficient matrix in practical applications. When combined with elaborate algorithms to perform pixel data compression and expansion, our scheme is applicable in difficult situations, including when the sample position is rapidly scanned, when detectors exhibit nonlinear response, and/or when laser fluctuations are large. The scheme is generalized to scenarios with complex chopping or phase cycling patterns, and a simple approach is provided for the chopping case. Finally, a robust and computationally efficient method is devised to remove multiplicative noise.