Yoo-Mi Kim

Yoo-Mi Kim

Auto-generated profile, based on publicly available information

Yoo-Mi Kim

Korea Hlth Informat Serv, Elect Med Records Syst Certificat Criteria Dev Dep, Seoul, South Korea

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GJGyeong-Suk Jeon
Gyeong-Suk Jeon
SYSun-Ju You
Sun-Ju You
MKMyo-Gyeong Kim
Myo-Gyeong Kim
YKYoo-Mi Kim
Yoo-Mi Kim
SCSung-Il Cho
Sung-Il Cho
Despite the increasing number of homecare workers, a reliable and valid tool with which to measure burnout among Korean homecare workers is still lacking. The aim of this study was to examine the reliability and construct validity of the Korean version of the Copenhagen Burnout Inventory (CBI-K). The study population consisted of 465 homecare workers. Data were collected in 2016 through a self-administered questionnaire including the three subscales of the CBI-K, the Center for Epidemiologic Studies Depression Scale (CESD-10), a measure of work–life conflict, and questions about respondents’ sociodemographic characteristics. The confirmatory factor analyses results showed that the model fit indices of the refined three-factor model, in which the PB, WRB, and CRB subscales each contained six items, were acceptable (CFI = 0.924, SRMR = 0.049, RMSEA = 0.091). Furthermore, based on the results for construct reliability, discriminant validity of the refined three-factor model and job characteristics of homecare workers, we proposed that an abbreviated two-factor scale using the PB and CRB subscales could be used, with appropriate model fit indices (CFI = 0.950, SRMR = 0.047, RMSEA = 0.084). Each of the PB, WRB, and CRB subscales of CBI-K were associated with depressive symptoms even after controlling for covariates. The CBI-K has adequate reliability and validity for use with homecare workers. To increase its practicality, we suggest a refined form comprising only PB and CRB subscales can be used rather than a three-factor model.

9 November 2022 in JMIR Medical Informatics
Verified
Journal Article
Open access
SJSungwon Jung
Sungwon Jung
SBSungchul Bae
Sungchul Bae
DSDonghyeong Seong
Donghyeong Seong
OOOck Hee Oh
Ock Hee Oh
YKYoomi Kim
Yoomi Kim
BYByoung-Kee Yi
Byoung-Kee Yi
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Clinical decision support (CDS) can improve healthcare with respect to the quality of care, patient safety, efficiency, and effectiveness. Establishing a CDS system in a healthcare setting remains a challenge. A few hospitals have used self-developed in-house CDS systems or commercial CDS solutions. Since these in-house CDS system tends to be tightly coupled with a specific EHR system, the functionality and knowledge base are not easily shared. A shared interoperable CDS system facilitates sharing knowledge base and extension of CDS services. Objective: The study focuses on developing and deploying the national CDS service for the drug-allergy interaction (DAI) check for healthcare providers that need to introduce the service but lack budget and expertise in Korea. Methods: To provide the shared interoperable CDS service, we designed and implemented the system based on the CDS Hooks® specification and HL7® (Health Level 7) FHIR® (Fast Healthcare Interoperability Resources) standard. The study describes the CDS development process. The system development went through the requirement analysis, design, implementation, and deployment. In particular, the concept architecture was designed based on the CDS Hooks structure. The MedicationRequest and AllergyIntolerance resources were profiled to exchange data using the FHIR standard. The discovery and DAI check APIs and rule engine were developed. Results: The CDS service was deployed on G-Cloud, a government cloud service. In March 2021, the CDS service was launched, and 67 healthcare providers participated in the CDS service. The healthcare providers participated in the service with 1,008,357 DAI checks for 114,694 patients, of which 33,054 cases resulted in a "warning" (3.32%). Conclusions: Korea's Ministry of Health and Welfare has been trying to build an HL7 FHIR-based ecosystem in Korea. As one of these efforts, the CDS service initiative has been conducted. To promote the rapid adoption of the HL7 FHIR standard, it is necessary to accelerate the practical service development and appeal the benefits of FHIR standardization to policymakers. With the development of various case-specific implementation guides (IGs) using the KR Core IG, the FHIR standards will be distributed nationwide, and more shared interoperable healthcare services will be introduced in Korea.

1 January 2019 in Korean Journal of Adult Nursing
Verified
Journal Article
Open access
MKMyo-Gyeong Kim
Myo-Gyeong Kim
SYSun-Ju You
Sun-Ju You
GJGyeong-Suk Jeon
Gyeong-Suk Jeon
YKYoo-Mi Kim
Yoo-Mi Kim

4 November 2026 in JMIR Medical Informatics
Verified
Journal Article
Open access
JCjoohyun chung
joohyun chung
YPYe-Eun Park
Ye-Eun Park
YKYoomi Kim
Yoomi Kim
JLJae-Ho Lee
Jae-Ho Lee
YLYura Lee
Yura Lee
Background: Electronic medical record (EMR) certification programs have traditionally focused on product-level requirements, such as interoperability, security, and core functionality. However, growing evidence suggests that many patient safety risks associated with EMRs arise after implementation and are closely related to system configuration, workflow integration, and real-world use. Despite the presence of a national EMR product certification system in Korea, a systematic evaluation of how certified systems are implemented and used in clinical practice is still lacking. Objective: This study aimed to develop and validate a self-assessment checklist for EMR use certification, focused on patient safety-critical functions, and to evaluate its content validity and expert-assessed practical applicability across health care institutions of different sizes. Methods: A convergent mixed methods design was used. A self-assessment checklist comprising 10 patient safety–related EMR functions was developed by adapting the US Office of the National Coordinator for Health Information Technology self-assessment templates to the Korean EMR certification context. Content validity was quantitatively assessed using the Content Validity Index across 4 dimensions (relevance, usefulness, clarity, and importance) by a panel of 24 experts with experience in EMR implementation and certification. Qualitative feedback was collected through open-ended survey questions to examine feasibility, anticipated challenges, and differentiation between product and use certification across tertiary referral hospitals, general hospitals, and clinics. Results: The overall Scale-Level Content Validity Index was 0.921, indicating strong content validity for the proposed checklist. Although most items demonstrated high agreement, lower ratings were observed for certain functions, particularly in clinic-level settings, reflecting structural and resource-related constraints rather than limited recognition of patient safety priorities. Qualitative findings highlighted challenges related to staffing, system governance, and the feasibility of assembling multidisciplinary assessment teams in smaller institutions. Conclusions: The self-assessment checklist demonstrated high content validity and was perceived as relevant for evaluating patient safety–critical aspects of EMR use. However, expert-assessed feasibility varied across health care institution types, particularly in clinic-level settings. Further empirical testing is needed to assess the checklist’s reliability, usability, and applicability in real-world certification processes.