Periyadi Periyadi

Periyadi Periyadi

Auto-generated profile, based on publicly available information

Periyadi Periyadi

Technology Computer Program Study, Department of Applied Sciences, Telkom University, Bandung 40257, Indonesia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2025 in Journal of Electronics, Electromedical Engineering, and Medical Informatics
Verified
Journal Article
Open access
GMGiva Andriana Mutiara
Giva Andriana Mutiara
HAHardy Adiluhung
Hardy Adiluhung
PPPeriyadi Periyadi
Periyadi Periyadi
MAMuhammad Rizqy Alfarisi
Muhammad Rizqy Alfarisi
LMLisda Meisaroh
Lisda Meisaroh
Ergonomic stress inside armored military vehicles presents a critical yet often overlooked risk to soldier safety, operational effectiveness, and long-term health. Traditional ergonomic assessments rely heavily on subjective expert evaluations, failing to capture dynamic environmental stressors such as vibration, noise, thermal fluctuations, and gas exposure during actual field operations. This study aims to address this gap by introducing the Biomechanical Human Model Interface (BHMI), a multi-sensor platform designed to objectively quantify ergonomic stress under operational conditions. The main contribution of this work is the development and validation of BHMI, which integrates anthropometric human modeling with embedded environmental sensors, enabling real-time, multi-dimensional ergonomic data acquisition during vehicle maneuvers. BHMI was deployed in high-speed off-road vehicle operations, simulating the 50th percentile Indonesian soldier seated posture. The system continuously monitored vibration (0–16 g range), noise (30–130 dB range), temperature (–40°C to 80°C), humidity (0–100% RH), and gas concentrations (CO and NH₃) using calibrated, field-hardened sensors. Experimental results revealed ergonomic stress levels exceeding human tolerance thresholds, including vibration peaks reaching 9.8 m/s², cabin noise levels up to 100 dB, and cabin temperatures exceeding 39°C. The use of BHMI improved the repeatability and precision of ergonomic risk assessment by 27% compared to traditional methods. Seating gap deviations of up to ±270 mm was identified when soldiers wore full operational gear, highlighting critical areas of postural fatigue risk. In conclusion, BHMI represents a novel, sensor-integrated approach to ergonomic evaluation in military environments, enabling more accurate design validation, reducing subjective bias, and providing actionable insights to enhance soldier endurance, comfort, and mission readiness.

9 January 2025 in Journal of Electrical and Electronic Engineering
Verified
Journal Article
Open access
PDF file
GMGiva Andriana Mutiara
Giva Andriana Mutiara
PMPeriyadi Mutiara
Periyadi Mutiara
MAMuhammad Rizqy Alfarisi
Muhammad Rizqy Alfarisi
LMLisda Meisaroh
Lisda Meisaroh
Laboratory mice (Mus musculus) play a crucial role in scientific research, where accurate classification and sorting are essential for ensuring reliable experimental results. This study presents an intelligent multi-sensor system for the automated classification and sorting of laboratory mice based on three key parameters: health status, gender, and weight. The system integrates thermal imaging cameras AMG8833 for monitoring the health status of mice, object detection algorithms (YOLOv8) for gender classification, and load cell HX711 sensors for weight measurement. The integration of these sensors leverages advanced sensor fusion techniques to improve classification accuracy and efficiency. Thermal imaging detects physiological anomalies to assess the health condition of the mice, while object detection algorithms identify gender characteristics in real-time with high precision. Additionally, load cell sensors provide accurate weight data for further categorization. The combined system eliminates the need for manual intervention, ensuring a non-invasive, efficient, and scalable approach to laboratory animal management. The proposed system performed evaluation through multiple test scenarios aimed at assessing the health of mice and classifying their weight. The detection of mice gender was evaluated using a dataset comprising over 6,722 images stored in the STASRG laboratory. The test results indicated that the accuracy of animal sorting across three parameters achieved a 100% success rate. The accuracy of gender sorting was 86.67%, while the accuracy of weight measurement exhibited a difference of approximately 0.1 gram. The overall response time for sorting was 19 seconds. This multi-sensor integration demonstrates the potential to enhance laboratory workflows, minimize human error, and promote the welfare of laboratory animals via automated, data-driven processes.

14 August 2017 in IJAIT (International Journal of Applied Information Technology)
Verified
Journal Article
Open access
PDF file
AHAndi Harits
Andi Harits
MRMochammad Fahru Rizal
Mochammad Fahru Rizal
PPPeriyadi Periyadi
Periyadi Periyadi
Enterprise networks. This research focuses on combining advantages from Frame Relay, MPLS and OSPF into a modeled multi-site network. The combination is compared to th original OSPF network and analyzed for its throughput, packet loss, and delay. To meet the demand for efficient and resilient network, and to emphasize the advantages of MPLS-OSP as well as to avoid traffic shifting, specific network topology models are applied: full mesh with virtual circuit in core network connected to OSPF nodes for the rest. From analysis and comparison of network quality values obtained at, this combination attests to be reliable and robust network architecture without trading off its efficiency. The average throughput value of the combination networks was 18.47 bps, which is better compared to the OSPF. The average delay and packet loss from combination network also show better results, which are 59.90ms and 2.01% respectively. The results shows that the combination of Frame Relay, OSPF andMPLS generates better performance as well as significant improvement in networksecurity.

24 March 2026 in Applied System Innovation
Verified
Journal Article
Open access
PDF file
GMGiva Andriana Mutiara
Giva Andriana Mutiara
MAMuhammad Rizqy Alfarisi
Muhammad Rizqy Alfarisi
PMParamita Mayadewi
Paramita Mayadewi
LMLisda Meisaroh
Lisda Meisaroh
PEPeriyadi
Periyadi
Continuous monitoring of sitting posture is crucial for ergonomic assessment and fatigue prevention, yet many existing approaches rely on vision-based systems or single-modality sensing that are limited in capturing spatial and temporal biomechanical dynamics. This paper presents a multimodal smart-skin sensing system for spatial and temporal ergonomic fatigue analysis in sitting postures. The proposed platform integrates 42 distributed pressure, temperature, and vibration sensors arranged in 14 trimodal sensing nodes embedded across anatomical seating and back regions to enable real-time multimodal acquisition of human–chair interaction patterns. The study introduces an analytical framework combining anatomical heatmap visualization, temporal evolution analysis, delta pressure mapping, fatigue intensity estimation, and hotspot detection to characterize dynamic pressure redistribution during prolonged sitting. Experimental evaluations were conducted using a biomechanical mannequin and a single human participant with identical anthropometric characteristics (165 cm height and 62 kg body mass) across nine seated conditions, including neutral sitting, reclining, leaning, periodic shifting, and vibration-induced motion. Each posture condition was recorded as a time-series session and segmented into temporal phases to analyze fatigue evolution during prolonged sitting. Statistical analysis of pressure redistribution dynamics indicates significantly higher pressure drift in human measurements compared with the mechanically stable mannequin baseline (p < 0.001). The proposed framework provides a scalable sensing approach for ergonomic monitoring, intelligent seating systems, and human–machine interface applications.

Verified
Journal Article
Open access
PDF file
GMGiva Andriana Mutiara
Giva Andriana Mutiara
MAMuhammad Rizqy Alfarisi
Muhammad Rizqy Alfarisi
PMParamita Mayadewi
Paramita Mayadewi
LMLisda Meisaroh
Lisda Meisaroh
PEPeriyadi
Periyadi
Prolonged sitting with poor posture is associated with musculoskeletal disorders, reduced productivity, and long-term health risks. Many existing posture monitoring systems predominantly rely on single-modality sensing, such as pressure or vision-based approaches, limiting their ability to capture both static alignment and dynamic micro-movements. This study proposes a multimodal smart-skin system integrating pressure, temperature, and vibration sensors for sitting posture recognition. A total of 42 sensors distributed across 14 anatomical locations were deployed, generating 15,037 samples collected over three independent sessions to evaluate cross-session temporal generalization across nine posture classes under controlled experimental conditions. Two deep learning architectures—Temporal Convolutional Networks with Attention (TCN + Attn) and Convolutional Neural Network–Long Short-Term Memory (CNN − LSTM)—were compared under Leave-One-Session-Out (LOSO) cross-validation. TCN + Attn achieved 85.23% LOSO accuracy, outperforming CNN − LSTM by 2.56 percentage points while reducing training time by 36.7% and inference latency by 33.9%. Ablation analysis revealed that temperature sensing was the most discriminative unimodal modality (71.5% accuracy), and full multimodal fusion improved LOSO accuracy by 22.93% compared to pressure-only configurations. These results demonstrate the feasibility of multimodal smart-skin sensing combined with temporal convolutional modeling for cross-session posture recognition and indicate potential for efficient real-time, privacy-preserving ergonomic monitoring. This study should be interpreted as a controlled, single-subject proof-of-concept, and further validation in multi-subject and real-world environments is required to establish broader generalizability.