Slimane Semghouli

Slimane Semghouli

Auto-generated profile, based on publicly available information

Slimane Semghouli

Higher Institute of Nursing Professions and Health Techniques, Agadir, Morocco

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Radioprotection
Verified
Journal Article
Open access
PDF file
MFMohamed EL Fahssi
Mohamed EL Fahssi
SSSlimane Semghouli
Slimane Semghouli
BABouchra Amaoui
Bouchra Amaoui
LJLaila Jroundi
Laila Jroundi
MCMalika Çaoui
Malika Çaoui
Objective: This study aimed to assess patient radiation doses, and to establish diagnostic reference levels for Adult CT examinations at the Souss Massa Regional Hospital, Morocco. Method: Data from 6 CT examinations were collected between January and June 2023 at the Souss Massa Regional Hospital, including patient age, sex, weight, and height, as well as scanner acquisition parameters such as the number of series, use of contrast media, rotation time plus slice thickness, the displayed Computed Tomography Dose Index (CTDIvol), and the Dose Length Product (DLP). Diagnostic reference levels (DRLs) were calculated for each type of CT examination by estimating the 75% percentile of CTDIvol and DLP. The effective dose is calculated using the following formula: E(mSv) = EDLP × DLP (mGy.cm). The data were statistically analyzed using SPSS version 21.0 software. Results: DRLs in terms of CTDIvol, and DLP for the brain without contrast media are 64,45 mGy, and 1405,77 mGy.cm respectively. For chest CT without contrast media, they are 11,13 mGy, and 417,73 mGy.cm respectively. The data from the abdominal CT show that the CTDIvol (9,74 mGy) and DLP (529,31 mGy.cm) values with contrast media are higher than those without contrast media, which are (9,35 mGy) and (515,21 mGy.cm) respectively. DRls in terms of CTDIvol and DLP for abdomen and pelvis (AP) CT with contrast media are 8,14 mGy and 444,51 mGy.cm respectively. For chest abdomen and pelvis (CAP) with contrast media they are 8,51 mGy, and 571,30 mGy.cm respectively. The effective doses were 2,37, 6,50, 6,24, 6,76, 5,07, 7,13 mSv for the brain without contrast media, chest without contrast media, abdomen without contrast media, abdomen with contrast media, AP with contrast media, and CAP respectively. Conclusion: Adapting CT protocols according to the morphology of patients and the conditions under which each examination is performed can help maintain the doses received by patients at an optimum level.

29 June 2019 in Perspectives in Science
Verified
Journal Article
Open access
PDF file
SSSlimane Semghouli
Slimane Semghouli
BABouchra Amaoui
Bouchra Amaoui
AKAbdennasser El Kharras
Abdennasser El Kharras
KBKhalid Bouykhlaf
Khalid Bouykhlaf
OHOum Keltoum Hakam
Oum Keltoum Hakam
ACAbdelmajid Choukri
Abdelmajid Choukri
The purpose of this study is to evaluate the patients’ radiation dose in three different modalities of CT scanners (64, 16 and 2 slices) and the biological effects during CT brain examinations. A total of 60 patients were examined in three different hospitals in Morocco. The data were collected from CT Brain examinations at of 20 CT scans per hospital. For each examination, we have reported CT acquisition parameters including the number of series, use of contrast medium; tube kV, tube current and rotation time, slice thickness as well as the displayed CT dose index (CTDIvol) and the Dose Length Product (DLP). Cancer and biological heredity risks were estimated using the International Commission on Radiological Protection (ICRP) conversion factors. The average dose values for CT brain for 2 slices was 305 ± 112 mGy.cm. The mean dose value for 16 slices was 716 ± 179mGy.cm, while the average dose for 64 slices was 1136± 708 mGy.cm. The patient cancer risks per procedure ranged between 4 and 13 per 105 CT procedures. This risk is 4, 8 and 13 per 105 CT procedures for 2 slices, 16 slices and 64 slices respectively. The patient heredity risks varied between 1 and 5 per million CT procedures. It is 1, 3 and 5 for 2 slices, 16 slices and 64 slices respectively. Dual slice scanner delivered the least effective dose while 16 and 64 slice scanners delivered the highest effective dose. The dose values of this study were comparable to the international reference levels of CT examination. CT dose optimisation protocol is not implemented in the Moroccan hospitals. These values could be used as our hospital's Dose Reference Levels (DRL) until a more detailed study survey can be conducted in Morocco for the establishment of the country's reference levels.

1 April 2023 in Radioprotection
Verified
Journal Article
Closed access
PDF file
MFM. El Fahssi
M. El Fahssi
SSS. Semghouli
S. Semghouli
BAB. Amaoui
B. Amaoui
LJL. Jroundi
L. Jroundi
MCM. ÇaOui
M. ÇaOui
The objective of this study is to evaluate the Entrance Skin Dose (ESD), and to establish the Diagnostic Reference Levels (DRLs) for the most common X-ray examinations in adult patients in the Souss-Massa region of Morocco. Data from 720 adult patients in four radiology departments in the Souss-Massa region were collected. The data concerned the following examinations: thorax posterior anterior (PA), unprepared abdominal X-ray, pelvis, hip, cervical spine anterior-posterior (AP) and lateral (Lat), lumbar spine anterior-posterior (AP) and lateral (Lat). The following parameters were reported for each examination: age, weight, patient thickness, voltage (kV), electrical charge (mAs), and the skin source distance. The Entrance Skin Dose and the Diagnostic Reference Levels are calculated for each X-ray examination. DRLs in terms of ESD for the same X-ray examination differ widely from one hospital to another. They ranged from 3 to 14 mGy for the unprepared abdominal X-ray, from 2.6 to 9.4 mGy for the pelvis, from 3.1 to 17 mGy for the hip, from 1 to 49.2 mGy for the cervical spine Lat, from 2 to 32.6 mGy for the lumbar spine AP, and from 18.1 to 50 mGy for the lumbar spine Lat. The variation of doses received by patients in the four hospitals calls into question radiological procedures and practices and calls for a standardization of guidelines for each radiological examination.

1 July 2024 in Radioprotection
Verified
Journal Article
Open access
PDF file
MFM. El Fahssi
M. El Fahssi
SSS. Semghouli
S. Semghouli
BAB. Amaoui
B. Amaoui
JEJaouad Elkhalladi
Jaouad Elkhalladi
MCM. Çaoui
M. Çaoui
LJL. Jroundi
L. Jroundi
Introduction: Radiographers play a vital role in patient radiation protection. Their training, supervision, and involvement in radiation protection programmes require greater attention from all stakeholders. Methods: This cross-sectional study was conducted between March and August 2023 to assess Radiographers’ attitudes toward the principles of patient radiation protection in the Souss Massa region of Morocco. An anonymous questionnaire containing 22 questions was sent to 80 radiographers practicing in the Sous Massa region. Results: 67.5% of the radiographers confirmed that they did not use a guide to radiological procedures. 85% of them confirmed that they had checked for the possibility of pregnancy each time a woman of childbearing age was involved in a conventional X-ray, compared with 97.5% who checked for the possibility of pregnancy in a CT scan. 97.5 % of our participants said that they automatically (without medical advice) repeated the X-ray examination if the image was not interpretable. 90% of radiographers said that they did not report parameters for dose estimation for each conventional X-ray examination, and 72.5% did not report data for dose estimation for CT-scan examinations. The results showed no association between gender and professional experience on the one hand and radiographers’ practices on the other. Nevertheless, there is an association between the workplace and certain radiographers’ practices, indicating the lack of a regional strategy aimed at standardizing procedures and radiation protection practices at the level of all radiology departments. Conclusion: It is vital to launch a patient dose management program in the Souss Massa region and campaigns to raise radiographers’ awareness of recommended patient radiation protection practices.

31 December 2021 in Pan African Medical Journal
Verified
Journal Article
Open access
SSSlimane Semghouli
Slimane Semghouli
BABouchra Amaoui
Bouchra Amaoui
SWSoukaina Wakrim
Soukaina Wakrim
INTRODUCTION: The aim of this study was to establish local Diagnostic Reference Levels (DRLs) for four adult Computed Tomography (CT) examinations in the radiology department, Hassan II hospital of Agadir.

1 January 2024 in Radioprotection
Verified
Journal Article
Open access
PDF file
SSS. Semghouli
S. Semghouli
LHL. El Hamidi
L. El Hamidi
MAM. Aabid
M. Aabid
BAB. Amaoui
B. Amaoui
Objective: In this study, we have planned to establish the local Diagnostic Reference Levels (DRLs) for the five University Hospital Centers in Morocco and to propose a national DRL for abdominopelvic CT examinations for adult patients. Materials and methods: Data were collected using a specially designed form, which included patient demographics, exposure parameters and dosimetric indicators such as dose-length product (DLP) and CT volume dose index (CTDIvol). The establishment of local and national DRL in terms of CTDIvol and DLP was carried out in accordance with the methodology described in Report 135 of the International Commission on Radiological Protection (ICRP). The effective dose was assessed using the DLP and the dose conversion factor appropriate for this location. Results: A total of 300 patients undergoing abdominopelvic examinations at the five Moroccan university hospitals were collected for this study. Patients' mean age, weight and BMI were (50.97 ± 15.05) years (67.94 ± 11.41) Kg and (25.71 ± 3.03) Kg/m2 respectively. The local DRL, in terms of DLP were 551.56, 2293.33, 709.02, 843.52 and 1059.62 mGy-cm and in terms of CTDIvol were 11,05, 46,40, 13,14, 12,01, 9,88 mGy respectively for UHC-1, UHC-2, UHC-3, UHC-4 and UHC-5 hospitals. The proposed National DRL, defined as a single value for the 75th percentile on the aggregation of data from the five centers, for abdominopelvic scan CT was 773.20 mGy.cm and 12.05 mGy for DLP and CTDIvol, respectively. Conclusion: The Moroccan DRL was comparable to those of other countries, ranking 10th among 21 countries. However, we are still seeking to reduce and optimize radiation dose while maintaining good image quality for reliable diagnosis, and this can be achieved by enhancing radiographers' and radiologists' knowledge of radiation protection, protocol justification, and optimization through rigorous hospital radiation audits at national level.