1 January 2020 in Journal of Bridge Engineering
Visual inspection is the primary means of ensuring the safety and functionality of in-service bridges in the United States and owners spend considerable resources on such inspections. While the Federal Highway Administration (FHWA) and many state departments of transportation have guidelines related to inspector qualification, training, and certification, an inspector’s actual capability to identify defects in the field under these guidelines is unknown. This paper describes the results from 30 hands-on, visual inspections performed on bridge specimens with known fatigue cracks. Background information was collected on each inspector and correlated with inspection performance. Field temperature, duration, experience, and training were significantly correlated with detection rate. Probability of detection (POD) curves were fit to the inspection results and the 50% and 90% detection rate crack lengths were determined. This POD study was conducted to provide a benchmark measure of visual inspection capability for detecting fatigue cracks in steel bridge components under controlled conditions. It is believed to be the first study in which a statistically significant set of data focused on visual detection of fatigue cracks in steel bridge components has been collected.
23 June 2014 in Research in Nondestructive Evaluation
A significant form of deterioration in concrete is corrosion of embedded reinforcing steel that can cause subsurface delaminations and spalling. Infrared thermography can be used to detect delaminations based on variations in surface temperature that are caused by the disruption of the heat flow through the delaminated area. The surrounding environmental conditions such as sunlight, ambient temperature variation, and wind speed are critical for heat transfer, and as such the technology depends on these environmental conditions. This paper describes a numerical model developed to predict thermal contrasts for subsurface delaminations based on a given set of environmental conditions surrounding the concrete. The finite element method (FEM) was used to perform 3-D nonlinear transient heat-transfer analysis of a large concrete block with embedded Styrofoam targets intended to provide an idealized model of subsurface delaminations. The effectiveness of the modeling was evaluated by comparing the thermal contrasts predicted by the model and those obtained from experimental testing of an actual concrete block of the same dimensions. The correlation and error between the experimental testing and the model results indicated that the model could be an effective tool for the prediction of anticipated thermal contrasts based on given weather conditions.
1 April 2016 in Journal of Bridge Engineering
This paper presents a new methodology for determining bridge inspection intervals and procedures. The methodology was developed using established risk-based methodologies with the goals of improving bridge safety and serviceability and optimizing the use of resources for bridge inspection. Current inspection intervals are calendar based and generally require routine inspections at a maximum interval of 24 months. This uniform, calendar-based approach results in the same inspection interval for new bridges and aging and deteriorated bridges. The uniform inspection interval does not consider the inspection needs for a given bridge based on age, condition, materials, environment, etc., and as a result, inspection resources may not be utilized most effectively. Using the methodology described in this paper, a bridge owner performs a simple risk-based assessment of bridges in his or her inventory to identify those for which shorter inspection intervals are needed and those for which longer intervals a...
1 January 2010 in Transportation Research Record: Journal of the Transportation Research Board
The deterioration of concrete bridge components due to corrosion presents a significant challenge for bridge owners worldwide. Deterioration commonly develops at the level of embedded reinforcing steel because of the expansion of corrosion products and resulting stresses in the concrete. As a result, deterioration cannot be detected with visual inspection until it has progressed sufficiently to be manifest in spalling or advanced deterioration of the concrete. This paper presents the results of a study to develop thermal imaging (infrared imaging) for detection of subsurface deterioration. This nondestructive evaluation technique detects delamination on the basis of resulting perturbations in the heat transfer characteristics of the concrete, which are manifest as variations in surface temperature. The technique has the advantage of being applied from a distance and thus reduces access and traffic control requirements. However, it depends on certain environmental conditions to achieve thermal gradients in the concrete needed to detect subsurface deterioration. This study explored the effects of environmental parameters on the detectability of delamination in concrete. Specifically, the effects of diurnal temperature changes on the detection of damage in the soffit area of bridges are reported. Experimental studies and field testing were conducted. This paper focuses on guideline requirements developed through the research for the effective application of the technology in the field and describes experience with application of the technology for the detection of deterioration in a typical highway bridge.
1 February 2018 in Journal of Bridge Engineering
This article reports on research to experimentally analyze the reliability of ground-coupled ground-penetrating radar (GPR) for the detection and imaging of subsurface delamination in concrete. Experimental studies were conducted that included a RC deck mock-up with synthetic delamination targets and two highway bridge decks. Both of the bridge decks had areas of delamination as determined through sounding, infrared thermography, and some limited physical sampling. Receiver operating characteristics (ROC) analysis was used to evaluate the reliability of GPR when implemented using the procedure described in the current ASTM standard that employs signal reflections from uppermost steel bars. The overall results indicate that GPR had limited ability to detect and image areas of delamination in concrete using the aforementioned ASTM procedure. After almost four decades of implementation of GPR for the condition assessment of concrete bridge decks, confusion remains regarding the ability of GPR to directly detect areas of delamination. The findings from this research should make an important contribution to clarifying this issue to improve decision making for maintenance and repair when considering GPR as a condition assessment tool.
4 August 2008 in Research in Nondestructive Evaluation
This article presents the results of an investigation of the Raman scattering effects of aging Kevlar strands. The goal of this research was to investigate the potential application of Raman spectroscopy as a nondestructive evaluation tool for the detection of aging effects of in-service composite materials. Kevlar composites used as overwrapping of metal-lined composite overwrapped pressure vessels (COPVs) have been analyzed. Raman spectra produced from the Kevlar fibers and the effects of resin materials, utilized to bind the fibers into strands to provide composite behavior, have been investigated. A series of Kevlar/epoxy strands exposed to elevated temperatures and sustained loading have been evaluated. It was found that this exposure had an effect on the width and intensity of certain bands in the Raman spectra of Kevlar. The potential application of these findings to the nondestructive evaluation of Kevlar composites is discussed.