18 December 2015 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
In this paper, the performance of the phase space representation in interpreting the underlying dynamics of epileptic seizures is investigated and a novel patient-specific seizure detection approach is proposed based on the dynamics of EEG signals. To accomplish this, the trajectories of seizure and nonseizure segments are reconstructed in a high dimensional space using time-delay embedding method. Afterwards, Principal Component Analysis (PCA) was used in order to reduce the dimension of the reconstructed phase spaces. The geometry of the trajectories in the lower dimensions is then characterized using Poincaré section and seven features were extracted from the obtained intersection sequence. Once the features are formed, they are fed into a two-layer classification scheme, comprising the Linear Discriminant Analysis (LDA) and Naive Bayesian classifiers. The performance of the proposed method is then evaluated over the CHB-MIT benchmark database and the proposed approach achieved 88.27% sensitivity and 93.21% specificity on average with 25% training data. Finally, we perform comparative performance evaluations against the state-of-the-art methods in this domain which demonstrate the superiority of the proposed method.
14 September 2016 in Computing in cardiology
1 June 2014 in Journal of Biomedical Informatics
27 March 2019 in IEEE Journal of Biomedical and Health Informatics
Nonlinear dynamics has recently been extensively used to study epilepsy due to the complex nature of the neuronal systems. This study presents a novel method that characterizes the dynamic behavior of pediatric seizure events and introduces a systematic approach to locate the nullclines on the phase space when the governing differential equations are unknown. Nullclines represent the locus of points in the solution space where the components of the velocity vectors are zero. A simulation study over 5 benchmark nonlinear systems with well-known differential equations in 3D exhibits the characterization efficiency and accuracy of the proposed approach that is solely based on the reconstructed solution trajectory. Due to their unique characteristics in the nonlinear dynamics of epilepsy, discriminative features can be extracted based on the nullclines concept. Using a limited training data (only 25% of each EEG record) in order to mimic the real-world clinical practice, the proposed approach achieves 91.15% average sensitivity and 95.16% average specificity over the benchmark CHB-MIT dataset. Together with an elegant computational efficiency, the proposed approach can, therefore, be an automatic and reliable solution for patient-specific seizure detection in long EEG recordings.
17 November 2020 in IEEE Access
Echocardiogram (echo) is the earliest and the primary tool for identifying regional wall motion abnormalities (RWMA) in order to diagnose myocardial infarction (MI) or commonly known as heart attack. This paper proposes a novel approach, Active Polynomial, which can accurately and robustly estimate the global motion of the Left Ventricular (LV) wall from any echo in a robust and accurate way. The proposed algorithm quantifies the true wall motion occurring in LV wall segments so as to assist cardiologists diagnose early signs of an acute MI. It further enables medical experts to gain an enhanced visualization capability of echo images through color-coded segments along with their “maximum motion displacement“ plots helping them to better assess wall motion and LV Ejection-Fraction (LVEF). The outputs of the method can further help echo-technicians to assess and improve the quality of the echocardiogram recording. A major contribution of this study is the first public echo database collection composed by physicians at the Hamad Medical Corporation Hospital in Qatar. The so-called HMC-QU database will serve as the benchmark for the forthcoming relevant studies. The results over HMC-QU dataset show that the proposed approach can achieve 87.94% accuracy, 92.86% sensitivity and 87.64% precision in MI detection even though the echo quality is quite poor and the temporal resolution is low.