Jaime Flores-Estrada

Jaime Flores-Estrada

Auto-generated profile, based on publicly available information

Jaime Flores-Estrada

Facultad de Química, Universidad Autónoma del Estado de México, Toluca, México

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2016 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
AEAlondra Escudero-Castellanos
Alondra Escudero-Castellanos
Blanca Ocampo-GarcíaBlanca Ocampo-García
Blanca Ocampo-García
MDMa. Victoria Domínguez-García
Ma. Victoria Domínguez-García
JFJaime Flores-Estrada
Jaime Flores-Estrada
MFMiriam V. Flores-Merino
Miriam V. Flores-Merino

1 October 2012 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
UVUlises Velázquez-Enríquez
Ulises Velázquez-Enríquez
RSRogelio J Scougall-Vilchis
Rogelio J Scougall-Vilchis
RCRosalia Contreras-Bulnes
Rosalia Contreras-Bulnes
JFJaime Flores-Estrada
Jaime Flores-Estrada
SUShinsuke Uematsu
Shinsuke Uematsu
RYRyozo Yamaguchi
Ryozo Yamaguchi
In orthodontics, fixed appliances placed in the oral cavity are colonized by microorganisms. The purpose of this study was to quantitatively determine the independent bacterial colonization of S. mutans and S. sobrinus in orthodontic composite resins. Seven orthodontic composite adhesives for bonding brackets were selected and classified into 14 groups; (GIm, GIs) Enlight, (GIIm, GIIs) Grengloo, (GIIIm, GIIIs) Kurasper F, (GIVm, GIVs) BeautyOrtho Bond, (GVm, GVs) Transbond CC, (GVIm, GVIs) Turbo Bond II, (GVIIm, GVIIs) Blugloo. 60 blocks of 4x4x1 mm of each orthodontic composite resin were made (total 420 blocks), and gently polished with sand-paper and ultrasonically cleaned. S. mutans and S. sobrinus were independently cultivated. For the quantitative analysis, a radioactive marker was used to codify the bacteria (³H) adhered to the surface of the materials. The blocks were submerged in a solution with microorganisms previously radiolabeled and separated (210 blocks for S. mutans and 210 blocks for S. sobrinus) for 2 hours at 37 ºC. Next, the blocks were placed in a combustion system, to capture the residues and measure the radiation. The statistical analysis was calculated with the ANOVA test (Sheffè post-hoc). Significant differences of bacterial adhesion were found amongst the groups. In the GIm and GIs the significant lowest scores for both microorganisms were shown; in contrast, the values of GVII for both bacteria were significantly the highest. This study showed that the orthodontic composite resin evaluated in the GIm and GIs, obtained the lowest adherence of S. mutans and S. sobrinus, which may reduce the enamel demineralization and the risk of white spot lesion formation.

4 October 2020 in International Journal of Polymeric Materials and Polymeric Biomaterials
Verified
Journal Article
Closed access
RTRocío Torres-García
Rocío Torres-García
JFJaime Flores-Estrada
Jaime Flores-Estrada
JUAN VALERIO CAUICH-RODRIGUEZJUAN VALERIO CAUICH-RODRIGUEZ
JUAN VALERIO CAUICH-RODRIGUEZ
MFMario Flores-Reyes
Mario Flores-Reyes
MFMiriam V. Flores-Merino
Miriam V. Flores-Merino
Hydrogels are three-dimensional networks with high water content become soft and elastic mimicking some characteristics of the extracellular matrix. They can be prepared by using either synthetic or natural polymers, therefore, their combination can benefit the overall of the material for a specific biomedical application. In this study, a semi-interpenetrating polymer network hydrogel of polyacrylamide/gelatin (PAM/Gel) with up to 0.3% of gelatin content was synthesized while evidence of gelatin incorporation was obtained from FTIR and Raman spectroscopy. SEM micrographs show uniform porous structure of PAM/gelatin combined hydrogels. According to the micrographs, the amount of pores decrease with the incorporation of gelatin into the PAM network. The combined hydrogel had the maximum swelling at 37 °C (1,800 ± 73%). Results indicate that PAM/Gel hydrogels are biocompatible (fibroblast viability >70%) in the presence of extracts and by direct contact method. These hydrogels can be good candidates for soft tissue engineering applications. GRAPHICAL ABSTRACT

1 January 2013 in International Journal of Polymer Science
Verified
Journal Article
Open access
PDF file
MMMaría D. Manrique-Juárez
María D. Manrique-Juárez
AMAna L. Martinez-Hernandez
Ana L. Martinez-Hernandez
OOOscar Olea-Mejia
Oscar Olea-Mejia
JFJaime Flores-Estrada
Jaime Flores-Estrada
Jose Luis Rivera-ArmentaJose Luis Rivera-Armenta
Jose Luis Rivera-Armenta
CVCarlos Velasco-Santos
Carlos Velasco-Santos
Keratin has the capacity to interact with metal ions. In order to take advantage of this potential, a novel membrane with polyurethane and keratin has been developed and studied for removal of Cr(VI) from aqueous solution. Physicochemical and morphological properties of these hybrid membranes were studied, varying synthesis parameters such as the type of isocyanate and pH in keratin solution. The effects of using diphenyl-methane-diisocyanate or toluene-diisocyanate and modifying the pH in keratin solutions were evaluated by scanning electron microscopy, Fourier transform infrared spectroscopy, and dynamical mechanical analysis. Results show that pH has a strong influence on morphology and on Cr(VI) removal efficiency. When pH in keratin solution is low (2.5), the protein separates from water, and a more closed cell in the membrane is obtained affecting its mechanical properties. The removal efficiency of Cr(VI) was also assessed at different pH values of chromium solutions. These results show that when pH of the Cr solution is acidic (at 1.5), the Cr(VI) removal percentages increase significantly, reaching up to a 58%. Thus this paper demonstrates the successful combination of synthetic and natural polymers depending on the process parameters to be applied in the critical purpose of remediation of Cr(VI) contamination.

28 November 2022 in Journal of Radiological Protection
Verified
Journal Article
Closed access
AGAbraham Gonzalez
Abraham Gonzalez
HMHelen's Irais Sánchez Mendoza
Helen's Irais Sánchez Mendoza
CSClara Leticia Santos-Cuevas
Clara Leticia Santos-Cuevas
FIFrank J Isidro-Ortega
Frank J Isidro-Ortega
JEJaime Flores Estrada
Jaime Flores Estrada
MFMiriam V. Flores-Merino
Miriam V. Flores-Merino
Quality assurance program (QAP) implementation in mammography is a key aspect to guarantee the acquisition of -quality images and, thus, an opportune diagnosis of breast cancer. A QAP involves planned and systematic actions, such as quality control (QC) tests that will produce consistently high-quality images, while considering low radiation exposure for stakeholders. Currently, there is poor evidence of the current QAP implementation status in developing countries, particularly in Latin America. In this work, 47 Mexican digital mammography facilities were evaluated in terms of their QAP implementation’s current status during the period October 2021 to April 2022. A survey of three key indicators of compliance/non-compliance with QAPs was carried out. Also, 17 QC test parameters were assessed in all mammography units according to an international framework. The Kruskal–Wallis test, McNemar test, and Spearman correlation were used to identify the significant correlation between the QC tests and QAP indicators. Statistical analysis showed a significant positive correlation between the QAP indicators and QC parameters that were evaluated, especially associated with an increase in image quality. Almost 90% of the facilities evaluated failed in some QAP indicators, and only 44.68% of the facilities had an updated and current QAP implemented. Successful QAP implementation directly impacted on the QC mammography test results, particularly in terms of image quality, thus conditioning a successful mammography acquisition chain. The results obtained in this work suggest that better regulations need to be implemented to guarantee QAP surveillance, which could mean an increase in opportune diagnosis and management of breast cancer, with improved radiological safety for patients and occupational exposure personnel.

5 February 2013 in Australian Dental Journal
Verified
Journal Article
Open access
PDF file
UVUlises Velázquez-Enríquez
Ulises Velázquez-Enríquez
RSRogelio J Scougall-Vilchis
Rogelio J Scougall-Vilchis
RCRosalia Contreras-Bulnes
Rosalia Contreras-Bulnes
JFJ Flores‐Estrada
J Flores‐Estrada
SUS Uematsu
S Uematsu
RYR Yamaguchi
R Yamaguchi
Background: This investigation aimed to determine quantitatively the adhesion of Streptococcus mutans and Streptococcus sobrinus to orthodontic composite resins that were tested simultaneously using radio‐markers.Methods: Seven orthodontic composite resins were classified into seven groups: BeautyOrtho Bond (GI), Blugloo (GII), Enlight (GIII), Grengloo (GIV), Kurasper F (GV), Transbond CC (GVI) and Turbo Bond II (GVII). Thirty 4 x 4 x 1 mm blocks of each orthodontic composite resin were made (a total of 210 blocks). Both Streptococcus species were cultivated independently. For the quantitative analysis, radioactive markers were used to codify the bacteria (3H for Streptococcus mutans and 14C for Streptococcus sobrinus). The blocks were submerged in a solution with microorganisms previously radiolabelled for 2 hours at 37 °C in constant movement. The blocks were placed in a combustion system to quantify the Streptococcus adhering to the surface of the materials by capturing the residues and measuring the radiation.Results: Significant differences in bacterial adhesion were found among the groups. The lowest significant scores for both microorganisms were observed in GIII.Conclusions: The orthodontic composite resin evaluated in GIII exhibited the lowest adhesion of Streptococcus mutans and Streptococcus sobrinus, which may reduce enamel demineralization and the risk of white spot lesion formation.