9 December 2014 in Monthly Notices of the Royal Astronomical Society
We compute structure functions and Fourier spectra of 2D centroid velocity maps in order to study the gas dynamics of typical molecular clouds in numerical simulations. We account for a simplified treatment of time-dependent chemistry and the non-isothermal nature of the gas and use a 3D radiative transfer tool to model the CO line emission in a post-processing step. We perform simulations using three different initial mean number densities of n0 = 30, 100 and 300 cm−3 to span a range of typical values for dense gas clouds in the solar neighbourhood. We compute slopes of the centroid velocity increment structure functions (CVISF) and of Fourier spectra for different chemical components: the total density, H2 number density, 12CO number density as well as the integrated intensity of 12CO (J = 1 → 0) and 13CO (J = 1 → 0). We show that optical depth effects can significantly affect the slopes derived for the CVISF, which also leads to different scaling properties for the Fourier spectra. The slopes of CVISF and Fourier spectra for H2 are significantly steeper than those for the different CO tracers, independent of the density and the numerical resolution. This is due to the larger space-filling factor of H2 as it is better able to self-shield in diffuse regions, leading to a larger fractal co-dimension compared to CO.
1 January 2025 in Indoor Air
Ventilation effectiveness evaluates the performance of ventilation systems by assessing air exchange and contaminant removal. Optimising ventilation effectiveness in mechanical ventilation systems reduces the required supply airflow rate while maintaining adequate indoor air quality. This review clarifies inconsistent definitions of ventilation effectiveness in standards and literature and provides a comprehensive overview of terms, definitions, and relevant parameters. The review also analyses the influence of variable and building‐fixed parameters on ventilation effectiveness using data from selected studies. Contaminant position and supply/exhaust position had the greatest impact on ventilation effectiveness, with maximum absolute changes of 2.1 and 0.94, respectively. Variable parameters, such as air change rate and temperature difference, showed moderate mean absolute changes of 0.28 and 0.15 but significant maximum deviations of 0.85 and 0.4. Building‐fixed parameters, including room size and aspect ratio, showed the least influence, with mean absolute changes below 0.1. These results highlight the importance of parameter interactions, such as short‐circuit flows caused by higher air velocities. In EN 16798‐1:2022, design values for required airflow are based on a ventilation effectiveness of 1. However, the analysis shows large variations around this value, indicating potential deficits in air quality and opportunities for energy savings. This review highlights the need for holistic system design and consideration of parameter interactions to optimise energy efficiency and air quality.