1 May 2013 in Journal of Instrumentation
5 February 2026 in The European Physical Journal C
The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ FWHM at the $$Q_{\beta \beta }$$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ and $$118\hbox { V cm}^{-1}$$ , respectively. Alpha decays from the $$^{222}$$ Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.
15 July 2025 in Journal of High Energy Physics
A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ and $$ \overline{T_1} $$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.
24 July 2025 in Physical Review Research
This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first prototype optimized to maximize light collection using high photodetection efficiency (PDE), VUV-sensitive sensors and to minimize time fluctuations. We report a coincidence time resolution of 281 ± 2 ps FWHM, obtained using a Na 22 calibration source. This result is competitive with the current state-of-the-art PET scanners and represents a significant step forward in the development of liquid xenon as a viable alternative to conventional scintillators in PET technology.
28 August 2025 in The European Physical Journal C
We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ and $$181.39\pm {0.28}$$ times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and .
11 May 2026 in Physical Review Research
We report on a measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection and uses state-of-the-art, high-PDE (photodetection efficiency), VUV-sensitive silicon photomultipliers. We find a value of 3.7 % ± 0.4 % at 511 keV, once saturation effects are corrected for, a result close to the Poissonian resolution that we expect in our setup ( 2.8 % ± 0.4 % at 511 keV). Our results in the intrinsic resolution ( 2.3 % ± 0.8 % ) are compatible, within errors, at 511 keV, with those found by theoretical estimations that have been standing for the last 20 years, 1.8 % . Our work opens possibilities for apparatus based on liquid xenon and using scintillation only. In particular, it suggests that modular scintillation detectors using liquid xenon can be very competitive as building blocks in segmented calorimeters, with applications to Positron Emission Tomography technology.