Francesca Fiorini

Francesca Fiorini

Auto-generated profile, based on publicly available information

Francesca Fiorini

CRUK and MRC Oxford Institute for Radiation Oncology, Old Road Campus Research Building, Off Roosevelt Drive, University of Oxford , Oxford, OX3 7DQ , UK

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in AIP Advances
Verified
Journal Article
Open access
PDF file
DDDomenico Doria
Domenico Doria
KKK. F. Kakolee
K. F. Kakolee
Satyabrata KarSatyabrata Kar
Satyabrata Kar
SLS. K. Litt
S. K. Litt
FFF. Fiorini
F. Fiorini
MBM. Borghesi
M. Borghesi
The ultrashort duration of laser-driven multi-MeV ion bursts offers the possibility of radiobiological studies at extremely high dose rates. Employing the TARANIS Terawatt laser at Queen's University, the effect of proton irradiation at MeV-range energies on live cells has been investigated at dose rates exceeding 109 Gy/s as a single exposure. A clonogenic assay showed consistent lethal effects on V-79 live cells, which, even at these dose rates, appear to be in line with previously published results employing conventional sources. A Relative Biological Effectiveness (RBE) of 1.4±0.2 at 10% survival is estimated from a comparison with a 225 kVp X-ray source.

1 May 2014 in Physica Medica
Verified
Journal Article
Open access
PBPaul Bolton
Paul Bolton
MBM. Borghesi
M. Borghesi
CBC. Brenner
C. Brenner
DCD.C. Carroll
D.C. Carroll
CMC. De Martinis
C. De Martinis
JWJ.J. Wilkens
J.J. Wilkens
Suitable instrumentation for laser-accelerated proton (ion) beams is critical for development of integrated, laser-driven ion accelerator systems. Instrumentation aimed at beam diagnostics and control must be applied to the driving laser pulse, the laser-plasma that forms at the target and the emergent proton (ion) bunch in a correlated way to develop these novel accelerators. This report is a brief overview of established diagnostic techniques and new developments based on material presented at the first workshop on 'Instrumentation for Diagnostics and Control of Laser-accelerated Proton (Ion) Beams' in Abingdon, UK. It includes radiochromic film (RCF), image plates (IP), micro-channel plates (MCP), Thomson spectrometers, prompt inline scintillators, time and space-resolved interferometry (TASRI) and nuclear activation schemes. Repetition-rated instrumentation requirements for target metrology are also addressed.

1 June 2014 in Physica Medica
Verified
Journal Article
Closed access
FFF. Fiorini
F. Fiorini
DKD. Kirby
D. Kirby
JTJ. Thompson
J. Thompson
SGS. Green
S. Green
DPDavid Parker
David Parker
Mark HillMark Hill
Mark Hill

18 October 2011 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
FFF Fiorini
F Fiorini
DKD Kirby
D Kirby
MBM Borghesi
M Borghesi
DDDomenico Doria
Domenico Doria
JJJ C G Jeynes
J C G Jeynes
SGS Green
S Green
Laser-driven proton and ion acceleration is an area of increasing research interest given the recent development of short pulse-high intensity lasers. Several groups have reported experiments to understand whether a laser-driven beam can be applied for radiobiological purposes and in each of these, the method to obtain dose and spectral analysis was slightly different. The difficulty with these studies is that the very large instantaneous dose rate is a challenge for commonly used dosimetry techniques, so that other more sophisticated procedures need to be explored. This paper aims to explain a method for obtaining the energetic spectrum and the dose of a laser-driven proton beam irradiating a cell dish used for radiobiology studies. The procedure includes the use of a magnet to have charge and energy separation of the laser-driven beam, Gafchromic films to have information on dose and partially on energy, and a Monte Carlo code to expand the measured data in order to obtain specific details of the proton spectrum on the cells. Two specific correction factors have to be calculated: one to take into account the variation of the dose response of the films as a function of the proton energy and the other to obtain the dose to the cell layer starting from the dose measured on the films. This method, particularly suited to irradiation delivered in a single laser shot, can be applied in any other radiobiological experiment performed with laser-driven proton beams, with the only condition that the initial proton spectrum has to be at least roughly known. The method was tested in an experiment conducted at Queen’s University of Belfast using the TARANIS laser, where the mean energy of the protons crossing the cells was between 0.9 and 5 MeV, the instantaneous dose rate was estimated to be close to 109 Gy s−1 and doses between 0.8 and 5 Gy were delivered to the cells in a single laser shot. The combination of the applied corrections modified the initial estimate of dose by up to 40%.

8 April 2011 in Laser and Particle Beams
Verified
Journal Article
Closed access
PDF file
DKD. Kirby
D. Kirby
SGS. Green
S. Green
FFF. Fiorini
F. Fiorini
DPDavid Parker
David Parker
LRL. Romagnani
L. Romagnani
HPHugo Palmans
Hugo Palmans
A new approach to spectroscopy of laser induced proton beams using radiochromic film (RCF) is presented. This approach allows primary standards of absorbed dose-to-water as used in radiotherapy to be transferred to the calibration of GafChromic HD-810 and EBT in a 29 MeV proton beam from the Birmingham cyclotron. These films were then irradiated in a common stack configuration using the TARANIS Nd:Glass multi-terawatt laser at Queens University Belfast, which can accelerate protons to 10–12 MeV, and a depth-dose curve was measured from a collimated beam. Previous work characterizing the relative effectiveness (RE) of GafChromic film as a function of energy was implemented into Monte Carlo depth-dose curves using FLUKA. A Bragg peak (BP) “library” for proton energies 0–15 MeV was generated, both with and without the RE function. These depth-response curves were iteratively summed in a FORTRAN routine to solve for the measured RCF depth-dose using a simple direct search algorithm. By comparing resultant spectra with both BP libraries, it was found that the effect of including the RE function accounted for an increase in the total number of protons by about 50%. To account for the energy loss due to a 20 µm aluminum filter in front of the film stack, FLUKA was used to create a matrix containing the energy loss transformations for each individual energy bin. Multiplication by the pseudo-inverse of this matrix resulted in “up-shifting” protons to higher energies. Applying this correction to two laser shots gave further increases in the total number of protons, N of 31% and 56%. Failure to consider the relative response of RCF to lower proton energies and neglecting energy losses in a stack filter foil can potentially lead to significant underestimates of the total number of protons in RCF spectroscopy of the low energy protons produced by laser ablation of thin targets.

20 November 2019 in British Journal of Radiology
Verified
Journal Article
Closed access
STSuliana Teoh
Suliana Teoh
FFFrancesca Fiorini
Francesca Fiorini
BGBen George
Ben George
Kate VallisKate Vallis
Kate Vallis
FHFrank Van den Heuvel
Frank Van den Heuvel
Objective: To identify a subgroup of lung cancer plans where the analytical dose calculation (ADC) algorithm may be clinically acceptable compared to Monte Carlo (MC) dose calculation in intensity modulated proton therapy (IMPT). Methods: Robust-optimised IMPT plans were generated for 20 patients to a dose of 70 Gy (relative biological effectiveness) in 35 fractions in Raystation. For each case, four plans were generated: three with ADC optimisation using the pencil beam (PB) algorithm followed by a final dose calculation with the following algorithms: PB (PB-PB), MC (PB-MC) and MC normalised to prescription dose (PB-MC scaled). A fourth plan was generated where MC optimisation and final dose calculation was performed (MC-MC). Dose comparison and γ analysis (PB-PB vs PB-MC) at two dose thresholds were performed: 20% (D20) and 99% (D99) with PB-PB plans as reference. Results: Overestimation of the dose to 99% and mean dose of the clinical target volume was observed in all PB-MC compared to PB-PB plans (median: 3.7 Gy(RBE) (5%) (range: 2.3 to 6.9 Gy(RBE)) and 1.8 Gy(RBE) (3%) (0.5 to 4.6 Gy(RBE))). PB-MC scaled plans resulted in significantly higher CTVD2 compared to PB-PB (median difference: −4 Gy(RBE) (−6%) (-5.3 to −2.4 Gy(RBE)), p ≤ .001). The overall median γ pass rates (3%–3 mm) at D20 and D99 were 93.2% (range:62.2–97.5%) and 71.3 (15.4–92.0%). On multivariate analysis, presence of mediastinal disease and absence of range shifters were significantly associated with high γ pass rates. Median D20 and D99 pass rates with these predictors were 96.0% (95.3–97.5%) and 85.4% (75.1–92.0%). MC-MC achieved similar target coverage and doses to OAR compared to PB-PB plans. Conclusion: In the presence of mediastinal involvement and absence of range shifters Raystation ADC may be clinically acceptable in lung IMPT. Otherwise, MC algorithm would be recommended to ensure accuracy of treatment plans. Advances in knowledge: Although MC algorithm is more accurate compared to ADC in lung IMPT, ADC may be clinically acceptable where there is mediastinal involvement and absence of range shifters.