1 January 2020 in Journal of Medical Imaging
<!-- *** Custom HTML *** --> We are developing automated analysis of corneal-endothelial-cell-layer, specular microscopic images so as to determine quantitative biomarkers indicative of corneal health following corneal transplantation. Especially on these images of varying quality, commercial automated image analysis systems can give inaccurate results, and manual methods are very labor intensive. We have developed a method to automatically segment endothelial cells with a process that included image flattening, U-Net deep learning, and postprocessing to create individual cell segmentations. We used 130 corneal endothelial cell images following one type of corneal transplantation (Descemet stripping automated endothelial keratoplasty) with expert-reader annotated cell borders. We obtained very good pixelwise segmentation performance (e.g., Dice coefficient = 0.87 ± 0.17, Jaccard index = 0.80 ± 0.18, across 10 folds). The automated method segmented cells left unmarked by analysts and sometimes segmented cells differently than analysts (e.g., one cell was split or two cells were merged). A clinically informative visual analysis of the held-out test set showed that 92% of cells within manually labeled regions were acceptably segmented and that, as compared to manual segmentation, automation added 21% more correctly segmented cells. We speculate that automation could reduce 15 to 30 min of manual segmentation to 3 to 5 min of manual review and editing.
1 August 2024 in Translational Vision Science & Technology
Purpose: To determine endothelial cell density (ECD) from real-world donor cornea endothelial cell (EC) images using a self-supervised deep learning segmentation model. Methods: Two eye banks (Eversight, VisionGift) provided 15,138 single, unique EC images from 8169 donors along with their demographics, tissue characteristics, and ECD. This dataset was utilized for self-supervised training and deep learning inference. The Cornea Image Analysis Reading Center (CIARC) provided a second dataset of 174 donor EC images based on image and tissue quality. These images were used to train a supervised deep learning cell border segmentation model. Evaluation between manual and automated determination of ECD was restricted to the 1939 test EC images with at least 100 cells counted by both methods. Results: The ECD measurements from both methods were in excellent agreement with rc of 0.77 (95% confidence interval [CI], 0.75–0.79; P < 0.001) and bias of 123 cells/mm2 (95% CI, 114–131; P < 0.001); 81% of the automated ECD values were within 10% of the manual ECD values. When the analysis was further restricted to the cropped image, the rc was 0.88 (95% CI, 0.87–0.89; P < 0.001), bias was 46 cells/mm2 (95% CI, 39–53; P < 0.001), and 93% of the automated ECD values were within 10% of the manual ECD values. Conclusions: Deep learning analysis provides accurate ECDs of donor images, potentially reducing analysis time and training requirements. Translational Relevance: The approach of this study, a robust methodology for automatically evaluating donor cornea EC images, could expand the quantitative determination of endothelial health beyond ECD.
18 June 2024 in Journal of Biomedical Optics
Peripheral neuromodulation is a growing area of research that involves the application of external stimuli to modulate nerve activity.1 Although these methods have been applied to treat various disease conditions, the effectiveness of these therapies has been limited. For instance, vagus nerve stimulation (VNS) is a clinically approved therapy to treat conditions such as drug-resistant epilepsy,2 depression,3 and obesity.4 However, therapeutic efficacy with this method is just moderate, with 50% of patients seeing a significant () reduction in seizure frequency after 1 year of implantation.5 In addition, several trials involving VNS therapy have failed to reach clinical endpoints.6,7 We find that computational modeling approaches can aid researchers to test various interface designs and identify ideal stimulation parameters (pulse amplitude, width, duty cycle, etc.); these could serve to improve fiber selectivity and thereby increase therapeutic efficacy. However, these models require accurate anatomical information about human nerve morphology since the latter significantly affects optimal stimulation parameters.8 Therefore, there is a need for methods that enable visualization and mapping of human peripheral nerves to improve computational models, providing a deeper understanding of nerve responses to neuromodulation therapies and enhancing treatment outcomes.
1 January 2024 in Journal of Medical Imaging
PurposeTo create Guided Correction Software for informed manual editing of automatically generated corneal endothelial cell (EC) segmentations and apply it to an active learning paradigm to analyze a diverse set of post-keratoplasty EC images.ApproachAn original U-Net model trained on 130 manually labeled post-Descemet stripping automated endothelial keratoplasty (EK) images was applied to 841 post-Descemet membrane EK images generating “uncorrected” cell border segmentations. Segmentations were then manually edited using the Guided Correction Software to create corrected labels. This dataset was split into 741 training and 100 testing EC images. U-Net and DeepLabV3+ were trained on the EC images and the corresponding uncorrected and corrected labels. Model performance was evaluated in a cell-by-cell analysis. Evaluation metrics included the number of over-segmentations, under-segmentations, correctly identified new cells, and endothelial cell density (ECD).ResultsUtilizing corrected segmentations for training U-Net and DeepLabV3+ improved their performance. The average number of over- and under-segmentations per image was reduced from 23 to 11 with the corrected training set. Predicted ECD values generated by networks trained on the corrected labels were not significantly different than the ground truth counterparts (p=0.02, paired t-test). These models also correctly segmented a larger percentage of newly identified cells. The proposed Guided Correction Software and semi-automated approach reduced the time to accurately segment EC images from 15 to 30 to 5 min, an ∼80% decrease compared to manual editing.ConclusionsGuided Correction Software can efficiently label new training data for improved deep learning performance and generalization between EC datasets.